GENERAL
Carefullyread thefollowing important informationregarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations. The appliance
has been designed for use in the ducting version (air exhaust
to the outside Fig.1B),lteringversion (air circulation on the
inside – Fig.1A) or with external motor (Fig.1C).
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultane-
ously with an open replace or burner that depend on the air
in the environment and are supplied by other than electrical
energy, as the cooker hood removes the air from the environ-
ment which a burner or replace need for combustion. The
negative pressure in the environment must not exceed 4Pa
(4x10-5 bar).Provide adequateventilation in theenvironment
for a safe operation of the cooker hood. Follow the local laws
applicable for external air evacuation.
Before connecting the model to the electricity network:
-Control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualied
electrician.
-If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
2. Warning!
In certain circumstances electrical appliances may be a
danger hazard.
A)Do not check the status of the lters while the cooker
hood is operating.
B)Donot touch bulbs oradjacentareas,duringor straight
after prolonged use of the lighting installation.
C)Flambè cooking is prohibited underneath the cooker
hood.
D)Avoid free ame, as it is damaging for the lters and a
re hazard.
E) Constantly check food frying to avoid that the
overheated oil may become a re hazard.
F) Disconnec t the electrical plug prior to any
maintenance.
G)Thisapplianceis notintended for useby youngchildren
or inrm persons without supervision.
H) Young childrenshould be supervised to ensuretheydo
not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of re if cleaning is not carried out in
accordance with the instructions.
ThisapplianceconformstotheEuropeanDirectiveEC/2002/96,
Waste Electrical andElectronic Equipment (WEEE). By making
surethatthis appliance is disposedof in a suitablemanner, the
user is helping to prevent potential damage to the environ-
ment or to public health.
The
symbol on the product or on the accompanying pa-
perwork indicatesthat the appliance should not betreatedas
domestic waste, but should be delivered to a suitable electric
and electronic appliance recycling collection point. Follow lo-
cal guidelineswhen disposing ofwaste.For more information
on the treatment, re-use and recycling ofthis product, please
contact your local authority,domestic waste collectionservice
or the shop where the appliance was purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out
by specialised personnel.
Electric Connection:
This is a class I, appliance and must therefore be connected
to an eecient earthing system.
-The appliance must be connected to the electricity supply
as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal with the
N symbolwhile the YELLOW/GREEN,wiremustbe connected
to the terminal by the earth symbol
.
When connecting the appliance to the electricity supply,
make sure that the mains socket has an earth connection.
After tting the ducted cooker hood, make sure that the
electrical plug is in a position where it can be accessed easily.
If the appliance isconnected directly to theelectricity supply,
an omnipolar switch with a minimum contact opening of
3 mm must be placed in between the two; its size must
be suitable for the load required and it must comply with
current legislation.
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection
tube composed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the cooker
hood exhaust to the same conductor used to circulate hot air
or for evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease lter(s) (Fig.15)
so that the unit is easier to handle.
We recommend the use of anair exhaust tube whichhas the
same diameter as the air exhaust outlet hole. If a pipe with
a smaller diameter is used, the eciency of the product may
be reduced and its operation may become noisier.
In thecase of assembly ofthe appliance inthe suctionversion
prepare the hole for evacuation of the air.
Hood assembly:
-Remove the structure from the packaging and remove the
2 screws A to separate the upper part from the lower part
(Fig.2).
-Position hole template on the ceiling paying attention that
the arrow is positioned on the same side as the appliance
controls (Fig.3). Make 4, Ø8 holes in the ceiling and drive in 3
screwswithout completelytightening them. Payattentionnot
to insert thescrew into thehole marked with anX onthe hole
template (the screws and expansion plugs must be suitable
ENGLISH
EN
- 18 -
18

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw V-Zug DI-SL10 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van V-Zug DI-SL10 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans als bijlage per email.

De handleiding is 1,22 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info