How to Purge Air Tubes
Thermal Insulation Piping:
Place the drain hose under the piping.
Insulating material: polythene foam over 6 mm in thickness.
NOTE: Drain hose is prepared by user.
Drain pipe should point downward for easy drain flow.
Do not twist the drain pipe, leave it sticking out or waving around, and do
not immerse the end in water. If an extension drain hose is connected to
the drain pipe, make sure it is thermally insulated when passing it through
the indoor unit.
When the piping is directed to the right, piping, power cord and drain pipe
should be thermally insulated and fixed at the rear of the unit with a piping
fixer.
1. Insert the pipe fixer into the slot.
2. Press to hook the pipe fixer onto the base.
Piping Connection:
Connect the indoor unit pipes using two wrenches. Pay special attention
to the torque allowed as shown below to prevent the pipes, connectors
and flare nuts from being deformed and damaged.
At first finger-tighten them, then use the wrenches.
For T3 climate kind models, 18 K and 24 K Liquid Side is (ø 6 or ¼ inch) and gas
side is (Ø 16 or 5/8inc).
Model Pipe size Torque
Nut
width
Min.
thickness
7-9-12 K Liquid Side (ø 6 or ¼ inch) 1.8 Kg.m 17 mm 0.6 mm
18,24 K Liquid Side (ø 10 or 3/8 inch) 3.5 Kg.m 22 mm 0.6 mm
7,9 K Gas Side (ø 10 or 3/8 inch) 3.5 Kg.m 22 mm 0.6 mm
12 K Gas Side (ø 12 or ½ inch) 5.5 Kg.m 24 mm 0.6 mm
18,24 K Gas Side (ø 16 or 5/8 inch) 7.5 Kg.m 27 mm 0.6 mm
Base
Piping fixer
Large pipe
Power
connecting cord
Power
connecting
cord 1 (for
heat-pump)
Drain hose
(prepared by user)
Small pipe
Thermally insulated
tube
Base
Piping fixer
Insert here
Large
pipe
Drain
hose
Small
pipe
Hook here
Defrost cable
(for heat-pump)
Unscrew and remove caps from 2 and 3-way valves.
Unscrew and remove cap from service valve.
Connect vacuum pump flexible hose to the service valve.
Start the vacuum pump for 10-15 minutes until it reaches an absolute vacuum of 10 mm Hg.
With the vacuum pump still running close the low pressure knob on the vacuum pump manifold. Then stop the vacuum pump.
Open the 2-way valve ¼ turn, then close it after 10 seconds. Check tightness of all joints using liquid soap or an
electronic leak detector.
Turn the 2 and 3-way valves stem. Disconnect the vacuum pump flexible hose.
Replace and tighten all valve caps.
NOTES:
Please read this manual before installing and using the appliance.
Do not let air enter the refrigerating system or discharge refrigerant when moving the air conditioner.
Test run the air conditioner after finishing installation, and record details of operation.
Type of fuse used on indoor unit control is 50 T, with rating 2.5 A,T,250 V.
The fuse for the whole unit is to be provided by the user according to the current at maximum power input or use
another over-current protective device instead.
The power connection for the air conditioner has to be made at the main power distribution which has to be of a low
impedance. In order to ensure the suitability of the equipment for connection, the user should consult the supply authority, if
necessary, to check that the service current capacity at the interface point is sufficient for the equipment. Refer to the rating
plate of the equipment for power consumption details. If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or similarly qualified person in order to avoid a hazard. When charging refrigerant into the system, make
sure to charge in liquid state, if the refrigerant of the appliance is R407C or R410a. Otherwise, the chemical composition of
the refrigerant inside the system may change and thus affect performance of the air conditioner. According to the character
of refrigerant (R410a), the pressure of the tube is very high, so ben sure to be careful when you install and repair the appliance.
Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect it if necessary.
If this is not possible, connect the appliance to a double-pole switching device with contact distance of at least 3 mm
placed in a position accessible even after installation.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Whirlpool AMD 002 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Whirlpool AMD 002 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Whirlpool AMD 002

Whirlpool AMD 002 Gebruiksaanwijzing - Nederlands - 18 pagina's

Whirlpool AMD 002 Gebruiksaanwijzing - Deutsch - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info