580333
34
Verklein
Vergroot
Pagina terug
1/36
Pagina verder
34 D-302989
function. Instead the PowerMaxExpress dials telephone
numbers and reports the event to central stations and/or
to private telephones, as programmed.
24 Hour Zone - Audible. - Upon detection, this zone
initiates a siren alarm. The PowerMaxExpress also dials
telephone numbers and reports the event to central
stations and/or to private telephones, as programmed.
C14. Key Zones (Optional)
Key zones are zones that can be used for arming and
disarming the system by MCT-100 and MCT-102
PowerCode transmitters that are enrolled to a zone. In
addition, the alarm system may be armed / disarmed by a
keyswitch when connected to wired zone 29.
Defining a zone as a KEY ZONE includes the following actions:
a. The zone should be defined as non-alarm type zone
(see par. 4.3).
b. "Z-KEY ENABLE" should be selected for such a zone
(see par. 4.3).
c. According to the zone number, "z. 21-28 enable", "z.29
enable", or "z. 21-29 enable" should be selected in the
DEFINE PANEL menu (see par. 4.4.39).
APPENDIX D. PowerMaxExpress Compatible Devices
D1. PowerMaxExpress Compatible
Detectors
Each detector compatible with the PowerMaxExpress
system is packed with its own installation instructions.
Read them carefully and install as indicated.
A. PIR Motion Detectors
The wireless passive infrared (PIR) motion detectors used
in the system are of the PowerCode type. The
PowerMaxExpress is capable of “learning” each detector’s
identification code and linking it to a specific zone (see par.
4.3 in this Guide). Some units are shown below:
NEXT
®
K9-85 MCW
MCPIR-3000
or K-940 MCW
DISCOVERY
K9-80/MCW
Note: K-940 MCW, Discovery K9-80/MCW and NEXT
®
K9-85 MCW are pet immune units.
In addition to its unique 24-bit identification code, each
detector transmits a message, containing status
information:
The detector is in alarm (or not).
The detector is being tampered with (or not).
The battery voltage is low (or normal).
“This is a supervisory message”.
If any of these detectors detects motion, it sends out a
message to the alarm control panel. If the system is in the
armed state, an alarm will be triggered.
B. Magnetic Contact Transmitter
MCT-302 is a PowerCode magnetic-
contact transmitter used to detect the
opening of a door or a window.
The alarm
contacts are closed as
long as the door or
window remains
closed.
MCT-302
The unit has an extra alarm input that acts as if it were a
separate wireless transmitter. It sends (or does not send) a
“restored to normal“ message to the alarm system,
depending on the setting of an on-board “DIP” switch. The
“restore” message informs you, through the control panel’s
display, whether the door or window is open or closed.
C. MCT-100 Wireless Adapter for Wired Detectors
MCT-100 is a PowerCode device used
mainly as a wireless adapter for 2 regular
magnetic switches installed on 2 windows in
the same room. It has two inputs, behaving
as separate wireless transmitters with
different PowerCode IDs. Each input sends
(or does not send) a “restored“ message to
the alarm system, depending on the setting
of an on-board “DIP” switch.
MCT-100
D. Wireless Smoke Detector
MCT-425. A photoelectric smoke
detector equipped with a
PowerCode-type transmitter. If
enrolled to a fire zone, it initiates a
fire alarm upon detection of smoke.
MCT-425
E. Glass Break Detector
MCT-501 An acoustic detector
equipped with a PowerCode-type
transmitter. Since it restores
automatically after detection, this unit
does not send a restoral message to
the control panel.
MCT-501
D2. PowerMaxExpress Compatible
Transmitters
The PowerMaxExpress system is compatible with multi-
button and single button key-ring and hand-held
transmitters that use PowerCode and CodeSecure coding
methods.
Multi-button PowerCode transmitters transmit the same
code each time the same button is pressed. They can be
used for emergency signaling. They can not be used for
arming / disarming.
CodeSecure transmitters are of the rolling code type - they
transmit a new code each time the same button is pressed.
This provides a higher security level, especially in arming /
disarming applications, because the code can not be
copied (“grabbed”) by unauthorized people.
Following are the basic details of several compatible
transmitters. The possible applications for each push-
button are indicated in each drawing.
A. MCT-234
‘Keyfob’ transmitter. You
can program the AUX
(auxiliary) button to perform
various tasks, in
accordance with the user’s
needs.
Pressing AWAY and
HOME together for 2 sec.
initiates PANIC alarm.
Pressing AWAY for 2 sec.
initiates Latchkey arming.
DISARM
AWAY
AUX
HOME
MCT-234
B. MCT-231 / 201*
(N.A. in North America)
Single-button pendant units.
The MCT-231 (Code- Secure)
and the MCT-201
(PowerCode) can be enrolled
to perform functions as shown.
Both units look alike.
MCT-231 / 201
34

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Visonic PowerMax Express bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Visonic PowerMax Express in de taal/talen: Engels als bijlage per email.

De handleiding is 3,94 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Visonic PowerMax Express

Visonic PowerMax Express Gebruiksaanwijzing - Nederlands - 35 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info