813056
57
Verklein
Vergroot
Pagina terug
1/68
Pagina verder
Manual_S5_Airplus_2015_04_20 Page 57 / 68
© Wodtke GmbH - Tübingen. All Rights and Changes Reserved.Printed 04/2015 Part No. 950 976
18.2 Overview of Class 2 Error & Fault Codes (Not Safety-Related)
Class 2 errors are of subordinate importance (not safety-related) and manual reset is not required
after resolving the cause of the fault. The automatically returns to normal operation after resolving
the cause of the fault.
Fault code
Class 2
Cause of fault
Target values
Resolution of fault
L- LO =
Air volume in intake pipe un-
derrun, L-LO indicator blinks in
alternation with the respective
programme indicator.
Measurement point: Air vol-
ume sensor in intake pipe [=
two resistors in bridge circuit,
one resistor continuously
heated. Cooling = function of
flow speed]
External error / operating error! Minimum air
volume in intake pipe underrun longer than
5 seconds.
This occurs due to opening of the combus-
tion chamber doors, for example no air
through-put through the intake pipe
Another cause: if the air through-put through
the unit is no longer possible due to extreme
contamination of the heating gas flues / con-
nector or the resistance in the combustion
line is too high or the combustion air line is
closed/clogged.
L > 2.0
Value is que-
ried continually
starting 1 mi-
nute after start.
After a restart,
the query also
does not hap-
pen until after
1 minute.
There is not a unit defect!
Close combustion chamber
door (if open) or find other
cause (e.g. access panel
open, door not sealed). Per-
form maintenance/cleaning
as required. Unit continues
to operated in the previous
programme after error is re-
solved.
Exception: Flue gas tem-
perature has dropped. Then
the indicator "TR" appears
see Cl. 1 error code
BU Er1 =
BUS error (RS 485 - interface)
BUS error on input "RS 485" with normal
shutdown HE OFF / G OFF / BU ER1. Bus
communication with external heating con-
troller disrupted for longer than 60 seconds
or external heating controller/gateway incor-
rectly connected/defective or RS 485 input
defective.
Error can only occur if the "BUS" input is
switched active (activation / deactivation via
menu level 2 - see Chapter 8.3.3).
Inspect BUS cabling (conti-
nuity, polarity, installation)
to the external gate-
way/controller. Error is reset
automatically + furnace re-
started as soon as the BUS
connection is active again.
Attention: with "BU Er1,"
the furnace can only be
manually operated if the
"BUS" input is deactivated
(activation / deactivation via
menu level 2 - see Chapter
8.3.3).
18.3 Internal Regulation Function "R.M"
This function is summarised here because it partially also serves for technical safety monitoring of the units and is
significantly influenced by external parameters. These are regulation functions - the units respond to external influ-
ences / operating parameters here.
Regulation function / dis-
play indicator
Cause
Target values
Resolution of fault
R.M =
Internal modulation
No error in an actual sense
(regulation function)
Case A: Value for flue gas temperature TR
was exceeded, the unit switches back to
lowest load until the values are met. This is
a regulation function (not a defect), which
can be triggered by operating with pellets
with a high heating value (average output
of the unit is over the rated heating output
as a result).
Case B: The temperature on the air volume
sensor was exceeded. The furnace regu-
lates to the lowest output. Once the tem-
perature lowers sufficiently, the furnace re-
turns to the previously adjusted output.
This is a regulation function (not a defect)
which can be triggered by the combustion
air temperature being too high, for exam-
ple.
TRmax < 999 °C
with hysteresis
6 C
TL< 90 °C
There is an automatic return
from modulation "R.M" to the
preset output as soon as the de-
vice values have lowered by the
cited hysteresis.
57

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Wodtke Crazy.nrg bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Wodtke Crazy.nrg in de taal/talen: Engels als bijlage per email.

De handleiding is 6.01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Wodtke Crazy.nrg

Wodtke Crazy.nrg Gebruiksaanwijzing en installatiehandleiding - Deutsch - 72 pagina's

Wodtke Crazy.nrg Gebruiksaanwijzing - Français - 72 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info