Installation regulations
Greenstar Danesmoor Utility 2022+ and Utility System 2022+ - 6 721 846 263 (2022/01) 5
2 Installation regulations
2.1 Complying with the building regulations
This heating appliance forms part of the controlled services for the
building. It is law that all controlled services for buildings must comply
with building regulations. You must be able to satisfy your Local
Authority Building Control Body (LABC) that the work carried out
concerning the installation and commissioning of this heating appliance
has been carried out to a satisfactory standard.
OFTEC operate a competent persons scheme and registered installers
are able to certify that their work complies with building regulations.
Under the scheme;
OFTEC must be informed about every installation.
OFTEC will issue a building regulations compliance certificate to the
householder and will notify the LABC.
OFTEC provide controlled document forms CD10 and CD11 for use
during installation and commissioning respectively.
Other organisations operate self-certification schemes e.g. NAPIT and
BESCA Ltd. and it may be possible for installers who are members of
these organisations to self certify their work.
Alternatively you must submit a building control notice to the LABC
before installing any boiler. The LABC will then arrange regular
inspection visits during the work to ensure that the installation complies
with the regulations.
Installation
Failure to install appliances correctly could lead to prosecution.
The appliance should be installed by a competent person. The person
installing the appliance should be aware of the Health and Safety at Work
Act and take appropriate action to ensure that the regulations are
adhered to. In order to give optimum efficiency and trouble free
operation the appliance must be commissioned by a qualified OFTEC
engineer.
The compliance with a British Standard does not, in itself, confer
immunity from legal obligations. In particular the installation of this
appliance must be in accordance with the relevant requirements of the
following British Standards and regulations in respect of the safe
installation of equipment:
BS 5410: part 1: Code of practice for Liquid Fuelled Boilers.
BS 799: part 5: Specification for Oil Storage Tanks.
BS 7593: Code of Practice for treatment of water in domestic
hot water central heating systems.
BS 5449: part 1: Specification for forced circulation hot water central
heating for domestic premises.
BS 5955: part 8: Specification for the installation of thermoplastic
pipes and associated fittings for use in domestic hot
and cold water services and heating systems.
BS 7291: Thermoplastic pipes and associated fittings for hot
and cold water for domestic purposes and heating
installations in buildings.
BS 7074: part 1: Application, selection and installation of expansion
vessels and ancillary equipment for sealed water
systems.
BS 1254-2: Copper and copper alloys plumbing fittings part 2:
Fittings with compression ends for use with copper
tubes.
BS 7671: IET Wiring Regulations, current edition.
BS 1362: Specification for general purpose fuse links for
domestic and similar purposes.
BS EN 12828 Heating systems in buildings. Design for water-
based heating systems.
The Building Regulations Part G, Part J and L1 England and Wales; Part
F, Part G and Part J Section III Scotland; Part L and Part F Northern
Ireland.
Local water company bye-laws.
The Control of Pollution (Oil) Regulations.
OFTEC Standards.
Where no specific instruction is given, reference should be made to the
relevant codes of practice.
Installations in Eire (Republic of Ireland)
The Installation must be performed by a competent and suitably trained
person in accordance with the following Eire regulations.
Current Building Regulations - Republic of Ireland
ETCI rules for electrical installation
For further guidance see:
OFTEC Technical book three - Regional requirements: Republic of
Ireland
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System in de taal/talen: Engels als bijlage per email.

De handleiding is 14.85 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info