B - 1 Operating manual dehumidifier TTR 5000
G
B - 2 Operating manual dehumidifier TTR 5000
G
Table of contents
01. Please read before putting into operation . . . . . . . . . . . . B - 1
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 1
02. Transport and installation . . . . . . . . . . . . . . . . . . . . . . . . B - 3
Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 3
Installation of the dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . B - 3
Recommended measures to be taken before starting up . . . . . . B - 4
03. Description of appliance . . . . . . . . . . . . . . . . . . . . . . . . . . B - 4
Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 4
04. Structure of the dehumidifier . . . . . . . . . . . . . . . . . . . . . . B - 5
Housing frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Rotor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Rotor bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Rotor sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Process and regeneration air filter. . . . . . . . . . . . . . . . . . . . . . . B - 5
Process air fan and regeneration air filter . . . . . . . . . . . . . . . . . B - 5
Regeneration air heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
Control cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 5
05. Operation with electric air heater . . . . . . . . . . . . . . . . . . B - 6
Switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
Switching off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
Function of the electric air heater . . . . . . . . . . . . . . . . . . . . . . . B - 6
06. Triggering of the safety devices and messages . . . . . . . B - 6
Motor faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
Thermostat faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
Electric heater faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 6
07. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 7
08. Care and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Rotor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Cleaning the rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Removing the rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Rotor bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Electric motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Air filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 8
Air heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 9
Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 9
Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 9
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 9
Maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B - 9
09. Damaging effects on silica gel rotors . . . . . . . . . . . . . . . B - 9
This publication replaces all previous versions. No part of this publication may be reproduced or processed, copied or
distributed via electronic means in any form whatsoever except with our written permission. We reserve the right to make
technical changes. All rights reserved. Trademarks are used in the following without any guarantee of their free usability
and are basically as the manufacturer describes them. The trademarks used are registered and should be treated as
such. We reserve the right to make design alterations in the interests of continuing product improvement and altera-
tions to the shape or colour. The package contents may differ from the product illustrations. This document has been
prepared with the appropriate care. Nevertheless, we can accept no liability for any errors or omissions. © TROTEC®
01. Please read before putting into operation
The TTR 5000 dehumidifier has been constructed according to the cur-
rent state of the art and fulfils the requirements of the applicable Eu-
ropean and national guidelines. This conformity has been certified; the
manufacturer is in possession of the relevant declarations and docu-
ments. You as a user must follow these operating instructions in order
to maintain this condition and to ensure safe operation!
• This operating manual is part of the appliance and must always be
kept in the immediate vicinity of the place of installation or of the
appliance.
Before using the appliance, this operating manual must be read care
fully and followed in all points.
Observe the applicable national regulations governing safety and the
prevention of accidents when using the appliance.
The appliance was subjected to extensive material, functional and
quality checks before delivery. This appliance can nevertheless re-
present a hazard if it is used improperly or inappropriately by persons
who have not been trained to operate it. Therefore please always
observe the following safety instructions.
Safety instructions
The appliance must not be used in rooms exposed to acetone, undilu-
ted acids or solvents.
The appliance must not be installed and used in rooms where there is
a risk of explosion.
The appliance must not be installed and used in atmospheres contai-
ning oil, petrol, sulphur, chlorine or salt.
The appliance must be installed in a stable, upright position for opera-
tion.
The appliance must not be exposed to a direct jet of water during
operation.
It must always be ensured that the air intake and outlet are not obs-
tructed.
The suction side must always be free of dirt and loose objects.
Never insert foreign bodies into the appliance.
The appliance must not be covered over or transported during opera-
tion.
All electrical cables external to the appliance must be protected
against being damaged (e.g. by animals).
Extensions to the connecting cable must be selected according to the
power rating of the appliance, the cable length and the purpose of
use.
Any use or operation other than that specified in this manual is not
permitted. Failure to observe this will cancel any liability on our part
and will result in the warranty becoming void.
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Trotec TTR 5000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Trotec TTR 5000 in de taal/talen: Duits, Engels, Frans, Turks als bijlage per email.

De handleiding is 3,16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info