Operation
6720813171 (2016/05) 33
“Chimney sweep” button
The “Chimney sweep” button ([3] is used to put the boiler into flue gas
test, service or manual operation mode.
The flue gas test enables the boiler to be run in full-load operation
manually for a short period. See table 10, “Flue gas test”, page 34.
The service mode enables the boiler to be run in part-load operation
manually for a short period. Measurements and settings are carried out
on the boiler during service mode. ( table 11, “Service mode”,
page 34).
Manual operation mode enables the boiler to be operated manually for a
long period. The boiler is switched to manual mode when the control
system has not been installed yet or is out of order ( table 12, “Manual
operation”, page 35).
A maximum heating water temperature in accordance with the setting of
the “Maximum heating water temperature” dial [8] on the BC 10 basic
controller applies during chimney sweep, service and manual operation.
“Service” button
The “Service” button [4] is used to display the current CH flow
temperature, the current system pressure etc. Also see table 22, “BC10
Display readings”, page 53, table 23, “BC10 Display settings”, page 54
and table 24, “BC10 Display codes”, page 54.
Service Tool connection
This service connection is for Worcester service engineers only.
“Burner” (On/Off) LED
The “Burner” (On/Off) LED ( fig. 69, [6]) lights up when the burner of
the boiler is active and it is extinguished when the burner is switched off.
The “Burner” (On/Off) LED indicates the burner status.
“Heat demand” LED
The “Heat demand”LED ( fig. 69, [7]) lights up when the control
system has made a heat demand and it is extinguished when this heat
demand is no longer required.
Maximum CH (boiler) flow temperature dial
The maximum CH (boiler) flow temperature ( fig. 69, [8]) is used to
set the upper CH (boiler) flow temperature limit. The unit is °C.
Display
The heating system display values, display settings and display codes
can be read out from the display ( fig. 69, [9]). If a fault occurs the
display will immediately show the accompanying fault code. The fault
code display will flash if a locking fault is detected.
“DHW mode” LED
The “DHW mode” LED ( fig. 69, [10]) lights up when a DHW request
has occurred and it is extinguished when this DHW request is no longer
required.
DHW temperature dial (Only functional when used in conjunction
with Bosch controllers)
The DHW temperature dial ( fig. 69, [11]) is used to select the
required temperature of the hot water in the hot water cylinder.
The unit is °C ( table 18, page 44).
9.2 BC10 control operating instructions
You can navigate through the menu structure of the boiler on the BC10
using the “Reset” button, the “Chimney sweep” button, the “Service
button” ( fig. 69, items 2, 3 and 4) and the display ( fig. 69, [9])
using table 9 to table 13.
The menu structure consists of 5 menus:
Normal Operation menu
Flue Gas Test menu
Service Mode menu
Manual Operation menu
Settings menu.
WARNING:
Damage to the installation with underfloor heating: by
the floor being overheated.
Limit the maximum CH flow temperature using the
“Maximum CH flow temperature” dial [8] to the
maximum flow temperature of the floor heating
circuit (usually maximum 40 °C).
WARNING:
Damage to the installation due to frost while manual
operation is switched on. After a power failure or after
switching off the supply voltage, the heating system may
freeze since manual operation is no longer active then.
Start manual operation after switching on the heating
system, so that the system is permanently in
operation (especially if there is a risk of freezing).
LED Status Explanation
On Burner
operational
Boiler water is being heated.
Off Burner off The CH (boiler) flow temperature has
reached the set temperature or there is no
heat demanded.
Table 8 Meanings of “Burner” (On/Off) LED indications
Normal operation menu
Step 1 [\/2/4| Display value. Currently measured CH flow temperature in °C. Also see section 14.2, page 53.
Step 2 Continue in Normal operation menu? Yes: step 3
No: step 1
Step 3 Press the e button.
Step 4 [p/1.6| Display value. Currently measured system pressure in bar. Also see section 14.2, page 53.
Step 5 Press the e button.
Step 6 [-/h/\| Random display code. In this case: Operating phase: Boiler in heating mode. Also see section 14.3, page 54.
Step 7 Have at least 5 seconds passed without a button being pressed and/or has the mains voltage been interrupted? Yes: step 1
No: step 8
Step 8 Press the e button. step 1
Table 9 Normal operation
33

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Worcester-Bosch GB162-80 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Worcester-Bosch GB162-80 in de taal/talen: Engels als bijlage per email.

De handleiding is 5,43 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installatiehandleiding - English - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info