Congratulation on purchasing your new stove
Varde Ovne A/S is a Danish company specializing in functional, environmentally friendly and
designed quality stoves.
Index
Welcome and index Page 2
Technical specifications Anholt Page 3
Technical specifications Bornholm Page 4
Technical specifications Fur Page 5
Technical specifications Langeland Page 6
Technical specifications Femø Page 7
Technical specifications Bogø Page 8
Regulations and approval Page 9
Flooring and distance Page 10
Installations distances Page 11
Chimney Page 12
Air supply Page 13
How to light and stoke a fire Page 14
How to light and stoke a fire Page 15
Operation Page 16
Vermiculit e Page 17
How to choose the wood Page 18
Maintenance Page 19
Troubleshooting Page 20
Spare parts Page 21
Testcertificate (RRF) Page 22
Warranty Page 23
3
Technical Specification Anholt
Model Anholt
Height (mm) 1005
Wide (mm) 458
Depth (mm) 352
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front = 110cm
4
Model Bornholm
Height (mm) 1005
Wide (mm) 458
Depth (mm) 352
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front = 110cm
Technical Specification Bornholm
5
Model Fur
Height (mm) 1005
Wide (mm) 448
Depth (mm) 350
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front = 110cm
Technical Specification Fur
6
Model Langeland
Height (mm) 1005
Wide (mm) 448
Depth (mm) 350
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front = 110cm
Technical Specification Langeland
7
Model Femø
Height (mm) 1005
Wide (mm) 487
Depth (mm) 352
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front=110cm
Technical Specification Fe
8
Model Bogø
Height (mm) 1005
Wide (mm) 458
Depth (mm) 352
Weight (kg) 85
Effect 3-7 kW
Nominal Output 5,5 kW
Heated area 30-105m²
Efficiency 80 %
EEI 107
Flue gas data 273°C at 25°C, 12Pa.
Combustion Chamber : (H x W x D):
245-360/300/280mm
Flue outlet:
Ø 15cm (Mounting height top: 99cm)
Distance to non inflammable:
5-10cm (Recommended)
Distance to inflammable wall and materiels:
Rear = 30cm, Sides = 45cm, In front = 110cm
Technical Specification Bogø
9
Important!
Before lighting up your Varde Stove for the
first time, we recommend that you read these
instructions carefully and contact your local stove
vendor or building authoorities to inquire about
existing regulations regarding the intallation of
stoves. Please follow these regulations closely.
Inspection of installation
It is very important that the installation is in-
spected by a qualified chimney sweeper before
the stove is used the first time.
Regulations
All local regulations as well as National and
European, should be adhered to when instal-
ling your stove.
All Varde Ovne stoves are closed fireplaces.
The stove is designed for intermittent com-
bustion and can be connected to a chimney
used by other fireplaces, as long as the app-
ropriate rules and regulations are adhered to.
This Varde Stove
Has passed the
Danish /European Standard DS/EN 13240
Norwegian (NS) and the
German (Stufe 2) test , and have thereby proved
to be a environmentally friendly product.
Proffesional installation
We recommend that you consult with the
dealer where you purchased the stove or an
other competent installer, as there may be
specific things to consider during the installa-
tion. You should also reseive the applicable
rules for installing the stove and follow them.
Please Note!
You are by law required to register your stove at the local chimney-sweeper.
Until installation keep the stove dry and not to cold. The stove cannot stand moisture.That an
existing chimney, not necessarily is effective enough for a new modern stove.Vermiculite is a
very porous material, therefore handle with care. When refilling the stove, put the wood careful-
ly, use the glove.
Jan Meldgaard
CEO
Varde Ovne
EC declaration of confirmaty.
MANUFACTURER
Name: Varde Ovne A/S
Adress Soldalen 12, DK-7100 Vejle, Denmark
Stove Inspection
Name: RRF
Adress Im Lopperfeld 34b, 46047 Oberhausen, Germany
Product Varde
Product type Anholt, Bornholm, Fur, Langeland, Femø and Bogø
Type code Heating stove, suitable for intermittent combustion
Standard Costruction products (89/106/EC/) standard used
EN 13240
Application Residential Heating
Fuel Wood
Special conditions Non
CE-Markning
Issued 2017
Nominal Output 5,5 kW
Fuel type Wood
Fluegas temperature 273 °C
Efficiency 80 %
Co-release 0,08 %
10
Flooring:
If the floor on which the stove is to be placed is inflammable, the floor must be covered with non
-flammable material, such as steel or glass plate, floor tiles or artifical slate, covering an area of
at least 15 cm from the sides of the stove and at least 30 cm from the front of it. Regarding the
Weight Steel Stove
Varde Anholt, Bornholm, Fur, Langeland, Bogø og Femø 85 kg
Installation distance:
If walls are non-inflammable, the stove can be placed closer to them. However, we recommend
a minimum distance of 5-10 cm, to allow for cleaning behind the stove. The cleanout gate must
be accessible. Optimal combustion can only be obtained if fresh air is constantly admitted. It is
important, therefore, to ensure that this is the case. The best way to provide a steady flow of
fresh air is by installing 1-2 air vent’s in the room where the stove is situated. (One in each side
of the room).
According to existing regulations, stoves must be placed with the following minimum distances
in mm to inflammable walls and materials. The distance from the outer edge of the flue pipe to
inflammable material is descriped as for horizontal Flue 300mm and the distance for vertical flue
is 225mm
11
Varde Femø, Bogø, Anholt, Bornholm, Langeland og Fur
A 300 mm C 450 mm
B 225mm D 1100 mm
Installation distance
The stove must in accordance with applicable rules comply with the following minimum distan-
ces from inflammable walls and materials:
Sides : 45cm
Rear : 30 cm
Distance to furniture : 110 cm
Fur and Langeland
Femø and Bogø
Anholt and Bornholm
12
The chimney:
Always use a chimney with a diameter of at least 15 cm. This corresponds to a clear of 175 cm2.
Make sure the chimney is of a sufficient height, that it draws well and that smoke does not both-
er your neighbours.
We recommend that you fit your chimney with a damper, allowing for draft control. This may
prove particularly important on windy days.
Note: the damper must never shut off draught completely always allow at least 20 cm² free
passage through the chimney.
With nominal usage the stove has tested a flue gas flow of 4,9g/second and with a flue gas tem-
perature of 328°C in a room of 25 °C.
Varde stoves are always fitted with a smoke plate which redirects smoke to make its way to the
chimney as effectively as possible. This ensures that the heat from the smoke is emitted inside
your home rather than outside it. The smoke plate is moveable and placed on top of the Vermic-
ulite fire brick side plate. You should make sure that it is pushed all the way back against the
back wall of the combustion chamber.
Draught conditions
Consult your local stove dealer about how best to adjust the draught in your chimney.
Hight of chimney
If in doubt, contact your local stove dealer. He will be able to inform you of the correct hight.
Connection of Flue pipe:
The Stove is mounted with Flue adaptor on the top.
Information about the new cast iron adapter.
Your stove is equipped with the new cast iron adapter from Varde Ovne.
The adapter is suitable for smoke pipes with inner diameter on 150 mm.
If you need it, it’s now possible for you to make a condensate drain-hole in the adapter.
Carefully punch a chisel or the like through the adapter in the outer groove, at the arrow
mark. This way you can establish a condensate drain hole in the adapter.
Arrow mark for the hole. Now the condensate hole is
ready.
Carefully punch a hole with a
chisel or the like.
13
Continual fresh air
A continual supply of fresh air is required in the
room in wich the stove is situated. This can be
achieved by installing 1-2 vents, whilst also ensur-
ring that these can not be blocked. The quantity of
air used for burning,
is approx. 14 m³ / h.
Tertiary air
Is constantly added air, which makes the
stove brun even cleaner, and lowers the
content of tar and soot in the combustion
process to an absolute minimum. At opti-
mal combustion settings, glass and com-
bustion chamber will be burnt completely
clean, and the remaining amount of ashes
will be minimal.
Overheating
Occors if too much wood is placed in the
stove or if the combustion receives too
much air.
Combustion air throttel
Push the throttel towards
right for opening.
Combustion /Secondary air
Pre-heated air for the combustion process,
the amount of wihich can be altered accor-
ding to the desired room temperature and
the effectiveress of the chimney. A high
level of chimney draught requires a lesser
intake of combustion air.
Combustion air throttel
Push the throttel towards
left for closing.
Ignition air
On Ashpan - Open
Ignition air
On Ashpan - Closed
This option is only for use
at lightning up. As soon as
the fire has a good grip in
the woodrembermber to
close again.
Max height of firewood
14
How it works
The Bottom grate
The bottom grate is situated at
the bottom of the combustions
chamber. The ash can fall
through the grate and into the
ash pan.
Combustion air throttel
Push the throttel towards
right for opening.
Ignition air
On Ashpan - Open
Ignition air
On Ashpan - Closed
15
How to light and stoke a fire:
The first time you light up the stove the enamel will temper, and give off some smoke and a
slight smell. We recommend that you leave doors and windows open, as airing the room will
make the smell disappear. This tempering softens the enamel making it susceptible to damage.
Therefore exeercise caution and avoid touching the enamel. Likewise we recommend opening
the door to the stove at regular intervals for the first hours to prevent the insulations rope from
sticking to the enamel.
Never use highly inflammable fluids such as methylated sprit and petrol for lighting up!
We recommend a ”Top-Down” lightning, where you light the wood in the upper area of the com-
bustions chamber and not in the ground. This method is the most environmental metod to light
a fire. The metod will keep the glass clean. In the combustion chamber you make a cross () of
4 small pieces of wood with a small distance between each one of them(0,7-1,1kg). On top you
of them you make another cross () of 8-12 smaller sticks (0,4-0,7 kg.), on top of this firewood
and in between use 2-3 kildning blocks. In total approximate 1,5kg og woods. A thin layer of
ashes at the bottom of the stove makes lighting up a fire easier.
Before lighting up the stove, open ignition air on the ash-pan for access of primary air .The
throttle for the Combustion Air is drawn towards the right and hereby fully openes for combusti-
on air.
When the fire burns remember to close the the Ignition air again, or the stove and chimney
might become overheated and will invalidate the warranty. Also make sure the ash pan is closed
propper.
Hereafter the combustion air are ajusted to the need of heat. Be aware not to close to much for
the air supply, otherwise the fire will die, the fire must alway be bright and clear.
In most instances, however, you will have to achieve the best combustion air settings your-
self, as the height and draught of your chimney, as well as the quality of the firewood are deci-
sive factors in determining how your particular stove is best set.
If the stove nominal heat output is too large compared to the heat demand, you can reduce the
output as descriped here:
- use a smaller amount of wood than usual, for example. 0,9 to 1.2 kg. and preferably consist-
end of 3-4 smaller pieces of wood. Apply full air to ignite the wood properly, then you can
reduce the combustion air, perhaps down to approx. 60%. Be aware not to close to much for the
air supply, otherwise the fire will die, the fire must alway be bright and clear.
With this method it, (depending on the chimney, wood quality, etc. is possible to reduce the
stove heat output from a nominal 5,5 kW down to maybe 3 to 3.5 kW.
Please be aware that it can lead to poor combustion, if you regulate too much down the com-
bustion air, resulting in a lower efficiency and increased emission levels in the smoke.
(increasing pollution).
Tertiary air
If you are wondering why your stove is fitted with an gap in the rear vermiculite plate in the
combustion chamber, with small holes through the back steel plate, where air is running through
into the combustion chamber. This is merely a consequence of our newly developed combustion
system. We refer to these air ducts as the ‘tertiary air’, and will prove helpful as you install your
new Varde stove.
When refilling the stove with wood, we recommend opening the stove door only once embers
are left in the combustion chamber. Opening the door whilst the flames are still burning and
producing smoke and gas, might cause smoke to slip into the room instead of up the chimney.
Should you have some issuses with the lightning or the function, see section on troubleshoo-
ting.
16
Operation
1
2
3
4
5
6
7
8
10
9
1. Bottom grate
2. Log retainer
3. Vermiculit plates
4. Ash pan
5. Cast iron door
6. Steel top
7. Throttel for ignition air
8. Combustion air throttel
9. Storage
10. Site panels
11. Storage door (only on Bornholm, Bogø and Fur)
11
17
Vermiculite
The plates in the Combustion Chamber are Vermiculite plates and will aventually be
worn, - as will the smoke plate. Should you accidentally breah the plate, for instance by hitting it
hard with a piece of wood, this does not effect the quality of the combustion. You need not re-
place the plate until the gap is 5 mm wide.
Vermiculite
A special non-flammable material. The vermiculite fire plates both isolate and protect the stove
from attrition. Vermiculite plates and deflector not covered by the warranty. Vermiculite is a
very porous material, therefore handle with care. When refilling the stove, put the wood careful-
ly, use the glove.
Only use original parts from Varde Ovne A/S
How too replace the Vermiculite
1. Remove Grate plates (5)
2. Deflector, lift easily, bottom bag end are tilted forward, take down.
3. The left side plate can be easily liftes up and rotated out.
4. Right side plate can be easily lifted up and rotated out.
5. The Rear cover is liftes up and out of the stove.
Mounting of new Vermiculite plates follow point 5 towards point 1.
Vermiculit set,
Item no.: 100882
1. Deflector plate
2. Left side plade
3. Right side plade
4. Rear cover
5. Grate Plates
1
2
3
4
5
18
The new stove
The first time you light up the stove the ena-
mel will temper, and give off some smoke and
a slight smell. We recommend that you leave
doors and windows open, as airing the room
will make the smell disappear. This tempering
softens the enamel making it susceptible to
damage. Therefore exercise caution and avoid
touching the enamel. Likewise we recommend
opening the door to the stove at regular inter-
vals for the first hours to prevent the insulati-
ons rope from sticking to the enamel.
What kind of wood to use?
Generally, beech wood is considered the best
type of wood for burning. It burns evenly
without producing much smoke and ashes are
clean and take up little space. Ash, birch and
maple wood are fine alternatives.
How big the firewood?
Split firewood with a diameter larger than 10
cm. Use firewood with a length on 20-25 cm.
The use of larger quantities of fuel than recom-
mended in the tabel belove will overtax the
stove and resulte in increased temperatures in
the chimney as well as a lowered efficiency.
This may cause damage to both chimney and
stove, and the annulment of the warranty. Also,
never use toxic materials such as chipboard,
painted or impregnated wood.
Lightnings sticks
Length: 20 25 cm
Wide 3x3 cm
Normal amounth: 10-15 sticks (approx. 1,5 kg)
Firewood
Length: 25-30 cm
Diameter: max. 10 cm
Normal amounth: 3-4 firwood (approx. 1,2kg)
The following optimal register and fuel quanitty settings are recommended(in case of similar chimney
draught):
Fuel Quanti-
ty
[kg]
Primary Air
open
[%]
Combustion
Air open
[%]
Nominal
Output
[kW]
Chimney
Draught
[PA]
Efficiency
[≥ i %]
Refill interval at
nominal output
[minuts]
1,2 0 (closed) ca. 60 5,5 12 80 ca. 45
What to burn.
This Varde Stove is tested and approved for
the burning of wood. Only dry wood with a
moisture content of maximum 21 percent and
the size to fit into the combustion chamber
should be used. The burning of moist wood
will result in an increased amount of tarry
soot, pollution and uneconomic fuel consump-
tion. Newly chopped wood contains about 60-
70 percent moisture, which makes it comple-
tely unsuitable as fuel. Allow newly chooped
firewood to dry in a open shed for a couple of
years before using it in the stove.
Do not use! - Consider the environment
Also, never use toxic materials such as
chipboard, painted or impregnated wood.
The use of larger quantities of fuel than re-
commended in the tabel belove will overtax
the stove and resulte in increased temperatu-
res in the chimney as well as a lowered effici-
ency. This may cause damage to both chim-
ney and stove, and the annulment of the war-
ranty.
Topdown Lightning of the fire
19
Maintenance
Like any piece of equipment in daily use, your stove needs maintenance.
The stove should only be cleaned when cold. Use a dry cloth for cleaning the exterior of the
stove.
Clean the interior regularly by removing ashes, soot and tar from the combustion chamber. The
smoke deflector plate should be removed for cleaning, as the reverse side will be covered in dirt
and soot. Finally check that the smoke pathway through the flue pipe and chimney is completely
clear. You should also inspect the rope seals in the door and ash pan for signs of wear. Replace
them if they no longer seal properly. Also, remember to lubricate the door hinges as required.
Glass pane
The glass pane should be cleaned using Varde Glas Cleaner, which is available at all DIY centres
selling Varde Ovne stoves.
Empty the Ash pan regularly. It can be emptied into your dustbin, as long as you make sure it
does not contain any hot embers. If in doubt about how to clean your stove, contact the dealer
where you bought your stove, or your chimney sweeper.
It is especially important to check the stove and the chimney for blockages after a long period of
non-use.
The enamelled surface of the stove may wear down in certain places if the stove is overheat-
ed. Worn surfaces can, however, be repaired with a special Senotherm® spray paint, available
from your local dealer.
The plates in the combustion chamber are vermiculite plates and will eventually become
worn, as will the smoke deflector plate. Accidental breakage of a plate, for instance by hitting it
hard with a piece of wood, will not affect the quality of the combustion. You do not need to re-
place the plate until the gap is 5 mm wide.
Only use original parts from Varde Ovne A/S
The door is equipped with a spring, which pulls the gate closed. This is a legal requirement in
many countries. The spring is fitted to the hinged side of the door but can be removed if you
prefer the door not to be spring-loaded.
Do not make any unauthorised changes to the stove.
All external parts of the stove become hot during use, and you should therefore exer-
cise due caution.
IMPORTANT!!
Chimney fires
Should your chimney catch fire, cut off the air supply to the stove’s combustion chamber and
contact the emergency service. (The majority of fires die out after the oxygen supply is cut off.)
You should subsequently contact your chimney sweeper, who will check your stove and chimney
for damage
20
Troubleshooting.
Smoke enters the room:
Not enough draugh in the chimney.
Inspect the smoke pipe or the chimney for blockage.
Clean the inside of the stove removing soot from the upper vermiculite / smoke
(Deflector) plate.
Make sure the hight of the chimney is correct.
The glass or the chimney soot up:
The wood is too moist.
Not enough secondary air is applied to the combustion process.
You may have shut off the supply of ignition air too aerly when lightning up the stove.
There always have to be clear flames in the combustion chamber.
The heat is emitted from the stove:
The wood is too moist (all energy goes into drying it) or of a poor quality.
Inspect the position of the smoke plate and make sure there is free passage for the
smoke.
The amount of combustion(secondary air) air is not enough.
Combustion is too intense:
Gaskets in the door or the ash-pan are no longer tight and need replacement.
The chimney draugh is too strongapply a valve in the chimney.
Inspect that the ignition air is closed.
The Shake grate is stuck:
Inspect the grate for jammed wood, nails or the like.
Make sure the lever is placed correctly.
Recycling
Packing
The packing is 100% recycleable.
Ceramic Glass
Ceramic glass tobe deposited at the local recycling center and sorted together with pottery and
porcelain.
Vermiculite
Vermiculite plates from the stove must be returned to the local recycling center.
21
Spare Parts
If Spare parts at any time should be needed, please chech the list below.
Log retainer, Artikel nr.: 100366
Top Cover steel Ø165 VO-Logo, Artikel nr.: 100701
Door Complete Cast Iron Artikel nr.: 100577
Glass, Artikel nr.: 100272
Glass Side Panel inside, Artikel nr.: 100883
Glass Side Panel exterior, Artikel nr.: 100884
Handle Complete, Artikel nr.: 100363
Ashpan Complete Black, Artikel nr.: 100364
Vermiculite Set, Artikel nr.: 100882
Sealing Rope 3 x 8 mm/2,0m, Artikel nr.: 100443
Sealing Rope Ø10/2,5 with glue 50 ml, Artikel nr.: 100351
22
23
Warranty
All Varde stoves go through a close quality inspection, and we take
pride in always delivering products of a consistent quality. This being
so, manufacturing faults may still occur, and on these we offer a 5
year warranty.
The warranty does not include:
· wearing parts, such as the Vermiculite plates in the combustions
chamber, the smoke plate, glass, gaskets, cast iron bottom and
shacking grate.
· Damages whichs occur as a consequence of misuse, such as over-
heating, incorrect installation, missing or wrong maintenance etc. (see
instructions earlier)
·Damages caused by external influence of a physical character.
·Cost of transportation in connection with warranty repairs.
·Assembling/reassembling in connection with warranty repairs.
·Compensation for following damages, including damage on other
objects.
Warranty conditions:
These instructions for use are also your proff of warranty. The war-
ranty will not take effect until vendor’s stamp, information about mo-
del, registration numer and date of purchase (invoice if possible)have
been applid below. In case of claims, please bring this proof of war-
ranty to your local vendor.
Model:
Reg.no.:
Date of
purchase:
Vendor’s stamp and signature
24
Soldalen 12, 7100 Vejle, Danmark, Tel. +45 7482 0003. vardeovne.dk
Typos may appear
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Varde Anholt bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Varde Anholt in de taal/talen: Engels als bijlage per email.

De handleiding is 1.33 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info