809217
3
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
The Worcester
350
is
a combination boiler which will supply
mains fed domestic hot water plus central heating
at
an
output
of
between 9.0 and 25
kW.
HOT
WATER
PROVISION
When a
tap
is
turned
on
the appliance
will
begin
to
operate. Hot
water
will
become available
at
the tap
in
a continuous supply
at
a
constant
temperature, after a short delay, depending
on
when
the
appliance was last fired. The fan
will
continue to run
for
a few
seconds after the tap has been turned
off,
to remove any residual
heat from the appliance.
CENTRAL
HEATING
AND
HOT
WATER
PROVISION
A
demand
for
hot water
will
take priority over the supply of
heat
to
the
central heating system. The
burner
will
remain
off for
approximately three minutes after the demand
for
hot
water
is
completed
before
automatically
returning to
central
heating
operation.
CENTRAL
HEATING
PROVISION
When a demand
is
made
for
central heating the burner
will
light
at
its minimum
output
before rising to
the
preset
maximum
output. The appliance
will
then automatically
match
output
to
the
system load.
In
the event of
the
system requiring less
than
9
l<W,
the
burner will light only periodically
to
maintain
system
temperature.
When
the
automatic
controls close
the
burner
down, the fan
will
continue to operate
for
a
few
seconds.
The
appliance
Serial
Number
must
be
quoted
in
any
correspondence.
It
will
comprise
C350RSF
and a 1 0-digit number.
It can be seen through the lower opening
in
the inner cover panel
accessible
by
removing the cabinet front panel.
CENTRAL HEATING
AND
HOT
WATER
PROGRAMME
CONTROL
Your
Worcester
350
is
fitted with either a 3-position Operating
Switch or
an
Electronic Programmer
on
the
facia panel for
the
control of domestic hot water and central heating.
OPERATING
SWITCH
The switch offers the following positions:
WATER
The
appliance
will
provide
hot
water
when a tap or shower
is
turned on.
OFF
Both
the
central heating
and
domestic
hot
water
will
remain
off.
HEATING
&
WATER
The
central~heating
will
operate
in
response
to
any
system
controls
and
domestic hot water
will
be supplied when
a tap or shower
is
turned on.
ELECTRONIC
PROGRAMMER
Your
Installer
may
have
mounted
the
optional
electronic
programmer
on
the appliance facia panel.
For
full
details
on
how
to
operate
the
Programmer
please
refer
to
the
Operating
Instructions which are supplied with the Programmer.
CENTRAL
HEATING
TEMPERATURE
CONTROL
The
temperature control knob
on
the facia panel allows control
of the water temperature to the radiators.
INDICATOR
LIGHTS
There are three indicator lights
on
the
facia panel.
The
red light when
on
indicates
that
the system pressure
is
too
low (see System Operation). The amber light when
on
indicates
that
the
mains electricity to
the
appliance
is
on.
The
green light
when
on
indicates
that
the
appliance
is
supplying
either
domestic hot water or central heating.
PRESSURE
GAUGE
A
pressure
gauge
is
located
on
the
facia
panel.
The
green
pressure needle
has
been
preset
to
show
the
water
pressure
which is required for
the
appliance to operate effectively. The
white pressure needle
will
show
the
amount
of water pressure
in
your particular system.
If
the
pressure drops below the required
minimum
pressure
the
red
indicator
will light. For remedial
action please refer to System Operation.
By
slightly reducing the flow of domestic hot water from the tap,
the temperature of the
water
will increase. This
is
of particular
advantage
in
the
winter, for
example
to increase
bath
water
temperature and to remove heavy grease deposits
on
plates, etc.
Also
this
will
provide an
added
advantage of reducing
the
delay
before
hot
water
is
obtained.
The
maximum discharge temperature of hot water to the taps
is
preset
at
the factory.
TO
LIGHT
THE
APPLIANCE
Make sure
that
the appliance is off by:
(a)
Positioning the Operating Switch or Programmer to
OFF.
(b)
Switching
the
mains electricity
off.
Turn
the gas service cock
on
and
check
that
all
the water valves
to
the
central heating
supply
are open. Check
that
the
white
needle
on
the pressure gauge
is
not
below the required pressure.
See
Fig.
1.
Switch
on
the
mains
electricity
and
turn
the
central
heating
temperature control knob to max. Set the Operating Switch
(or
Programmer) to
HEATING
&
WATER.
This will light
the
main
burner.
The
burner
can
be
seen
through
the
sightglass
which
is
accessible by removing
the
cabinet front panel.
To
remove the
panel, pull it away
at
the
bottom
and
lift
it
off
the
top support.
Set
the
Operating
Switch
(or
Programmer)
to
the
required
position.
If
a room thermostat
is
fitted to
the
system,
set
to
the
desired
temperature. Set the central heating temperature control knob to
the required position.
FAILURE
TO
LIGHT
If
the
appliance fails to light
or
it locks our during operation,
switch
the
operating
switch
to
OFF
and
then
to
ON.
If
the
appliance fails to light after several
attempts
at
ignition check
the overheat thermostat by pressing the reset button.
In
the event
that
the problem continues call a Service Engineer.
TO
STOP
THE
APPLIANCE
For Short Periods
Set the Operating Switch (or programmer) to
OFF.
For Long Periods
Set the Operating Switch (or programmer) to
OFF.
Switch off the mains electricity. The facia mounted programmer
will retain its settings for
about
four weeks after which it
will
return to the factory
set
programme. The display
will
disappear
after approximately 12 hours.
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Worcester-Bosch 350 Combi bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Worcester-Bosch 350 Combi in de taal/talen: Engels als bijlage per email.

De handleiding is 1.77 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info