558346
8
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
Operating instructions
for the system user
VIESMANN
Control unit for solar thermal systems
VITOSOLIC 100
5592640 GB 10/2023 Please keep safe.
2
Please follow these safety instructions closely to
prevent accidents and material losses.
Safety instructions explained
Danger
This symbol warns against the risk of injury.
!Please note
This symbol warns against the risk of material
losses and environmental pollution.
Note
Details identified by the word "Note" contain additional
information.
Target group
These operating instructions are intended for system
users.
This appliance can also be operated by children of 8
years and older, as well as by individuals with reduced
physical, sensory or mental faculties or those lacking
in experience and knowledge, provided such individu-
als are being supervised or have been instructed in the
safe use of this appliance as well as in any risks aris-
ing from it.
!Please note
Supervise children in the proximity of the appli-
ance.
Never permit children to play with the appli-
ance.
Cleaning and maintenance must not be car-
ried out by unsupervised children.
Appliance connection
The appliance may only be connected and commis-
sioned by authorised contractors.
Observe the specified electrical connection require-
ments.
Modifications to the existing installation may only be
carried out by authorised contractors.
Danger
Incorrectly executed work on the system can
lead to life-threatening accidents.
Work on electrical equipment must only be car-
ried out by a qualified electrician.
Work on the appliance
All settings and work on the appliance must be car-
ried out as specified in these operating instructions.
Further work on the appliance may only be carried
out by authorised contractors.
Never open the appliance.
Never change or remove fitted accessories.
In case of fire
Danger
Fire presents a risk of burns and explosion.
Switch the system OFF.
Use a tested fire extinguisher, class ABC.
Auxiliary components, spare and wearing parts
!Please note
Components that were not tested with the sys-
tem may cause system damage, or may affect
its functions.
Have all installation or replacement work carried
out by qualified contractors.
Safety instructions
For your safety
5592640
3
The commissioning and adjusting of the control unit to
local conditions and to building characteristics, plus the
instruction of the user in operating the system, must be
carried out by your heating contractor.
Introductory information
Commissioning
5592640
4
Controls
KOL
°C
AB
Fig. 1
AOK to confirm your selection or setting.
BSymbols line
To terminate a value adjustment in progress.
/ Cursor keys
To scroll through the menu.
/ Cursor keys
To adjust values.
To change from the scanning level to the setting
level
To the right, underneath the symbol line on the display,
you will see which keys you can operate to make
adjustments and scans.
Symbols on the display
These symbols are not always displayed, but appear
subject to the system operating condition.
Symbol Permanent display Flashing
The system is operational.
ÂRelay 1 is on.
The solar circuit pump is running.
ÃRelay 2 is on.
ÈThe set DHW temperature has been
reached.
Collector cooling function, return cooling
function enabled
ÇThe frost protection function is enabled. Failed to reach minimum collector tem-
perature
¨Emergency collector shutdown (collector
limit temperature reached) or cylinder
emergency stop active
¨+ÄSensor fault:
Ä ¨
¨+ÆManual mode:
Æ ¨
SET You can change the relevant parame-
ters.
Change parameters with / .
Operation
Operation
5592640
5
Use / to scan the following actual values subject to
the system equipment level:
Note
The flashing sensor symbol in the system scheme
shows the position of the actual temperature.
KOL Collector temperature in °C (standard display)
TSPU DHW temperature in °C
S3 Thermostat temperature in °C,
temperature at any additional connected sensor that
may be connected
n1% Solar circuit pump speed
n2% Operating condition of the actuator at relay
output R2
hP1 Hours run of the equipment at relay output 1
hP2 Hours run of the equipment at relay output 2
KWh Amount of heat in kWh, if the heat meter is
enabled
MWh Amount of heat in MWh, if the heat meter is
enabled
Note
Add the values for MWh and kWh together.
Resetting hours run and amount of heat
Whilst the value is displayed, press the following keys:
1. OK "SET" flashes. Value 0 appears.
2. OK to confirm
Scanning options
Displaying actual values
5592640
6
Cause Remedy
The solar control unit MCB has responded. Inform your local heating contractor.
Power failure The solar control unit automatically returns to operation
once the power supply has been restored.
The power distribution MCB (main domestic MCB) has
responded.
Check the MCB and inform your heating contractor if
necessary.
The collector limit temperature or maximum cylinder
temperature has been reached.
Wait until the relevant temperature has fallen below its
respective limit.
The solar control unit is in manual mode.
The display shows "Æ" and "¨" flashes.
Select "Auto":
1. Press until "ANL" is displayed.
2. Press until "HND 1" or "HND 2" is displayed.
3. Press OK, "SET" flashes.
4. Press until "Auto" is displayed.
5. Press OK to confirm.
6. Press . The collector temperature is displayed.
There is no DHW available
Cause Remedy
The solar control unit is faulty. Inform your local heating contractor.
The collector temperature is too high, safety shutdown
by the solar control unit.
Wait until the collector temperature has dropped.
The set cylinder temperature (set DHW temperature) is
set too low.
Inform your local heating contractor.
The solar circuit pump is faulty. Inform your local heating contractor.
The DHW cylinder is not being reheated:
The operating and time programs on the boiler control
unit are incorrectly set.
Enable DHW heating.
Operating instructions of the boiler control unit
The display is flashing
Cause Remedy
Example, sensor fault
KOL
°C
The sensor symbol in the system scheme flashes
quickly.
¨ flashes.
Read off the fault code. Inform your local heating con-
tractor.
In the example, the collector temperature sensor has a
short circuit.
88.8 Sensor short circuit
888.8 Sensor lead break
Note
Check other sensors with / .
What to do if...
The solar thermal system does not start
5592640
7
DHW cylinder (if installed)
Standards DIN 1988-8 and EN 806 specify that main-
tenance and cleaning should be carried out no later
than 2 years after commissioning and as required
thereafter.
Only a qualified heating contractor should clean the
inside of a DHW cylinder and the DHW connections.
If any water treatment equipment (e.g. a sluice or
injection system) is installed in the cold water supply of
the DHW cylinder, ensure this is refilled in good time.
In this connection, observe the manufacturer's instruc-
tions.
In addition for Vitocell 100:
We recommend that the correct function of the sacrifi-
cial anode is checked annually by your heating con-
tractor.
The function of the sacrificial anode can be checked
without interrupting the system operation. The heating
contractor will check the earth current with an anode
tester.
Safety valve (DHW cylinder)
The function of the safety valve must be checked
every six months by the user or a contractor through
venting (see valve manufacturer's instructions). The
valve seat may become contaminated.
Water may drip from the safety valve during a heat-up
process. The outlet is open to the atmosphere and
must not be closed off.
Potable water filter (if installed)
To maintain high hygienic standards, proceed as fol-
lows:
Replace filter element on non-back flushing filters
every six months (visual inspection every
two months).
On back flushing filters, back flush every
two months.
Damaged cables / lines
If there is damage to the connecting cables or lines of
the appliance or externally installed accessories, these
must be replaced with special cables or lines. Only use
Viessmann cables / lines as replacement. For this,
notify your qualified contractor.
Upkeep
Inspection and maintenance
5592640
8
Your contact
Contact your local contractor if you have any questions about your system or wish to arrange maintenance or
repair work. You can find local contractors on the internet at www.viessmann.de.
Viessmann Limited
Hortonwood 30, Telford
Shropshire, TF1 7YP, GB
Telephone: +44 1952 675000
Fax: +44 1952 675040
E-mail: info-uk@viessmann.com
Viessmann Climate Solutions SE
35108 Allendorf / Germany
Telephone: +49 6452 70-0
Fax: +49 6452 70-2780
www.viessmann.com
Your contact
Contact your local contractor if you have any questions about your system or wish to arrange maintenance or
repair work. You can find local contractors on the internet at www.viessmann.de.
Viessmann Limited
Hortonwood 30, Telford
Shropshire, TF1 7YP, GB
Telephone: +44 1952 675000
Fax: +44 1952 675040
E-mail: info-uk@viessmann.com
Viessmann Climate Solutions SE
35108 Allendorf / Germany
Telephone: +49 6452 70-0
Fax: +49 6452 70-2780
www.viessmann.com
5592640 Subject to technical modifications.
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Viessmann VITOSOLIC 100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Viessmann VITOSOLIC 100 in de taal/talen: Engels als bijlage per email.

De handleiding is 0.34 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Viessmann VITOSOLIC 100

Viessmann VITOSOLIC 100 Installatiehandleiding - Nederlands - 72 pagina's

Viessmann VITOSOLIC 100 Gebruiksaanwijzing - Nederlands - 8 pagina's

Viessmann VITOSOLIC 100 Gebruiksaanwijzing - Deutsch - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info