Functional dimension
To ensure that the Mover functions correctly, the clearance be-
tween the tyres and the swivelled driving rollers is 10 – 26 mm
(for loaded vehicles and loaded wheels).
If the clearance is
not within this range, steps must be taken to check whether
or not the correct tyre type is used (see “Identifying the angle
bracket”) or if the tyres are heavily worn. All tyres must have
the same inflation pressure as per the manufacturer’s instruc-
tions (check at regular intervals!).
10 – 26 mm
min. 110 mm
Driving direction
Fit covering plates
Place covering plate onto housing and fix in position with
3 guide pins in each case (knock in with a hammer or screw-
driver handle).
Installing the position indicator
Push the position indicator into the two holes in the gearbox.
Installation of motor cables and control unit
The Mover is only suitable for connection to 12 V batteries
(DC voltage)!
Remove battery cable terminals and disconnect any
external electrical power before starting work. If you are
unsure about the electrical installation, have it checked out by
a qualified Auto Electrician.
Two high-power cables for the drive motor (6 mm²) and a two-
wire cable for the swivel-in motor are pre-attached to each
motor. Mark the respective motor connecting cables (motor
A or B – see also wiring diagram) and temporarily route to the
intended control unit installation position on the underbody of
the caravan. An example of a suitable location for the control
unit is in a bed stowage box in close proximity to the manoeu-
vring system, at least 40 cm away from the battery.
Insert control unit into stowage box and secure with the sup-
plied chipboard screws (5 x 16).
Drill a 25 mm diameter hole on the floor of the caravan for
leading the cables through, approx. 150 mm from the control
unit terminal strip.
Take care to avoid any chassis members, gas pipes and
electrical wires!
Drill hole and lead cables through floor of caravan to control
unit in such a way that they cannot chafe (particularly when
leading through metal panels). This can be done using protec-
tive tubes, which will prevent the cables from being damaged.
The drive motors move during operation. To com-
pensate for this, the cables should be secured loosely
with a little play in this area in order to prevent cable stretching.
No cables must be routed over the control unit!
Secure cables to chassis and / or underbody using the sup-
plied clips and screws.
Seal hole in vehicle underbody using plastic body sealant.
Connecting diagram
(with conventional brake lights)
Top-down
view
Safety
socket
Pin 6
Pin 3
Swivel-in
motors
Drive
motor
Drive
motor
Battery
Installation
in front of
axle
Safety
contact
Fuse
A
3
6
8
1
2
97
5
4
11
10
1213
– + – +
+ –
– +
B
A
1234
+
-
B
A
B
Pin 6
Pin 3
r
r
+ –
Connecting the drive motors
Cut motor cable of drive motor that is furthest away from
control unit to length. Shorten the motor cable of the nearest
drive motor to the same length. The two drive motor cables
must be of the same length to ensure that the drive output of
the Mover is uniform! Excess cable must be routed in wavy
lines without looping.
Crimp the provided flat plugs onto the drive motor cables.
Release flap at control unit terminal strip by pressing and con-
nect cables as shown in wiring diagram (red = positive,
black = negative). Please ensure that the connections are
made properly!
Connecting the swivel-in motors
The positive connection (r) of the 2-wire motor connection
cables has been marked with a red longitudinal line along the
cable insulation.
Mark motor cables A + B and route to control unit (shorten
cables to same length if necessary).
Slide spade connector sleeve insulation over the cables
(e.g. black for motor A and transparent for motor B). Crimp on
spade connector sleeves, slide on spade connector sleeve
insulation and connect as shown in connecting diagram.
Connecting the battery
Route battery connecting cables (10 mm²) to control unit and
securely attach using the provided clips and screws.
The battery connecting cables must not be extended.
They must be routed separately from the motor cables,
and must not run over the control unit.
Route battery connecting cables so that they do not chafe
(particularly at leadthroughs through metal panels). Use suit-
able leadthrough grommets for protection in order to prevent
damage to cables. Connect battery connecting cables to the
existing battery terminals (red = positive, black = negative).
The connection to the control unit (as per the connecting dia-
gram) must take place in the order – nut, battery connection
ring, nut (torque 10 Nm ± 1).
19

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Truma-Mover-Mover-H-SE

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Truma Mover Mover H SE bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Truma Mover Mover H SE in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Deens als bijlage per email.

De handleiding is 7,52 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info