Table of Contents
1. Precaution…………………………………………….…3
2. Preparation……………………………………………..6
z Standard Accessories……………………………6
z Part Names & Functions………………………..7
3. key features…………………….….………..…….……8
4. Use the Microscope………..……….………………..9
z Install Battery…………………….…..…………9
z Insert a MicroSD Card…………..……….……10
z Display Icons & Meanings…….……….….…...11
z Turn on the Microscope…….……....…….……12
z Turn off the Microscope…….…………………12
z How to Capture………………..…..………….13
z Download to Computer.….……..….…..………20
z Preview on Computer……….…………..…...20
z Charge Battery……….…………………………21
z Connect to TV…………………………………...23
5. Menu Introductions………………….……….……..…24
z Set Resolution………………………………...24
z Timer…………………………………….……….25
z Quality…………………………………………...26
z Sharpness…………………………………….....27
z Language………………………………………..28
z Power Save……………………………………28
z Frequency……………………………………29
z Date Stamp……………………………………...29
z TV out………………………………………….30
z Date/Time……………………………………..…30
z Format SD………………………………………31
z System Reset……………………………….…..31
z Version…………………………………………...31
EN
2
6. Specifications…………………..……………….…..…32
7. Computer System Minimum Requirement……….…32
8. Troubleshooting………………………………….……33
PortableCapture Pro Software Introductions……....34
Install Software……………………………………………..34
Start the Microscope……………………………………….35
Software functions………………………………..………36
z Capture photo……..………………………….…36
z Capture video………………….………………..36
z Timer……………………………………………..37
z Calibration……………………………………….38
z Measurement…………...……………………....42
z Change calibration………...…………………..43
z Draw and Text…………………….…………….46
Software Interface Introductions………………………..47
z Main Interface Icons……………………...…….47
z
Measurement Interface…………….……..……51
3
Welcome
Thank you for purchasing a Portable Stand Alone LCD
Digital Microscope.
Please take a moment to read through this manual. Its
contents will help you to get the best use of the smart
microscope.
1. Precaution
Before using the LCD Digital Microscope, please ensure
that you read and understand the safety precautions
described below. Always ensure that the LCD Digital
Microscope is operated correctly.
Never operate LCD Digital Microscope where
operation of such devices is restricted. Improper use
creates the risk of serious accident.
Do not try to open the case of LCD Digital Microscope
or attempt to modify LCD Digital Microscope in any
way. Maintenance and repairs should be performed
only by authorized service providers.
Keep LCD Digital Microscope away from water and
other liquids. Do not use LCD Digital Microscope
with wet hands. Never use LCD Digital Microscope
in the rain or snow. Moisture creates the danger of
fire and electric shock.
EN
4
If you notice smoke or a strange odor coming from LCD
Digital Microscope, turn the power off immediately.
Take LCD Digital Microscope to the nearest authorized
service center for repair. Never attempt to repair LCD
Digital Microscope on your own.
LCD Digital Microscope may become slightly warm
during use. This does not indicate malfunction.
If the exterior of LCD Digital Microscope needs
cleaning, wipe it with a soft, dry cloth.
5
FCC Notice
z This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference in a residential
installation.
CAUTION
To comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules, this device, when
needed, must only be connected to computer equipment
certified to comply with the Class B limits.
EN
6
2. Preparation
Standard accessories
LCD Digital
Microscope
AC adaptor Lithium Battery
USB cable TV cable CD
QSG Cleaning fabric
Calibration
chart
7
Parts Names & Functions
No. Functions No. Functions
1 3.5” LCD display 9 LED brightness dimmer
2 MicroSD card slot 10 Zoom +/-
3 Wheel B 11 5v DC in
4 Microscope tube 12 TV out
5 Object stage 13 USB port
6 Wheel A 14 Battery compartment
7 Wheel C 15 Battery charging indicator
8 Capture button
EN
8
3. Key Features
z 3.5 inches TFT panel
z 5M high quality image sensor
(up to 12M by interpolation)
z 10x-300x magnification
z Photo & Video
z Timer
z Measurement (when working on computer)
z Support MicroSD card up to 32GB
z Driver free to download for Windows XP SP2/
Vista/Win7/Win 8 and Mac OS 10.6 -10.8 (direct
plug-in, driver installation not required)
z Rechargeable Lithium Battery
EN
9
4. Use the Microscope
4.1 Install battery
1). Open the battery door by sliding its door latch..
2). Insert the lithium battery to the battery compartment
according to the polarities shown in the compartment.
Note: Before using the microscope, you must charge its
battery. Please refer to section 4.9 on how to
charge the battery.
EN
10
4.2 Insert a MicroSD Card (not included)
You must insert a MicroSD card (not supplied) to
record and store your pictures and videos.
Inserting the MicroSD memory card:
1) Turn off the microscope
2) Insert the MicroSD card into the MicroSD card
slot; gently press in until card is latched.
Note: Do not force the card into the slot; forcing may
damage microscope and the MicroSD memory card.
Align MicroSD card position (as marked) and try
again. The MicroSD memory card must be formatted
before capture.
See following instruction and Sec.5.2.5 Format SD.
11
4.3 Display Icons & Meanings
ICON Meaning
Still image capture
Timer capture
Captured image qty/total qty that
could be captured (based on the
current resolution)
MicroSD inserted
Current resolution
Battery electricity indicator
EN
12
Note: The icon displays can be switched on/off by
pressing Zoom Wheel downward vertically.
4.4 Turn on the Microscope
Press on/off button to turn it on.
4.5 Turn off the Microscope
1) Press on/off button
2) By Power Save. Please refer to Section 5.2.2 for
Power Save setup.
13
4.6 How to Capture?
14
1) Turn on the microscope, put object to be observed
onto the object stage.
2) Rotate Wheel A to bring the object near to the
microscope tube.
If wheel A is locked, rotate wheel C counter clockwise to
release the lock.
15
3) Rotate Wheel B to get fine focus.
4) When a clear focus got, rotate Wheel C clockwise
to lock the object stage.
16
5) Take Photo or Record Video
Press Capture button to take a photo or record video.
(1) Press Playback/Left to enter video mode as
follows. There is video icon on the left corner.
(2) Press Capture button to start recording video.
Press again to stop.
EN
17
6) Play Back
(1) Press Playback/Left to enter play back mode as
follows. There is review icon on the left corner.
(2) Press UP/DOWN to select among captured
pictures and video clips.
(3) Delete
At play back mode, press
to enter sub-menu as
follows, then confirm delete.
18
(4) Protect
At play back mode, press
to enter sub-menu as
follows, then confirm protect pictures from delete.
(5) Slide Show
At play back mode, press
to enter sub-menu as
follows, select interval time, and then confirm by OK.
EN
19
7) Color Mode
At preview status, press
to switch among
Color/Positive/Negative!
8) Zoom in: push Zoom Wheel upwardly
9) Zoom out: push Zoom Wheel downwardly
Note: The zoom ranges from 1x – 4.0x
20
4.7 Download to Computer
1) Connect the microscope to computer by USB cable.
2) Choose Mass Storage and then you can view stored
photos & videos.
4.8 Preview on Computer
1) Connect the microscope to computer by USB cable.
2) Choose PC Camera mode
3) Start PortableCapture software. Please refer to Part II
on how to use the microscope by PortableCapture
software.
Note: When working on computer, the button
functions are no longer valid, but most of functions
are available by PortableCapture software.
EN
21
4.9 Charge Battery
Before using the microscope, you must charge its
battery.
1. Plug the small end of the power adaptor into
the DC-in port located on the bottom side of
the unit. Then plug the other end of the power
adaptor into a standard AC outlet. The battery
indicator LED at the end corner of the unit will
be in red to show that the battery is charging.
2. When the battery is finished charging, the
battery indicator LED will be in off. Unplug the
unit.
3. You can now use your microscope for up to
two hours of continuous use. When the
battery is low, there will be low-power
indicator on the right down corner of the panel,
front LED light will become weak and image
quality becomes poor. Then you have to
connect the power adaptor and plug it in to
recharge the battery.
22
4.10 Connect to TV
1. Insert the 1/8-inch plug on the end of the supplied
video cable into the microscopes Video port.
2. Insert the RCA plug on the video cable into one of
your television’s yellow video input connectors.
Refer to your television’s manual for more
information on locating these connectors.
3. Turn on the television. If necessary, switch your
television to the appropriate input channel. Items
that you magnify appear on the television screen.
EN
23
5. Menu Introductions
5.1 Main Menu
Press
to enter main menu as follows:
Here you can setup Resolution/Timer/Quality/Sharpness.
5.1.1 Set Resolution
1) From the main menu, choose Resolution and
select a resolution between VGA/1.3M/3M/5M/8M/12M.
2) Press OK to confirm selection.
EN
24
5.1.2 Timer
1) From the main menu , choose Timer and then
enter Timer setup:
Frames: input quantity of frames you want to take by
UP/DOWN and LEFT/RIGHT.
The above setup means 32 frames.
Interval: input interval time between frame capture
by UP/DOWN and LEFT/RIGHT.
The above setup means interval time is 15 seconds
between each two captures.
25
3) Press OK to confirm selection and press Menu Setup
back to preview status. Then press Capture (8) to
start auto capture. When at auto capture status, there
is
at the left corner of the screen.
4) When all frames captured, microscope will return to
normal preview.
5) If you need to stop auto capture during the capture
process, press Capture one time.
Interval capture is only effective in still image capture
mode.
5.1.3 Quality
From the main menu, choose Quality and then
select among Super Fine/Fine/Normal.
The three selections will result in different image
compress ratio.
26
5.1.4 Sharpness
From the main menu, choose Sharpness and
then select among Super Fine/Fine/Normal.
5.2 Main Menu
Press
to enter main menu I, and then press LEFT
to enter Main Menu as follows:
Here you can setup Language/Power Save/
Date Stamp/TV Out/Date and Time/Format SD/
System Reset/Version.
27
5.2.1 Language
From the main menu , choose Language and then
select a target language by UP/DOWN.
5.2.2 Power Save
1) From the main menu , choose Power Save and
then select among the following a target time for the
microscope to power off without key operation.
EN
28
5.2.3 Frequency
From the main menu , choose Frequency to enter the
following menu:
Set up frequency by up/down.
5.2.4 Date Stamp
1) From the main menu , choose Date Stamp to
enter the following menu:
2) Select Date/Time, Date or Off.
Date/Time: both date and time will be marked on
images taken.
Date: on date will be marked on images taken
Off: None of date and time info will be marked on
images taken.
29
5.2.5 TV Out
From the main menu , choose TV Out and then
select, between NTSC and PAL, the correct mode
compatible with your TV.
5.2.6 Date/time
From the main menu , choose Date/Time to setup
date and time.
1) Setup date and time by LEFT/RIGHT/UP/DOWN
2) Setup date mode among YY/MM/DD, DD/MM/YY,
and MM/DD/YY.
30
5.2.7 Format SD
From the main menu , choose Format SD to
format the MicroSD card inserted.
5.2.8 System Reset
From the main menu , choose Sys. Reset to reset
the system back to default.
5.2.9 Version
From the main menu , choose Version to view the
current machine version.
31
6. Specifications
Image sensor: 5M high quality Image Sensor
Magnifications: 10x-300x
Resolutions: 12M, 8M, 5M, 3M, 1.3M, VGA
Lens: High quality microscopic lens
Display: 3.5inches TFT panel, 4:3 ratio
Light sources: 8 LEDs with adjustable brightness
Power sources:
Li-ion 3.7V / 1050mAh battery
Working time: 2 hours; Charging time: 5 hours
Frame rate: 30fps
Adaptor: Input:100-240V, 50/60Hz; Output: 5V, 1A
OSD languages:
English/German/French/Spanish/Italian/Portuguese/J
apanese/Chinese Simple/Chinese traditional
Software languages: English/German/French/Spanish/Russian/Italian/Port
uguese/Dutch/Polish/Japanese/Korean and Chinese
Image Measurement: By software
Size: L155mm*W112mm*H230mm
Weight: 780 gm.(with battery)
7. Computer System Minimum Requirement
Operating system Windows XP SP2/Vista/Win7/Win8 , Mac 10.6 -10.8
CPU Pentium 11 or above
RAM 256MB
Interface USB port2.0
EN
32
8. Troubleshooting
Problems Solution
The unit does not turn on. Charge the battery.
The screen is blank.
Ensure that the power is on.
Charge the battery.
Verify that the item you want to magnify is
Positioned correctly under the lens.
There are smudges or
blemishes on the screen
Clean the screen and lens carefully with soft
fabric
Microscope is connected
to a television, but no
image appears on the
television screen.
Ensure that the television is on.
Switch to the appropriate video input channel on
your television.
Ensure that the video cable is securely connected
to the Microscope Video-out port and plugged
into the correct video input on your television.
The battery indicator LED
is not in red, even though
the power adaptor is
connected and plugged
into a wall socket.
-or-
The battery is not
charging.
Plugged into the Microscope’s DC-in port.
Ensure that the outlet has power and is not
malfunctioning. If the outlet is connected to a wall
switch, make sure that the switch is on.
EN
33
PortableCapture Pro Software
Introdcution
Install the software
Insert the driver CD into CD-ROM Drive and this will
automatically display the following interface:
1. Install the PortableCapture Pro software
Click PortableCapture software and then reboot the
system when asked.
2. You can also browse the User manual in PDF format
and the CD contents by choosing the corresponding
menus.
34
3. Start the Microscope
Connect your Microscope to your PC USB port as shown
on Page20, start the software by clicking the
icon generated on the desktop after
installation and you will see the following screen pop up.
35
4. Software functions
Capture Photo
a. Click ‘Photo’ shortcut icon
in the main menu
bar.
b. Click ‘Capture > Photo’.
Capture Video
a. Click ‘Video’ shortcut icon
in the main menu
bar.
b. Click ‘Capture > Video’.
36

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Veho VMS-005-LCD Standalone USB Microscope bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Veho VMS-005-LCD Standalone USB Microscope in de taal/talen: Engels als bijlage per email.

De handleiding is 3,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Veho VMS-005-LCD Standalone USB Microscope

Veho VMS-005-LCD Standalone USB Microscope Snelstart handleiding - Deutsch - 2 pagina's

Veho VMS-005-LCD Standalone USB Microscope Gebruiksaanwijzing - Deutsch - 56 pagina's

Veho VMS-005-LCD Standalone USB Microscope Snelstart handleiding - English, Français, Italiano, Português, Espanõl - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info