A. Massachusetts Safety Information
The Stardance Direct Vent Room Heater, Model Nos. SDDVT-
IFT-BD, SDDVT-IFT-BM, SDDVT-IFT-BS, SDDVT-IFT-CB,
SDDVTBSB, SDDVTBSSB, SDDVTBDSB, SDDVTBMSB, is
a vented gas appliance listed to the ANSI Standard Z21.88-
2019 and CSA 2.33-2019 for Vented Room Heaters, and
CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Stardance Direct Vent Room Heater must
conform with local codes, or in the absence of local codes, with
National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition
and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate
this appliance for altitude. Maintain the manifold pressure at 3.5
inches w.c. for Natural Gas and 10 inches w.c. for LP gas at
maximum input.)
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases unless a certied kit is used.
Installation and replacement of gas piping, gas utilization
equipment or accessories, and repair and servicing of
equipment shall be performed only by a qualied agency,
preferablyNFIorWETT(Canada)certied.Theterm“qualied
agency”meansanyindividual,rm,corporation,orcompany
that either in person or through a representative is engaged
inandisresponsiblefor(a)installationorreplacementofgas
piping,or(b),theconnection,installation,repair,orservicing
of equipment, who is experienced in such work, familiar
with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
TheStardanceDirectVentRoomHeatershouldbeinspected
beforeuseandatleastannuallybyaqualiedserviceagency.
It is imperative that control compartments, burners, and
circulatingairpassagewaysoftheappliancebekeptclean.
The Stardance Direct Vent Room Heater and its individual shut-o󰀨
valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2
psig (3.5 kPa).
The Stardance Direct Vent Room Heater must be isolated from the
gas supply piping system by closing its individual manual shuto󰀨
valve during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig.
An accessible tap is located above the pilot/On-O󰀨 knob for checking
the inlet pressure.
‘Direct Vent’ describes a sealed combustion system in which
incoming outside air for combustion and outgoing exhaust enter
and exit through two separate concentric passages within the same
sealed vent system. The system does not use room air to support
combustion. The Direct Vent system permits the gas appliance to
be vented directly to the outside atmosphere through the side of the
house or vertically through the roof. Conventional venting systems
(Natural Vent) take air from the room for combustion and vent the
exhaust vertically through the roof to the atmosphere.
This appliance is approved for bedroom installations in the U.S.
and Canada.
This appliance may be installed in an aftermarket* manufactured
(mobile) home, where not prohibited by state or local codes.
WARNING: Operation of this heater when not connected to a
properly installed and maintained venting system can result in
carbonmonoxide(CO)poisoningandpossibledeath.
The Stardance Direct Vent Room Heater, when installed, must
be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code ANSI/NFPA
70, (latest edition), or of the current Canadian Electrical Code C22.1.
Duetohightemperaturesthisapplianceshouldbelocatedout
oftra󰀩candawayfromfurnitureanddraperies.
WARNING: This appliance is hot while in operation. Keep
children, clothing, and furniture away. Contact may cause
burnsorignitionofcombustiblematerials.
Childrenandadultsshouldbealertedtothehazardsofhigh
surfacetemperaturesandshouldstayawaytoavoidburnsor
clothing ignition.
Youngchildrenshouldbecarefullysupervisedwhentheyare
in the same room as the appliance. Toddlers, young children
andothersmaybesusceptibletoaccidentalcontactburns.A
physicalbarrierisrecommendedifthereareatriskindividuals
in the house. To restrict access to a stove or stove, install an
adjustablesafety gatetokeeptoddlers,youngchildrenand
other at risk individuals out of the room and away from hot
surfaces.
A barrier is designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
Ifthebarrierbecomesdamaged,thebarriershallbereplaced
withthemanufacturersbarrierforthisappliance.
Clothingorotherammablematerialsshouldnotbeplaced
on or near the appliance.
Any safety screen, glass or guard removed for servicing an
appliancemustbereplacedpriortooperatingtheappliance.
Theapplianceareamustbekeptclearandfreefromcombustible
materials,gasoline,andotherammablevaporsandliquids.
The flow of combustion and ventilation air must not be
obstructed.Theinstallationmustincludeadequateaccessibility
and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass panel
removed,crackedorbroken.Replacementofthepanelshould
bedonebyalicensedorqualiedserviceperson.
Donotusethisapplianceifanyparthasbeenunderwater.
Immediatelycallaqualiedservicetechniciantoinspectthe
appliance and to replace any part of the control system and
anygascontrolwhichhasbeenunderwater.
Donotburnwood,trashoranyothermaterialforwhichthis
appliance was not designed. This appliance is designed to
burneithernaturalgasorpropaneonly.
Thisgasappliancemustnotbeconnectedtoachimneyue
servingaseparatesolid-fuelburningappliance.
CAUTION:Labelallwirespriortodisconnectionwhenservicing
controls. Wiring errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
* Aftermarket: Completion of sale, nor for purpose of resale, from
the manufacturer.
1 1 Important Safety Information
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Vermont Castings Stardance Series bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Vermont Castings Stardance Series in de taal/talen: Engels als bijlage per email.

De handleiding is 7.69 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Vermont Castings Stardance Series

Vermont Castings Stardance Series Gebruiksaanwijzing - Français - 54 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info