813077
7
Verklein
Vergroot
Pagina terug
1/83
Pagina verder
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 7 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/2007 Art. No. 950 281
switches the Waterplus appliance off as soon as the set maximum room temperature has been
reached. This will reliably prevent the room of installation from overheating. In this case the
energy needed for the other rooms or for heating drinking water must be generated from
additional heat sources. This is usually achieved by means of a cascade connection with an
electric immersion heater or a oil or gas boiler. Then the auxiliary heat generator only starts up
automatically when the boiler of the Waterplus appliance is switched off. This means that the
base load is still borne by the boiler of the Waterplus appliance, while the other heat generators
only serve to meet demand peaks.
2.3 Minimum operating time / External controller settings
Pellets are a solid fuel which inherently require more time to ignite than do liquid or gaseous
fuels. After the start of ignition it can take a few minutes for the first flame to appear, and a total
of 15 minutes before the preheating programme is completed and the appliance has reached
its full thermal output. In contrast to oil or gas fuelled stoves it can also take a few minutes
after switching off the appliance until all the pellets in the burner pot have burnt down
and the flame goes out. This is why the fan of the appliance has been programmed to
continue running for several minutes after switching off the stove (display shows “G OFF”). You
should therefore wait until this fan after-run time is over before restarting the appliance.
When used with an external controller the appliance should therefore be allowed to run for a
minimum operating time of 30 or better still 60 minutes. This means that the controller must
be set in such a way that the stove’s operating (on-off) cycle does not become too short,
and its hysteresis should be sufficiently large to allow at least 15 minutes to pass from the
“off” to the “restart” signal to accommodate the fan after-run time.
2.4 Heat delivery to water with Waterplus appliances
The heat delivery to water during the operation of Waterplus appliances must be >1.6 kW at
minimum, since otherwise the installed safety devices will make the appliance go into
modulation mode or switch off. Typical signs of insufficient heat delivery to the water heating
system are modulation mode (indicated by “H.M” on the display), frequent switching between on
and off (accompanied by the message “TW OFF” on the display) or an error shutdown triggered
by the temperature cutoff (STB), (indicated by the message “ST”). This shows the importance of
thorough planning to ensure that the appliance is properly connected to the domestic water
system and its control system is properly configurated. The appliance must have a
continuous water throughflow of > 600 l/h, and the circulation pump and the length and flow
resistance of the connecting lines must be dimensioned accordingly. At a flow rate of 600 l/h the
appliance itself has a flow resistance of 130-140 mbar. Insufficient heat delivery to water
points to a problem with the hydraulic system, not with the appliance!
2.5 Room and ambient temperature and humidity during operation
All wodtke appliances are designed only for operation in rooms at normal humidity and at
room temperatures between +5 °C and +25 °C (ambient temperature during operation). At
higher temperatures it can happen that safety devices intervene in the stove’s operation, while
for operation at lower temperatures its settings will need to be adjusted. Please observe the
notes on stove operation concerning this point.
Note: Waterplus appliances require a suitable anti-freeze agent (compatible with solar
energy plants) if they are to be operated at room temperatures <+5°C. wodtke appliances
are generally not splash-proof and must not be installed in wet rooms.
2.6 Connection to chimney
Legal regulations require that pellet stoves be connected to a chimney suitable for solid
fuel fireplaces. The flue gas connector must be made of metal and meet the requirements
of DIN 1298. Your district master chimneysweep will be pleased to advise on this matter. Joint
operation of several appliances via one chimney is admissible, since wodtke stoves fall into
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Wodtke Frank Airplus S4 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Wodtke Frank Airplus S4 in de taal/talen: Engels als bijlage per email.

De handleiding is 3.18 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Wodtke Frank Airplus S4

Wodtke Frank Airplus S4 Gebruiksaanwijzing - Deutsch - 76 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info