478494
129
Verklein
Vergroot
Pagina terug
1/168
Pagina verder
VX-8GR/GE OPERATING MANUAL 127
SET MODE
50: MEMORY SKIP
51: MEMORY WRITE
52: MESSAGE LIST
53: MESSAGE REGISTER
54: MESSAGE SELECT
55: MIC GAIN
56: MONI/T-CALL
57: MUTE
58: OFF TIMER
59: ON TIMER
60: OPENING MESSAGE
61: PAGER ANS-BACK
62: PAGER CODE-RX
63: PAGER CODE-TX
64: PASSWORD
65: PR FREQUENCY
66: PRI REVERT
67: PRI TIME
68: PTT DELAY
69: RPT ARS
70: RPT SHIFT
71: RPT SHIFT FREQ
72: RX MODE
73: SAVE RX
74: SAVE TX
75: SCAN LAMP
76: SCAN RE-START
77: SCAN RESUME
78: SENSOR DISPLAY
79: SENSOR INFO
80: SET MODE CSR
81: SET MODE FORMAT
82: SMART SEARCH
83: S-METER SYMBOL
84: SPEC-ANALYZER
85: SQL LEVEL
86: SQL S-METER
87: SQL SPLIT
88: SQL TYPE
89: STEP FREQUENCY
90: TIME SET
91: TONE FREQUENCY
92: TONE-SRCH MUTE
93: TONE-SRCH SPEED
94: TOT
95: VFO MODE
96: VFO SKIP
97: VIBRATOR
98: VIBRATOR MODE
99: VOLUME MODE
100: WX ALERT
Selects the Memory Scan channel-selection mode.
Determines the method of selecting channels for Memory Storage.
Programming a Member List for the Message feature.
Selects your Personal ID for the Message feature.
Programming a Message for the Message feature.
Adjusts the microphone gain level.
Selects the MONI/T.CALL key (just below the PTT switch) function.
Adjusts the receiver audio output level when the MUTE function was activated.
Set the OFF Timer time.
Set the ON Timer time.
Selects the Opening Message that appears when the radio is powered on.
Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch.
Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Programming and activating the Password feature.
Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder.
Enables/Disables the Priority Revert feature.
Selects the time between the Priority (Dual Watch) channel checks, when the feature is
active.
Selects the time delay before the carrier is transmitted, when the PTT switch is pressed.
Enables/Disables the Automatic Repeater Shift function.
Sets the Repeater Shift Direction.
Sets the magnitude of the Repeater Shift.
Sets the receiving mode.
Selects the Receive-mode Battery Saver interval (“sleep” ratio).
Enables/Disables the Transmitter Battery Saver.
Enables/Disables the Scan Lamp (while scanner is paused).
Selects the Scan Re-start Delay time.
Selects the Scan Resume mode.
Selects the sensor information when the transceiver is operating in the “Mono” band mode
with large characters.
Indicates the Information of the internal sensors.
Selects the Set Mode Cursor.
Selects the display format of the Set Mode operation.
Selects the Smart Search Sweep mode.
Selects the S- & TX PO meter Symbol.
Selects the Spectrum Analyzer sweep mode.
Sets the Squelch threshold level.
Adjusts the Squelch threshold level to the S-meter level.
Enables/disables split CTCSS/DCS coding.
Selects the Tone Encoder and/or Decoder mode.
Setting of the DIAL frequency steps.
Sets the Clock time.
Setting of the CTCSS Tone Frequency.
Enables/Disables the receiver audio output while the Tone Search Scanner is activated.
Selects the Tone Search Scanner speed.
Setting of the TOT time.
Selects or disables the VFO band edge limiting for the current band.
Setting My Band.
Enables/Disables the Vibrator function.
Selects the vibration mode of the Vibrator function.
Select the
[
VOL
]
key function.
Enables/Disables the Weather Alert Feature.
OFF / SKIP / ONLY
NEXT / LOWER
--
--
--
LEVEL 1 ~ LEVEL 9
(
LEVEL 5
)
MONI / T-CALL
1
MUTE 30%, MUTE 50%,
MUTE 100%, or OFF
--
--
NORMAL / OFF / DC / MESSAGE
ON / OFF
--
--
--
300Hz ~ 3000Hz (1000Hz/step)
(
1600Hz
)
ON / OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step)
(
5.0sec
)
OFF / 20ms / 50ms / 100ms / 200ms
ON / OFF
SIMPLEX / -RPT / +RPT
0.000MHz ~ 150.000MHz (50 kHz/step)
2
AUTO / NFM / AM
0.2sec ~ 0.9sec (0.1sec/step),
1.0sec ~ 9.5sec (0.5sec/step), or
10.0sec ~ 60.0sec (5sec/step)
ON / OFF
ON / OFF
0.1sec ~ 0.9sec (0.1sec/step) or
1.0sec ~ 10.0sec (0.5sec/step)
(
2.0sec
)
2.0sec ~ 10.0sec (0.5sec/step) /BUSY /
HOLD
(
5.0sec
)
DC / TEMP / OFF
--
Nine patterns
LIST / ITEM
SINGLE / CONTINUOUS
Four patterns
1Time / CONTINUOUS / Full Time
LEVEL 0 ~ LEVEL 15
(
LEVEL 1
)
OFF / LEVEL 0 ~ LEVEL 9
OFF / ON
OFF / TONE / TONE SQL / DCS /
REV TONE / PR FREQ / PAGER / MESSAGE
AUTO / 5.0 / 6.25 / 8.33 / 10.0 / 12.5 / 15.0 /
20.0 / 25.0 / 50.0 / 100.0 kHz
--
50 standard CTCSS tones
(
100.0Hz
)
ON / OFF
FAST (2.5 tone/sec) / SLOW (1.25 tone/sec)
OFF / 0.5min ~ 10.0min (0.5min/step)
(
3.0min
)
ALL / BAND
--
OFF / BUSY / SIGNALING
MODE1 / MODE2 / MODE3
NORMAL / AUTO BACK
ON / OFF
SET MODE ITEM FUNCTION
AVAILABLE VALUES
(
DEF ALT: UNDERLINED BOLD
)
1: Depends on the transceiver version.
2: Depends on the operating band and transceiver version.
129

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Yaesu VX-8GE bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Yaesu VX-8GE in de taal/talen: Engels als bijlage per email.

De handleiding is 4,19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info