668530
8
Verklein
Vergroot
Pagina terug
1/18
Pagina verder
PPL IMP 1234A
PROGRAM menu :
By pressing & keys the Program number starts to blink,
and use
& to see the
Then use
& to other days in the program
Select the program
Shows the daily program
If you select a built-in program “P1 to P9” and press this program will be followed in
Built-in programs description
P1 Morning, Evening & Week-end P6 Morning, Afternoon & Week-end
P2 Morning, Midi, Evening & Week-end P7 7h - 19h (Office)
P3 Day & Week-end P8 8h - 19h , Saturday (Shop)
P4 Evening & Week-end P9 Week-end (Secondary House)
P5 Morning, Evening (bathroom)
If you select a built-in program ”U1 to U4” and press you will enter in user program edition.
USER PROGRAM EDITION day
Hour at the cursor position
The key sets temperature at the current blinking program hour
The
key sets temperature at the current blinking program hour
Use & keys to slide the blinking cursor position in the day and modify or correct easily the
program. When the displayed day is correct press to jump to the following day.
When you press
on day 7 you return to the top menu
Now your user program will be followed if you put the MILUX RF in
operating mode.
Set CLOCK Menu :
Use this menu to adjust the clock .
Use & to
ajust the minutes.
Press key
Use &
Adjust the hours.
Press key
Use &
Adjust the day
Press key
COMFORT operating mode :
By pressing & keys the comfort
temperature starts to blink and can be adjusted.
The room temperature
reappears after a few
seconds
The MILUX RF regulation will now follow
indefinitely the comfort temperature.
AUTOMATIC operating mode:
MILUX RF will follow automatically the program
according to the actual time
By pressing & key you can override the
current set temperature until the next change in
the program.
The segment will lit up. Use & keys
to adjust the temporary required temperature.
At the next program change the will
disappear and the program continues without any
alteration.
RADIO CONFIGURATION WITH THE RECEIVER
1. To assign the MILUX RF thermostat with the receiver you must put the receiver in “RF init
mode, please refer to the receiver leaflet.
(In this mode the thermostat should be near the
receiver)
2. On the MILUX RF, select
operating mode.
Then press the key during 5 seconds,
you will enter in the Radio configuration mode (
).
The MILUX RF is now sending by radio signal its configuration address 4 times per second,
3. You can now perform a radio range verification.
Place the MILUX RF in the room where you need to regulate the temperature and leave it in
Radio configuration mode ( ).
Close the doors and come back to the Receiver.
Verify that the green LED blinks at each radio signal received :
- If it blinks regularly 4 times per second, the installation of the MILUX RF and Receiver is
correct.
- If it blinks irregularly, you are at the range limit. Install the MILUX RF closer to the Receiver.
- If it does not blink at all, you are out of range. Install the MILUX RF closer to the Receiver.
4. On the MILUX RF press on the key to exit the Radio configuration mode.
Now your MILUX RF controls the Receiver.
Wireless communication by radio signal to
the receiver connected to the
installation.
Range of approximately 30m in
residential environment.
7 day program
9 Built-in programs and 4 User programs
Program graphic display
Room temperature and time display
Comfort / Reduced / Anti-freeze
temperatures
Temporary temperature override
Automatic or Manual operation
Holiday function
Keypad lock function (child safety)
Battery operated, life >2 years
Battery weakness display
Battery replacement without loss of
the program memory (<1minute)
Reset function
ITCS function (optional). Intelligent
Temperature Control System.
1: Heater in operation
2: Temperature overridden
3: Holiday function activated
4: Operating mode menu
5: Batteries weak
6: Day of the week
7: Time
8: Current day graphic program display
and radio transmission activity
9: If lit-up 10 display the current room temperature
10: Room tem
p
erature or set tem
p
erature
REDUCED operating mode :
By pressing & keys the comfort
temperature starts to blink and can be
adjusted.
The room temperature
reappears after
a few seconds
The MILUX RF regulation will now follow
indefinitely the reduced temperature.
ANTI FREEZE operating mode:
Prevent your installation from freezing.
By pressing
& keys the anti freeze
temperature starts to blink and can be
adjusted.
The room temperature
reappears after a
few seconds
Now the MILUX RF will keep the
temperature above freezing.
OFF mode :
Use this mode if your Heating installation
needs to be turned OFF.
The MILUX RF will switch off the
installation and then switch itself OFF
(blank screen).
User programs are saved, time is kept
running and battery consumption becomes
very low.
Any key will wake up the MILUX RF.
The key display the actual room
temperature.
DANGER: has your thermostat is
stopped YOUR INSTALLATION CAN
FREEZE.
HOLIDAY Function :
With & keys, go to function. Then select with & keys the delay in hours
( H ) if below 24h then in days ( d ). Then select a mode or or .
The logo is active and the number of hours/days left is displayed until the MILUX RF
returns in mode and continues to follow the program.
KEYPAD LOCK Function :
Function to prevent any modification of the parameters.
In , , , and operating modes you can maintain the key pressed and
press simultaneously on the or key to lock ( ) or unlock ( ) the
keypad.
RESET Function :
Erase all user programs and sets the factory parameters by default.
Go to mode, maintain & keys pressed and press simultaneously on the key.
All segments will lit up during a few seconds showing that the MILUX RF has been erased and
restarted with factory defaults parameters.
Factory parameters are :
Temperatures 21°C 17°C 6°C, Program U1 all comfort.
CHARACTERISTICS
MODES DESCRIPTION
DISPLA
Y
SPECIAL FUNCTIONS
USER GUIDE
GB
Use & keys to change the mode in the Operating mode menu
For all operating modes the receiver switch should be placed on AUTO position.
C
hr
o
n
o
-Th
e
rm
ostat
MIL
U
X RF
TECHNICAL CHARACTERISTICS
Operating temperature 0°C - 50°C (o 32°F – 122°F)
Measured temperature precision 0.1°C (or 0.2°F)
Set temperature precision 0.5°C (or 0.5°F)
Set temperature range
in comfort & reduced : 5°C – 35°C (or 41 - 95°F)
in anti-freeze: 0,5°C – 10°C (or 33 – 50°F)
Regulation
characteristics
Cycle: 15 minutes
Anti-short cycle: 3 minutes OFF, 2 minutes ON
Electrical Protection Class II - IP30
Batteries
3x LR6 AA 1.5V alkaline batteries (> 2 years)
IMPORTANT: You have 1 minute to change the
batteries.Past this time, you may have to reprogram
your thermostat if all segments lit up at power up.
Radio Frequency 433.92 MHz, <10mW.
Certifications
CE. EN 300220-3, EN 301489-1
(Radio frequency certifications)
8
4
5
6
7
3
2
1
10
9
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Watts WFHTRF 01 -20033 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Watts WFHTRF 01 -20033 in de taal/talen: Engels, Spaans als bijlage per email.

De handleiding is 4,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info