Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: Info@Aktobis.de
Mould remediation
Between 240 and 800 minutes
Disinfection:
Between 60 and 240 minutes
Automotive treatment:
Between 90 and 180 minutes
3. After the end of the treatment period
Do not enter the treatment room/object until at least 30 minutes after the end of the ozone generation phase.
Immediately check whether the unit is also no longer producing ozone, switch it off completely and disconnect the
mains plug.
Ensure that the room/object is sufficiently ventilated with fresh air from outside. In this context, we recommend that
you ventilate the room for approx. 20 minutes before people or animals enter the room again!
If the ozone-treated room cannot be ventilated with fresh air from outside (e.g. due to its construction) and the
ozone treatment phase lasted longer than 80 minutes, we do not recommend that humans and animals stay in this
room for approx. 60 minutes. In case of an ozone treatment phase longer than 400 minutes, we recommend no
stay of humans and animals in this room for the duration of approx. 2 hours.
4. Cleaning
Only clean the housing !
Please disconnect the mains plug before cleaning the ozone generator.
Only use mild cleaning agents to clean your ozone generator.
NEVER hose down your ozone generator (e.g. with water or similar).
Technical data
Model designation: WDH-AP001
Voltage: 220-240V ~ 50Hz
Maximum power consumption: 110 W (0.5 A)
Ozone output (optimal): 1,000 mg/h (1 g/h)
Max. Ozone concentration: 15-25 mg/l
Waterproofness: IPx0
Dimension (H/W/D): 280 x 145 x 260 mm
Weight: 3,2 kg
Application range: 5°C - 40°C / max. 75 % r. humidity