Operating the Saphir compact air
conditioning unit with the TG 1000 sinus
power inverter
The ElektrikSet (Electrical kit – part no. 40090-23100) and
the KlimaSet (Air conditioning kit – part no. 40090-25900)
are required in order to make the electrical connection of the
power inverter (part no. 40090-81000). A connecting diagram
and a description of the connection are provided with the
respective set.
Operating modes of the TG 1000 sinus
power inverter with the Saphir compact air
conditioning unit
The power inverter is controlled by the air conditioning
electronics after the air conditioning unit has been
switched on. The air conditioning unit checks the status of the
power inverter and the connected electrical supply at short in-
tervals (D+ of alternator, starter battery / auxiliary battery and
national network).
If the Saphir compact air conditioning unit is operated
with the TG 1000 sinus power inverter, the following
operating statuses are possible:
Operating mode 1
via auxiliary battery with 12 V
(vehicle engine off, alternator D+ is 0 V).
Switch on the Saphir compact air conditioning unit via the
remote handset.
If the auxiliary battery voltage is higher than 12 V when
the unit is switched on, the Saphir compact air conditioning
unit is started.
Only FAN MODE with fan settings FAN LOW and
FAN HIGH can be used.
If the auxiliary battery voltage is lower than 12 V, the red
LED on the IR receiver illuminates. The air conditioning unit
does not start up. Reset by switching the air conditioning
unit off.
The air conditioning unit with power inverter cannot be
switched on again using the remote handset until the auxil-
iary battery has been recharged (above 12 V – no automatic
restart).
If the voltage of the auxiliary battery drops to less than
10.8 V while the air conditioning unit is being operated,
the air conditioning unit with power inverter is switched
off completely to prevent further battery discharging. No
red LED therefore illuminates on the IR receiver as a fault
indicator.
The air conditioning unit with power inverter cannot be
switched on again using the remote handset until the auxil-
iary battery has been recharged (above 12 V – no automatic
restart).
The air conditioning unit continues to run and the power
inverter switches itself off when the mains voltage is applied
(connection a – for national network input voltage, see
Operating mode 3”).
Operating mode 2
via alternator with 12 V
(vehicle engine running, alternator supplies D+ = 12 V)
The auxiliary battery and the starter battery are switched in
parallel via the isolating relay. The relay is actuated by D+ from
the alternator (or D+ substitute).
Switch on the Saphir compact air conditioning unit via the
remote handset.
If the auxiliary battery voltage is higher than 12 V when
the unit is switched on, the Saphir compact air conditioning
unit is started.
The full functionality of the air conditioning unit is
available.
If the air conditioning unit is operating and the engine is
switched off, the previous setting that was selected using
the remote handset is used when the vehicle is started
again. The switchover procedure is controlled by the
D+ signal.
Tip
To protect the batteries and limit the use of the alternator
charge current, switch electrical consumers off if possible
(e.g. switch refrigerator to gas operation).
When the engine is switched off the air conditioning unit
and the power inverter switch themselves off. The green
LED on the IR receiver flashes briefly.
If the starter battery voltage drops to less than 11.7 V
or the auxiliary battery voltage drops to less than
10.8 V during operation, the air conditioning unit with
power inverter switches off completely to prevent further
battery discharging. No red LED therefore illuminates on
the IR receiver as a fault indicator.
The air conditioning unit with power inverter cannot be
switched on again using the remote handset until the aux-
iliary / starter battery has been recharged (above 12 V – no
automatic restart).
The air conditioning unit and the power inverter switch them-
selves off when mains voltage is applied
(connection a – for
national network input voltage, see “Operating mode 3”). The
red LED on the IR receiver illuminates. The air conditioning
unit must be switched on again via the remote hand set.
Operating mode 3
via national network with 230 V ~
The 230 V ~ national network is looped through from connec-
tor (a) to connector (c) via a relay in the power inverter. The
power inverter remains switched off. The air conditioning unit
can now be operated at any cooling setting.
c
a
The air conditioning unit with power inverter switches itself off
in the following cases:
National network failure
National network input voltage connector (a) is disconnected
14

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Truma-Saphir-compact

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Truma Saphir compact bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Truma Saphir compact in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Deens als bijlage per email.

De handleiding is 1,67 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info