Up start & Settings
At delivery the burner is not adjusted and therefore has to be adjusted with a flue gas instrument at the first
start.
1. Fill the feed auger with pellets before it is connected to the burner by connecting the connection
cable of the burner to the auger. Let it run for a couple of minutes after it has been filled
(approx. 10-15min is recommended).Then run it exactly10 min in a plasic bag and measure the
weight. See figure 1 below.
In this case it was 1284 gram at 10 min.= 128 gram / min. This value is entered as shown in Figure 2
Figure 1 Figure 2
2. Press the right arrow on the display to the next menu in which you confirm the change with OK
button.
See below Figure 3. This procedure should you do if you change your pellets quality..
Power mode 1 may just be between 6-10 kW.
Power level 5 may only be between 15-20 kW.
Figure 3
3. To adjust amount of air and fuel for operation the flue gas instrument shall be used. Talk to your
installer.
Installation of right amount is important to obtain a good firing economy. Adjustment protocol should
also be left to the customer in writing.