Filling the boiler | 5
9026381C Dual Top ST 6 _ 8 - OI 15 / 19
NOTE
Draining the boiler as well as the frost protection mode
protect the heater and boiler against frost. Not all wa-
ter lines in the vehicle can be protected against freezing
due to installation variations.
When storing the vehicle, either choose a place that is
well protected against low temperatures or drain the
whole water system, including all lines and tubes (e.g.
with air pressure, see note in chapter4.7.1, "Draining
the boiler manually" on page 14 ).
Warranty claims for damage caused by frost will not
be honoured!
4.7.4 Frost protection
The frost protection mode is a safety feature for the heater only.
It does not prevent the water circuits inside and outside the
vehicle from freezing.
Store the vehicle at a place that is well protected against frost
or drain water contents if there is a risk of frost!
For Dual Top ST with a manual control panel: To avoid freezing
of the tubes and the boiler move mode selector knob (A) to
frost protection mode (5).
The indicator (C) on the control panel lights green when the
equipment is switched on. The red indicator on the mode se-
lector knob (A) illuminates.
The heater functions as in the wintermode, heating with hot
water production, but with lower values for air and water tem-
peratures.
For Dual Top ST with a programmable control panel: Make sure
the device is switched on.
1. Press MENU.
2. Press and to select “Frost Protection”.
3. Press OK. For Dual Top ST 6: The display shows: “Selection
completed“.
4. For Dual Top ST 8: Press and to select the desired
heat source:
Dual Top ST 8
“Diesel powered”
“1,000 W ~ 230 V” *
“2,000 W ~ 230 V” *
* Options “...W ~ 230 V” shown only when external 230 V
power supply is connected.
5. Press OK. The display shows: “Selection completed”.
NOTE
When the heater is already “ON”, the text “Selection
completed, press OK to change operation mode” is
displayed.
uPress OK.
After 3 seconds the power indicator (6) lights up in green and
the display changes to:
11000W
230V und … W: Only Dual Top ST 8
“Heater ON”
Frost Protection Boiler
diesel“, “ 1000 W“ or “ 2000 W” (depending
on heater type and selected heat source).
The heater functions as in the winter mode, heating with hot
water production, but with lower values for air and water tem-
peratures.
NOTE
When the frost protection mode is selected in depend-
ence on the selected heat source, diesel and electrical
power are used. Therefore, it should be ensured that
the battery is charged and there is enough diesel in the
tank when "Diesel mode" is selected. Check this fre-
quently.
NOTE
When ambient temperatures below -20 °C are expec-
ted, select heat source “Diesel powered” for 100%
frost protection of the system.
NOTE
Make sure that the boiler is filled with water when
choosing frost protection mode.
NOTE
The frost protection mode enables the user to park the
vehicle for a short time without being observed and
without having to worry about frost and frost damage.
During winter storage or when parking the unused
vehicle for a longer time, the entire water system
should be drained and the heater disconnected from
the battery to avoid unnecessary battery discharging or
possible frost damage.
5 Filling the boiler
Fill the vehicle fresh drinking water tank with your own hose,
which is kept and stored clean.
Before filling the tank rinse the hose thoroughly (approx. 30
seconds).
CAUTION
Always fill the tank with fresh drinking water only and
prevent dirt from getting into the entire water supply
system.
1. Fill the boiler with fresh drinking water at an ambient tem-
perature of at least 6 °C, or select:
- summer mode 40°C or 70°C, see chapter4.2.1, "Summer
mode (hot water only)" on page 7 or chapter4.3.6, "Sum-
mer mode (hot water only)" on page 9",
- winter mode (heating with hot water production), see
chapter4.3.8, "Winter mode (heating with hot water pro-
duction)" on page 10" or chapter4.2.3, "Winter mode
(heating with hot water production)" on page 7, to make
sure the electrical safety/drainage valve does not open!
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Webasto Dual Top ST 6 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Webasto Dual Top ST 6 in de taal/talen: Engels als bijlage per email.

De handleiding is 6.42 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Webasto Dual Top ST 6

Webasto Dual Top ST 6 Gebruiksaanwijzing - Nederlands - 21 pagina's

Webasto Dual Top ST 6 Gebruiksaanwijzing - Deutsch - 21 pagina's

Webasto Dual Top ST 6 Gebruiksaanwijzing - Français - 21 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info