submerged clear water pump, near-ground suction TWP 4006 E / TWP 7506 E
Errors and faults
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the on-site fusing.
Check the power cable and mains plug for damages. If you
notice damages, do not try to take the device back into
operation. To avoid safety hazards, do not perform any
repairs. Dispose of the device as described in the Disposal
chapter.
Check whether the float switch is located above the
automatic switch-on position.
The device might have overheated and the thermal
protection circuit is activated.
If so, wait for approx. 10minutes before restarting the
device. If the device is not starting, have the electrics
checked by a specialist company or by Trotec.
The water temperature is above 35°C and the thermal
protection circuit is activated.
Check whether there are any foreign objects in the air
intake opening(6), the reducer(7) and/ or the hose or
pipe.
The device is running, but not pumping any water:
Check the inside of the device for any remaining air. Lower
the device into the water at a slight angle and wait for the
air to escape completely.
Switch the device off and on again several times while it is
in the water in order to support automatic ventilation.
Check whether the minimum water level has been
reached, see technical data. In order to start pumping, the
device requires a minimum water level.
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device.
Check whether the used hose diameter is too small.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
Check whether the reducer(7), the backflow preventer(8)
and/ or the elbow(10) are clogged.
The device is not switching off automatically:
The float switch is hindered from lowering. Check whether
the float switch can move freely. Remove any blockages or
ensure sufficient freedom of movement for the float
switch.
The device switches off after a brief runtime:
Check whether the water temperature is too high. The
device might have overheated due to a too high water
temperature and the thermal protection circuit is activated.
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device. The
device might have overheated due to the blockage and the
thermal protection circuit is activated.
Insufficient or decreasing conveying capacity:
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device.
Check the hose diameter and the delivery head. An
excessive delivery head paired with a small hose diameter
can cause a reduction of the conveying capacity.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
The connection system cannot be opened or closed:
Check the connection system for dirt and remove any dirt if
required, as described in the Cleaning chapter.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Trotec TWP7506E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Trotec TWP7506E in de taal/talen: Engels als bijlage per email.

De handleiding is 1,83 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Trotec TWP7506E

Trotec TWP7506E Gebruiksaanwijzing - Nederlands - 16 pagina's

Trotec TWP7506E Gebruiksaanwijzing - Deutsch - 16 pagina's

Trotec TWP7506E Gebruiksaanwijzing - Français - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info