7. ERROR INDICATIONS
With the procedures below, most errors can be quickly identified. If an error cannot be resolved, please refer to your Victron
Energy supplier.
7.1 General error indications
Problem
Cause
Solution
Quattro will not switch over to
generator or mains operation.
Circuit breaker or fuse in the
AC-in input is open as a result of overload.
Remove overload or short circuit on AC-out-1 or AC-out-2, and
reset fuse/breaker.
Inverter operation not initiated
when switched on.
The battery voltage is excessively high or too
low. No voltage on DC connection.
Ensure that the battery voltage is within the correct range.
“Low battery” LED flashes.
The battery voltage is low.
Charge the battery or check the battery connections.
“Low battery” LED lights.
The converter switches off because the battery
voltage is too low.
Charge the battery or check the battery connections.
“Overload” LED flashes.
The converter load is higher than the nominal
load.
Reduce the load.
“Overload” LED lights.
The converter is switched off due to
excessively high load.
Reduce the load.
“Temperature” LED flashes or
lights.
The environmental temperature is high, or the
load is too high.
Install the converter in cool and well-ventilated environment, or
reduce the load.
“Low battery” and “overload”
LEDs flash intermittently.
Low battery voltage and excessively high load.
Charge the batteries, disconnect or reduce the load, or install
higher capacity batteries. Fit shorter and/or thicker battery cables.
“Low battery” and “overload”
LEDs flash simultaneously.
Ripple voltage on the DC connection exceeds
1,5Vrms.
Check the battery cables and battery connections. Check whether
battery capacity is sufficiently high, and increase this if necessary.
“Low battery” and “overload
LEDs light.
The inverter is switched off due to an
excessively high ripple voltage on the input.
Install batteries with a larger capacity. Fit shorter and/or thicker
battery cables, and reset the inverter (switch off, and then on
again).
One alarm LED lights and the
second flashes.
The inverter is switched off due to alarm
activation by the lighted LED. The flashing
LED indicates that the inverter was about to
switch off due to the related alarm.
Check this table for appropriate measures in regard to this alarm
state.
The charger does not operate.
The AC input voltage or frequency is not within
the range set.
Ensure that the AC input is between 185 VAC and 265 VAC, and that
the frequency is within the range set (default setting 45-65Hz).
Circuit breaker or fuse in the
AC-in input is open as a result of overload.
Remove overload or short circuit on AC-out-1 or AC-out-2, and reset
fuse/breaker.
The battery fuse has blown.
Replace the battery fuse.
The distortion or the AC input voltage is too large
(generally generator supply).
Turn the settings WeakAC and dynamic current limiter on.
The charger does not operate.
“Bulk” LED flashes and “Mains on” LED
illuminates.
MultiPlus is in “Bulk protection” mode thus, the
maximum bulk charging time of 10 hours is exceeded.
Such a long charging time could indicate a system
error (e.g. a battery cell short-circuit).
Check your batteries.
NOTE: You can reset the error mode by switching off and back on the
MultiPlus.
The standard Quattro factory setting of the “Bulk protection” mode is
switched on. The “Bulk protection” mode can be switched off with help of
VEConfigure only.
The battery is not completely
charged.
Charging current excessively high, causing
premature absorption phase.
Set the charging current to a level between 0.1 and 0.2 times the
battery capacity.
Poor battery connection.
Check the battery connections.
The absorption voltage has been set to an
incorrect level (too low).
Set the absorption voltage to the correct level.
The float voltage has been set to an incorrect
level (too low).
Set the float voltage to the correct level.
The available charging time is too short to fully
charge the battery.
Select a longer charging time or higher charging current.
The absorption time is too short. For adaptive
charging this can be caused by an extremely
high charging current with respect to battery
capacity, so that bulk time is insufficient.
Reduce the charging current or select the ‘fixed’ charging
characteristics.
The battery is overcharged.
The absorption voltage is set to an incorrect
level (too high).
Set the absorption voltage to the correct level.
The float voltage is set to an incorrect level (too
high).
Set the float voltage to the correct level.
Poor battery condition.
Replace the battery.
The battery temperature is too high (due to poor
ventilation, excessively high environmental
temperature, or excessively high charging
current).
Improve ventilation, install batteries in a cooler environment, reduce
the charging current, and connect the temperature sensor.
The charging current drops to 0
as soon as the absorption phase
initiates.
The battery is over-heated (>50°C)
Install the battery in a cooler environment
Reduce the charging current
Check whether one of the battery cells has an internal short circuit
Defective battery temperature sensor
Disconnect the temperature sensor plug in the Quattro. If charging
functions correctly after approximately 1 minute, the temperature
sensor should be replaced.
22

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Victron Quattro 48 15000 200-100 100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Victron Quattro 48 15000 200-100 100 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Zweeds als bijlage per email.

De handleiding is 2.72 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info