813085
31
Verklein
Vergroot
Pagina terug
1/83
Pagina verder
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 31 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/2007 Art. No. 950 281
Error code Cause of error
Desired
values How to correct error
TR =
Temperature at flue gas
fan
too low. Measuring point:
fan.
Sensor Pt 1000
Picture / case 1
Do not light! First empty
pot. See explanation on
the right.
Temperature sensor at flue gas fan
still too low after 21 minutes. Often
there are still unburnt pellets in the
burner pot.
Case 1: False start; burner pot filled
with pellets, no flame. temperature TR
is not reached
burner pot/appliance not cleaned
false start
negative pressure in installation
room (causes flow reversal in the
ignition system) false start (often
associated with flue gas escaping
from the appliance)
ignition cartridge defective false
start
TR 49 °C
TR Values
are sampled
continuously
starting 21
minutes after
the stove
start signal.
After restart
the first
sampling
again takes
place after
21 minutes.
Always empty and clean
burner pot before making a
new start. Note: Never empty
burner pot into fuel hopper –
danger of fire through
embers! Search for other
causes. Ensure sufficient
supply of combustion air.
Negative pressure in the
installation room, whether
caused by exhauster hood,
house ventilation system or
pneumatic conveyor systems,
is hazardous and must be
avoided. Observe country-
specific regulations and
separate technical information
included in the delivery. Then
do manual reset via I/O key.
Picture / case 2
Do not light! First empty
pot. See explanation on
the right.
Case 2: cause:
shutdown in mid
-
operation, because of too few pellets
in the fuel hopper or hopper has run
empty (only few pellets in the burner
pot)
Remedy in case 2: replenish
pellets, empty and clean
burner pot. Reset and start
anew.
Case 3:
no pellets in burner pot Case 3: cause: appliance has shut
down because ambient temperature is
too low + calorific output setting is too
low. Temperature remains below
desired TR during operation.
Remedy in case 3: increase
thermal output. Reset via I/O
key.
TP =
Temperature at pellet
chute too high
Measuring point: pellet
chute
Measuring sensor: Pt 1000
External error!
Possible causes include negative
pressure due to ventilation system or
exhauster hood or far too little
chimney draught with power failure
(fan).
TP < 200 °C
(only 6 kW
Airplus
appliances)
TP < 170 °C
(all other
appliances)
This is no hardware error!
Let appliance cool off until
TP falls below desired value.
Search for and correct
external cause. Only then do
manual reset via I/O key. See
above for more information on
negative pressure.
ST =
Temperature cutoff (STB)
has triggered.
Measuring point in
Waterplus appliances:
capillary sensor parallel to
FKY (measuring point for
TW) in heat exchanger
(mounted)
Measuring point in Airplus
appliances: capillary
sensor on heat reflector
plate of fuel hopper
Measuring sensor: STB
according to DIN 3440:
The
STB is an obligatory, self-
supporting safety comp-
onent with a control box of
its own that works indep-
endently of system control.
External error!
Temperature of boiler
or appliance too high. STB has
triggered because temperature is too
high (safety function). The cause is
almost always external, not due to the
appliance, since STB only triggers
when heat generated by the appliance
is not transmitted.
Possible causes:
Waterplus models: not properly
bled or operation without water or
with wrong connection to domestic
water system ( no / insufficient heat
transmission!!). Check external
hydraulics and external controls.
Airplus models: overheating.
Check convection inlets and
outlets. Reduce thermal output if
room temperature too high.
T
STB
95 °C
With
Waterplus
models the
current value
can be
determined
approx-
imately by
sampling TW
at menu level
1. Sampling
is not
possible with
Airplus
appliances.
This is no hardware error!
Let appliance cool off until
STB falls below desired
value. Search for and correct
external cause.
Only then release STB + do
manual reset via I/O key.
31

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Wodtke Frank waterplus S4 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Wodtke Frank waterplus S4 in de taal/talen: Duits als bijlage per email.

De handleiding is 3.18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Wodtke Frank waterplus S4

Wodtke Frank waterplus S4 Gebruiksaanwijzing - Deutsch - 76 pagina's

Wodtke Frank waterplus S4 Gebruiksaanwijzing - Français - 80 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info