34
3 Preparation for a dive with MB levels
V UWATEC Aladin TEC 2G
3.1 Setting the MB level
To change the MB level Aladin must be in user mode (time of day display).
1. Push or until the symbol for MB levels appears.
2.
Confirm that you wish to change the displayed MB level by
pushing .
3. Change MB level by pushing or .
4. Confirm the selected MB level with .
Without confirmation the display will disappear after 3 minutes and your entries
will not be accepted.
Aladin will display the symbol to confirm that an MB level beyond L0
(L1-L5) has been chosen. During the dive the MB level is shown by pressing 2x
. If however a level stop is ignored, the new MB level is shown (->35).
MB levels have an influence on the dive planner.
4 Functions during the dive with MB levels
4.1 Level stop information
MB no-stop time
While diving with MB levels L1 to L5 Aladin will display the MB no-stop time instead of the ordinary no-stop
time. Within the MB no-stop time no level stops are required.
"NO STOP" and the MB level symbol
are visible. The remaining MB no-stop time is shown in minutes.
• Information and alarms for MB no-stop time and ordinary no-
stop time are the same (->26).
• No-stop time relative to L0 is shown by pressing 3x
(see )
• Regardless of the MB level, we generally recommend to perform
a slow ascent during the last few metres / feet.
Level stop
On entering the level stop phase,
"NO STOP"
disappears and the arrow
arrow flashes for 8 seconds and an audible attention beep
goes off. To complete the dive without cascading to a lower MB level, all
requested level stops must be observed.
The deepest level stop is displayed in metres (feet). The display "2: 3m "
("2: 10ft") means that a level stop of 2 minutes at a depth of 3 metres (10 feet) has
to be observed. Deco information relative to L0 is shown on an alternate display
(see ).
When a level stop has been finished, the next higher level stop – if present
– is displayed. When all level stops have been observed, the arrow