661559
16
Verklein
Vergroot
Pagina terug
1/60
Pagina verder
16 090134.01
Inverter type IV60012, IV60024, IV100012, IV100024, IV150012, IV150024, IV200012, IV200024, IV300012, IV300024
5 Using
Switch the inverter on with the ON/OFF switch on the front panel.
The inverter can now provide power to the users. Switch in more
than one user one at a time to prevent the inverter having to pro-
vide the switching on current for all users at the same time.
5.1 ON/OFF switch
The ON/OFF switch only switches the control current in the
inverter on or off. It does not switch off the power supply to the
inverter. The inverter works within the following minimum and
maximum voltages:
12 Volt model: 10 to 16 Volts
24 Volt model: 20 to 32 Volts
The inverter can only supply the quoted power if the voltage
supply is within the above limits.
5.2 LED indicators
BATT VOLTS
This LED bar shows the voltage at the battery terminals of the
inverter.
This voltage is near enough the same as the battery voltage
when there is a low input current. This voltage is less than the
battery voltage when there is a high input current due to voltage
losses in the battery wires and at the connections.
The situation is good when the indicator is in the green area. If
the indicator is in the bottom or the top part of the red area the
inverter can switch itself off.
LOAD% WATT
This shows the power supplied by the inverter to the users as
a percentage of the nominal power. This indicator may only be
in the green or orange area during continuous loading. A brief
period of slight overloading whereby the indicator enters the red
area is permitted. Where there is lengthy or extreme overload-
ing the indicator will flash red and the inverter will then switch
itself off.
Situation if one of the following LEDs is on:
BATT Hl
The inverter has switched itself off because the battery voltage
was too high. The inverter will switch back on automatically when
the voltage has dropped below the maximum value again.
BATT LO
The inverter has switched itself off because the battery voltage
was too low. The inverter will switch back on automatically when
the voltage has risen above the minimum value again.
TEMP Hl
The inverter has switched itself off because the temperature of
the inverter was too high. This can have been caused because
the inverter had to supply more than the nominal value or
because the inverter has been installed in a space where the
heat cannot be dissipated properly. The inverter will switch back
on automatically when it has cooled down.
OVERLOAD
The inverter has switched itself off because the output is over-
loaded or has short-circuited.
Overloading less than 150%
The LED flashes and the inverter will first automatically attempt
a restart 3 times. If the overloading is still too high at the third
attempt the inverter will no longer be switched on automati-
cally.
Overloading more than 150% (short-circuiting)
The inverter will be switched off and will no longer restart auto-
matically.
Switching the inverter on again
First solve the overloading problem. Switch the ON/OFF switch
on the inverter to OFF and then back to ON.
Or press the key OFF/RESET on the remote control panel.
5.3 Limitations of use
The inverter is intended exclusively to provide those electrical
and electronic appliances that can be connected directly to the
230 Volt network on shore with energy.
The power consumed continuously by these appliances must
not be greater than the nominal power of the inverter. See the
technical data for the nominal power.
Note that the power supplied is given for some appliances. The
power consumed can be considerably more!
For instance, the power consumed by a microwave oven is
about 1.5 times the power supplied.
It is possible that a motor will not start even though this motor
consumes less power than the inverter can supply. Check the
voltage shown on the ‘BATT’ LED bar while trying to start the
motor. If the voltage drops to less than 11 Volts the connections
to the battery could be poor or the battery could be insufficiently
charged.
If this is not the case a larger battery must be installed.
Power Save Mode
The Power Save Mode is not suitable for all appliances!
If an appliance can only be switched on when the network
voltage is already present then the Power Save Mode must be
switched off. Remember here equipment that is switched on and
off by means of a push button rather than by an on/off switch
directly in the voltage line.
16

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Vetus IV300012 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Vetus IV300012 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 3,41 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info