A. Sample of Serial Number / Safety Label
LOCATION: UNDER ASH LIP, PULL OUT TO VIEW
NOTE: Clearances may only be reduced by means approved by the regulatory authority having
jurisdiction
and Welcome to the Vermont Castings Family!
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and operating
instructions.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling.
WARNING - For Mobile Homes: Do not install in a sleeping room. An outside
combustion air inlet must be provided and unrestricted while unit is in use. The structural
integrity of the mobile home floor, ceiling and walls must be maintained. The insert must
be properly grounded to the frame of the mobile home. A complete relining of the chimney
system with a 6 inch (152mm) diameter listed stainless liner is required. Must be
equipped with a spark arrestor cap. Outside Air comes standard on the insert and must be
installed before operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to national
and/or local codes. Do not remove brick or mortar to accommodate insert. Installation
requires a 5 foot minimum length of a starter pipe into existing chimney with airtight face
seal. A full reline with listed liner strongly reccomended.
Install only on a non-combustible hearth.
Approved for installation and use in factory built zero-clearance fireplaces conforming to
minimum fire chamber specifications. A complete relining of the chimney system with a 6
inch (152mm) diameter listed stainless liner is required.
In Canada a full length 6 inch (152mm) S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use,
creosote buildup may occur rapidly.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route
power cord away from unit. Do not route cord under or in front of appliance.
Electrical Rating: 115 VAC 1.4 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on hearth (firebrick).
Do not
overfire. If heater or chimney connector glows, you are overfiring.
Operate only with doors
closed. Open only to add fuel to the fire. Replace glass only with 5mm ceramic available
from your dealer.
Minimum Clearances To Combustible Material
Masonry, Heat Circulating & Factory-Built
USA ONLY
A Sidewall to Fuel Loading Door 13.5 in.
B Mantel to the Bottom of the Appliance 47.75 in.
C Top Trim to the Bottom of the Appliance 34.75 in.
D Side Trim to Fuel Loading Door 13 in.
E Hearth Extension from Glass 16 in.
F H
earth Extenson from Fuel Loading Door
8 in.
Refer to Clearances on other label for Canada
Models:
MONTPELIER II
DO NOT REMOVE THIS LABEL
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
061WN100E
061WN100S
HOT WHILE IN
OPERATION DO NOT
TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE
NAMEPLATE AND INSTRUCTIONS.
CAUTION:
Factory-Built Floor
Protection under Hearth
Extension
Thermal & Ember Protection
Floor height 0 to 4.5 inches below
Insert Base: Materials with R value of
2.9 required.
Ember Protection Only
Greater than 4.5 inches below Insert
Base.
LISTED ROOM HEATER, SOLID FUEL TYPE
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
Made in U.S.A. of US
and imported parts.
Mfg by:
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 crib wood particulate emission standards for single bur rate heaters. The
single burn rate wood heater is not approved for use with a flue damper.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual
for further information. It is against federal regulations to operate this wood heater in a manner
inconsistent with the operating instructions in the owner’s manual.
352 Mountain House Road
Halifax, PA 99114
www.quadrafire.com
Serial No. / N° de série
HF
BARCODE LABEL
CONFORMS TO UL 1482-2011 and CERTIFIED TO ULC S628-93
2019 2020 2021
Side Wall
FF
Fuel Door
Insert
BB
Fascia
or Trim
Maximum Mantel Depth - 12 inch (305mm)
Mantel
Hearth Extension
AA
C
C
D
D
E
E
Test Lab &
Report Number
Mfg Date
Serial Number
Model Number
SAMPLE
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Vermont Castings Montpelier II bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Vermont Castings Montpelier II in de taal/talen: Engels als bijlage per email.

De handleiding is 10.37 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Vermont Castings Montpelier II

Vermont Castings Montpelier II Gebruiksaanwijzing - Français - 32 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info