Calibration
The thermometer is initially calibrated at the time of manufacture.
If the thermometer is used according to the use instruction, periodic
readjustment is not required. However, We recommends checking
calibration every two years or whenever clinical accuracy of the
thermometer is in question. Please send the complete device to the
dealers or manufacturer.
The above recommendations do not supersede the legal requirements.
The user must always comply with legal requirements for the control
of the measurement, functionality, and accuracy of the device which
are required by the scope of relevant laws, directives or ordinances
where the device is used.
A clinical summary and procedures for checking calibration are
available upon request.(Turn on the thermometer and press the power
button long time until entering into calibrate mode, software version
will be displayed.)
Direct Current
Disposal of this product and used batteries should be carried out in accordance
with the national regulations for the disposal of electronic products
Type B F applied part
Consult Accompanying Documents
LOT Batch Code
26
Troubleshooting
In Ear mode:
Temperature taken is
higher than 43.0
(109.4).
In Object mode:
Temperature taken is
higher than 100
(212).
Problem Solution
Read Temperature
Taking Hints thoroughly ,
then make sure the probe
cover and lens filter are
clean, then take a new
temperature measurement.
The thermometer could
not work due to low
battery.
Replace two new
alkaline batteries
size AAA.
Error message
Read Temperature Taking
Hints Thoroughly, then
check the integrity of the
probe cover and take a new
temperature measurement.
24
Remove probe cover in
object temperature mode.
25
In object temperature
mode, measurement
with probe cover.
In Ear mode:
Temperature taken is
lower than 32.0
(89.6).
In Object mode:
Temperature taken is
lower than 0
(32).
23
Storage and Transportation Temperature Limit:
-13 131(-25~55℃)
-25
55
Specifications
Ear/Object mode:
10~40(50~104), 15%~85%RH, non-condensing
00hPa ~ 1060hPaAtmospheric Pressure : 7
57*146*38mm
Approx.83grams(with batteries)
DC3V(2×AA battery)
Measuring range
Laboratory accuracy
Display resolution 0.1 or 0.1
Measure time Approximately one second
Operating temperature
range:
Storage and transport
temperature range
-25~ 55 (-13~131), 15%~95%RH, non-condensing
00hPa ~ 1060hPaAtmospheric Pressure : 7
Clinical accuracy
Dimension
Weight
Battery
Battery life Approx. 1 year/6000 readings
Measuring site Ear canal(Ear Mode)
Oral (This thermometer converts the ear temperature to
display its “oral equivalent.)
Reference body site
Operation mode Ear mode(Adjust mode)
Ingress protecting rating
IP22
Clinical bias0.08℃(0.14℉)
Clinical repeatability0.13℃(0.23℉)
Limits of agreement:0.73℃(1.31℉)
Shock withstands drop of 3 feet
Expected service life Three years
Ear mode: 32.0~43.0(89.6~109.4)
Object mode: 0~100(32~212)
Ear mode:
±0.2 (0.4) during 35.5~42.0 (95.9~107.6)
at 15~35 (59.0~95.0) operating temperature range
±0.3 (0.5) for other measuring and operating
temperature range
Object mode: ±4% or ±2(4) whichever is greater
Troubleshooting
Problem Solution
The ambient temperature
is not within the range
between 10 and 40
(50~104).
Place the
in a room for at least 30
minutes at room
temperature between
10 and 40
(50~104)
thermometer
The thermometer is
placed incorrectly
or unsteady.
The thermometer
showing a rapid ambient
temperature change.
The thermometer is not
functioning properly.
Read Illustration For
Use thoroughly and
take a new temperature
measurement.
Allow the thermometer
to rest in a room for at
least 30 minutes at
room temperature:
between 10 and 40
(50~104)
Unload the battery,
wait for 1 minute and
repower it. If the
message reappears,
contact the retailer
for service.
Error message
Take a measurement
until or appears
on the display.
Measurement before
thermometer is ready
Product Description
1. Probe Cover
2. Probe
3. Test Button
4. Button
5. Battery Cover
6. Setting Button
3
1
2
5
3
4
6
Electromagnetic Compatibility Information Electromagnetic Compatibility Information
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Unknown DET-1015b Infrared Ear Thermometer bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Unknown DET-1015b Infrared Ear Thermometer in de taal/talen: Engels als bijlage per email.

De handleiding is 4.36 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info