10. Maintenance
The product does not require specific maintenance. It will suffice to check all connections once a year. Avoid moisture
and oil/soot/vapours, and keep the device clean.
11. Error Indications
With the procedures below, most errors can be quickly identified. If an error cannot be resolved, please refer to your
Victron Energy supplier.
11.1 General error indications
Problem
Cause
Solution
No output voltage on AC-out-2.
EasySolar-II GX in inverter mode
Unit will not switch over to generator or
mains operation.
Circuit breaker or fuse in the AC-in input
is open as a result of overload.
Remove overload or short circuit on AC-
out-1 or AC-out-2, and reset fuse/breaker.
Inverter operation not initiated when
switched on.
The battery voltage is excessively high or
too low. No voltage on DC connection.
Ensure that the battery voltage is within
the correct range.
'Low battery' The battery voltage is low.
Charge the battery or check the battery
connections.
'Low battery' (Shutdown)
The converter switches off because the
battery voltage is too low.
Charge the battery or check the battery
connections.
'Overload'
The converter load is higher than the
nominal load.
Reduce the load.
'Overload' (Shutdown)
The converter is switched off due to
excessively high load. Reduce the load.
'Over Temperature' The environmental temperature is high,
or the load is too high.
Install the converter in cool and well-
ventilated environment, or reduce the
load.
'Low Bat V Overload' (Shutdown) Low battery voltage and excessively high
load.
Charge the batteries, disconnect or
reduce the load, or install higher capacity
batteries. Fit shorter and/or thicker
battery cables.
'High DC Ripple' Ripple voltage on the DC connection
exceeds 1,5Vrms.
Check the battery cables and battery
connections. Check whether battery
capacity is sufficiently high, and increase
this if necessary.
'DC Ripple Shutdown'
The inverter is switched off due to an
excessively high ripple voltage on the
input.
Install batteries with a larger capacity. Fit
shorter and/or thicker battery cables, and
reset the inverter (switch off, and then on
again).
The charger does not operate. The AC input voltage or frequency is not
within the range set.
Ensure that the AC input is between
185VAC and 265VAC, and that the
frequency is within the range set (default
setting 45-65 Hz).
Circuit breaker or fuse in the AC-in input
is open as a result of overload.
Remove overload or short circuit on AC-
out-1 or AC-out-2, and reset fuse/breaker.
The battery fuse has blown.
Replace the battery fuse.
The distortion or the AC input voltage is
too large (generally generator supply).
Turn the settings WeakAC and dynamic
current limiter on.
The charger does not operate. 'Bulk
Protection' shown.
EasySolar-II GX is in 'Bulk protection'
mode thus, the maximum bulk charging
time of 10 hours is exceeded. Such a long
charging time could indicate a system
error (e.g. a battery cell short-circuit).
Check your batteries. NOTE: You can reset
the error mode by switching off and back
on the EasySolar-II GX. The standard
EasySolar-II GX factory setting of the 'Bulk
protection' mode is switched on. The
'Bulk protection' mode can be switched
off with help of VEConfigure only.
The battery is not completely charged. Charging current excessively high,
causing premature absorption phase.
Set the charging current to a level
between 0.1 and 0.2 times the battery
capacity.
Poor battery connection.
Check the battery connections.
The absorption voltage has been set to
an incorrect level (too low).
Set the absorption voltage to the correct
level.
The float voltage has been set to an
incorrect level (too low).
Set the float voltage to the correct level.
The available charging time is too short
to fully charge the battery.
Select a longer charging time or higher
charging current.
The absorption time is too short. For
adaptive charging this can be caused by
Reduce the charging current or select the
'fixed' charging characteristics.
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Zweeds als bijlage per email.

De handleiding is 2.84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info