84
< Item Track Balance Checking > --- Item Track System Only (Display Only)
If this does not exist on the master, the master searches the slaves and collects the track data from the slave. The
collected data is deleted from the slave. Then the master shows the track balance.
< Item Track Additions > --- Item Track System Only (Display Only)
If the entered tracks do not exist on the master, the master searches the slaves and collects the track data from the
slave. The collected data is deleted from the slave. Then the master adds the tracks, but does not consolidate
them.
< Notes for Communication Error >
If a communication error occurs, one of "-- IRC BUSY --", "ECR#-xxx ERROR" or "ECR#-xxx BUSY"
(xxx = ECR machine number) is displayed, then;
- retry the communication by pressing CASH/TTL 25 key, or
- cancel the communication by pressing CL key, or
- make "New Track" by X2 key (if permitted by programming).
Item Track made by X2 key should be closed by NB key and Amount Track made by X2 key should be closed
by CHARGE key, then the track consolidation must be performed to avoid the tracks having same number on
the master and slave.
When CL key is pressed, depending on the cases, the master displays REQ.Z62-xxx or REQ.X62-xxx with
Item Track number and REQ.Z66-xxx or REQ.X66-xxx with Amount Track number and prints the message
on the journal.
When REQ.Z62(66)-xxx is displayed,
(This is displayed when the master collects the track data from the slave, but the slave does not delete it yet.)
1. Press CL key again to clear the error.
2. Then enter the track number with ITEM (AMOUNT) TRACK # key again to continue the track operation.
3. After the track operation is completed, take Z-62 (66) individual Item (Amount) Track report on the
ECR machine number xxx to delete the track data from that ECR to avoid the tracks having same number
on the master and slave.
When REQ.X62(66)-xxx is displayed,
(This is displayed when the master collects the track data from the slave and the slave deletes it but the
confirmation of such deletion is not sent to the master yet.)
1. Press CL key again to clear the error condition.
2. Then enter the track number with ITEM (AMOUNT) TRACK # key again to continue the track operation.
3. After the track operation is completed, take X-62 (66) individual Item (Amount) Track report on the
ECR machine number xxx in order to make sure that the track is deleted from the slave.