SERIAL NUMBER
Your boiler serial number and model number should always
be quoted in any contact with Worcester Heat Systems. This will
help identify spare parts and also avoid confusion and delays
during any service call-out. You will find these numbers on top of
the electrical control box cover plate, and access can be gained by
removing the top panel of the boiler casing.
TECHNICAL INFORMATION
Worcester Danesmoor oil-fired pressure-jet boilers can
provide both domestic hot water and full central heating, with
outputs ranging from 12kW to 70kW (40,000 to 240,000 Btu/h).
Domestic hot water must be supplied via a conventional indirect
hot-water system, utilising an indirect double-feed cylinder.
All standard Danesmoor boilers are supplied without a
circulating pump, but there is provision to locate the pump within
the boiler casing. All models are supplied pre-wired and may be
fitted with a facia mounted programmer (sold separately).
(See Fig. 1.)
(a) Switch on the electrical mains supply to the boiler and the
POWER ON lamp in the control facia will light up.
(b) Ensure that any external controls connected to the boiler, such
as a room thermostat, are on a high setting.
(c) If a programmer is fitted, set it to the correct time of day and
position the selectors to ON.
HOW TO START YOUR
BOILER
Fig. 1. Control Facia
Temperature Control Knob
Lockout Indicator Light
Mains Power Indicator Light Optional Programmer
4