PPLIMP2350Bb page 30
GB
6. TYPES OF OPERATING MODES / PROGRAM MENU
6.3 TYPES OF OPERATING MODES
Selection of the operating mode is done using the arrow keys (◄) and (►). The cursor must be positioned on the
symbol of the relevant operating mode.
NORMAL mode of operation
Unlimited operation in NORMAL mode .
The system runs in constant heating mode. The Heating Controller adjusts the flow temperature depending
on the outdoor temperature and the selected heating curve. No temperature setback.
The display Pos. 5 shows the current flow temperature and the outside temperature at 13 (damped value).
By pressing the button (OK) the preset value of flow temperature appears for about 3 seconds at 5. At the
same time the manually selectable deviation is displayed at 13 (factory setup: 00.0 = no deviation). Using
the buttons (+) or (-) you can adjust the preset value of the flow temperature. If changed, the symbol
appears on the display.
In heating mode of operation the circulation pump is running continuously. The pump switches off if the
preset value of the flow temperature is exceeded for 30 minutes. That is the case when the room heating is
sufficient and the room thermostat closes all heating circuits by means of actuators. The same happens
when the value of flow temperature calculated by the Controller becomes lower than the actual tempera-
ture value because of rising outdoor temperatures. If the actual value of the flow temperature falls below
the preset value, the pump starts.
To ensure energy saving operating mode of the pump it could be switched by a “pump logic” of a elec-
tric connecting box. The connecting box is normally used together with room thermostats and electrother-
mic actuators. The “pump logic” is a potential free switching relay, the contact of which is closed whenever
higher temperature is demanded in any of the rooms. If all rooms are warm enough, the contact opens and
the pump turns off.
If the heat generator / boiler (WE) is in temperature setback and the temperature supplied by the WE is
below the preset temperature calculated by the Controller, heating mode is not available. However if the
circulation pump is actually running and the 2/3-way valve may also be opened by the 3-point actuator
because of room heating demand, the preset value of flow temperature may be exceeded for a short pe-
riod of time when the WE switches to heating mode. In this case, if a temperature limiter is available, the
pump might switch off and then pump operation will be possible only after the temperature drops below the
preset maximum temperature of the TB.
Trouble-shooting: The TB should be installed at a greater distance from the control unit. If necessary you
can set the TB to a higher temperature until the pump starts. After a few minutes of pump operation the
maximum allowable temperature set on the TB should be restored. Alternatively you can remove the TB
from the pipe for a while and leave the pump running for a few minutes. Then refit the TB again to the pipe.
AUTOMATIC mode of operation
Automatic mode of operation using the built-in or user programs.
The heating system is controlled according to the selected built-in or user program ( 6.2.).
If the system is in heating mode, the flow temperature is controlled depending on the outdoor temperature
and the heating curve.
For the operation of the circulation pump please refer to the section of NORMAL mode of operation.
REDUCED TEMPERATURE mode of operation
Unlimited operation in REDUCED TEMPERATURE mode .
This is a constant mode of operation of the system. The heating Controller adjusts the flow temperature
continuously on the basis of outdoor temperature and the selected heating curve and deducting the value
of temperature setback (factory setting -10.0 К).
The display indicates the current flow temperature at 5 and the outside temperature at 13. By pressing the
button (OK) the preset value for the supply flow temperature reduced by the setback in temperature is
displayed at 5 for 3 seconds. Simultaneously the reducing difference appears in 13 (without deviation =
-10.0). It can be changed by the buttons (+) or (-).
For the operation of the circulation pump please refer to the section of NORMAL mode of operation.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Watts Climatic Control H bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Watts Climatic Control H in de taal/talen: Engels als bijlage per email.

De handleiding is 1.09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info