726841
3
Verklein
Vergroot
Pagina terug
1/25
Pagina verder
TRT-BA-TTK29E/TTK51E/TTK70E-TC2019-33-002-EN
TTK 29 E / TTK 51 E / TTK 70 E
EN
OPERATING MANUAL
DEHUMIDIFIER
2 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................5
Transport and storage...........................................................6
Assembly and installation.....................................................7
Operation ...............................................................................8
Errors and faults..................................................................11
Maintenance ........................................................................13
Technical annex...................................................................17
Disposal ...............................................................................24
Notes regarding the operating manual
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to extremely flammable gas.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
TTK 29 E
https://hub.trotec.com/?id=39925
TTK 51 E
https://hub.trotec.com/?id=41803
TTK 70 E
https://hub.trotec.com/?id=41850
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it
when wet.
EN 3
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
The electrical connection must correspond to the
specifications in chapter Technical data.
Insert the mains plug into a properly secured mains
socket.
Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and
loose objects.
Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
Only transport the device in an upright position with an
emptied condensation tank or drain hose.
Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for dehumidifiers filled with R290
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
Only position the device in rooms where there is no
permanent source of ignition (e.g. open flames, an active
gas appliance or an electric heater).
Please note that the refrigerant is odourless.
Only install the device in compliance with the national
installation regulations.
Observe the national gas regulations.
Only install, operate and store the device TTK 29 E/ TTK
51 E / TTK 70 E in a room measuring more than 4m
2
.
Store the device in a way that no mechanical damage can
occur.
Please note that the connected ducts must not contain any
sources of ignition.
R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
Do not drill through or burn.
Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
4 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
living rooms, bedrooms, bathrooms and basements
laundries, holiday homes, camper vans, boats
maintaining the dryness of:
storage spaces, archives, laboratories, garages
bathrooms, wash rooms, changing rooms etc.
Improper use
The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
TTK 29 E / TTK 51 E / TTK 70 E
Follow the manual
This symbol indicates that the operating manual must
be observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.
EN 5
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Residual risks
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or if the tank is not installed correctly, the condensation
tank indicator light on the control panel will be illuminated and
an error code will be displayed as well (see chapter Operating
elements). The device switches off. The indications only
disappear once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to
approx. 35%.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.
6 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Device depiction
1
2
3
3
4
5
6
No. Designation
1 Control panel
2 Air outlet
3 Handle
4 Air inlet
5 Condensation drain hose connection
6 Condensation tank
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with a carry
handle.
Before transporting the device, observe the following:
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Do not use the power cable to drag the device.
Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
Hold onto the mains plug while pulling the power cable out
of the mains socket.
When the device is not being used, observe the following
storage conditions:
Only store the device in a room measuring more than 4m
2
.
dry and protected from frost and heat
in an upright position where it is protected from dust and
direct sunlight
with a cover to protect it from invasive dust, if necessary
Place no further devices or objects on top of the device to
prevent it from being damaged.
EN 7
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Assembly and installation
Scope of delivery
1x Device
1x Air filter
1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D
Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
Only position the device in rooms where there is no
permanent source of ignition (e.g. open flames, an active
gas appliance or an electric heater).
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
When positioning the device, keep a sufficient distance to
heat sources.
Make sure that no curtains or other objects interfere with
the air flow.
When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Make sure that the air filter is installed before switching
the device on.
8 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Opening the ventilation flaps
1. Prior to switching the device on, open the ventilation flaps
at the air outlet.
Inserting the condensation tank
Ensure that the float inside the condensation tank is
inserted correctly.
Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains
socket.
Operation
Notes:
Avoid open doors and windows.
After being switched on, the device operates fully
automatically.
The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
7
9
11
8
10
12
14
16
13
15
17
No. Designation Meaning
7 Segment display Indication of the current relative room
humidity level
Indication of the relative room humidity
level during set-up
Indication of the number of hours during
timer programming
Indication of the operating mode
8 DEFROST LED Illuminated when automatic defrosting
is in progress.
9 SETbutton For setting continuous operation(CO)
For setting the relative humidity level
(50% to 80%RH in increments of
10%)
For setting comfort mode(AU)
10 HILED High fan speed
11 SPEED button For setting a high or low fan speed
12 LOWLED Low fan speed
13 TIMER LED Illuminated when the timer is activated.
14 TIMER button Switches the timer function on or off.
15 POWER LED Illuminated during operation.
Flashes when automatic defrosting is in
progress.
16 ON/OFF button Power button:
For switching the device on or off
17 FULL LED Illuminated when the condensation tank
is full or not installed correctly.
EN 9
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the ON/OFFbutton(16).
ð The device starts in continuous operation.
ð The POWERLED(15) is illuminated.
Setting the operating mode
Dehumidification
Continuous operation
Comfort mode
Laundry drying function
Dehumidification
The device keeps running until reaching the desired relative
room humidity. Then the compressor switches off and the fan
keeps running. Once the desired relative room humidity is
exceeded, the compressor switches back on.
In this operating mode, the desired relative room humidity can
be set at any time in increments of 10% within a setting range
of 50% to 80%.
Setting the desired relative room humidity
You can only change the relative room humidity in
dehumidification mode.
1. Repeatedly press the SETbutton(9) to set the room's
relative humidity level. Setting is possible in the range
between 50% and 80% in increments of 10%.
ð The desired relative room humidity is indicated in the
segment display(7) for approx.5seconds. Then the
current relative room humidity is displayed again.
Setting the fan speed
Using this function you can choose between a low and a high
fan speed. The fan speed can only be adjusted in
dehumidification mode.
1. Press the SPEEDbutton(11) to select the desired fan
speed.
ð The corresponding LED will be illuminated– either
HI(10) or LOW(12).
Continuous operation
The device dehumidifies the air constantly and regardless of the
current humidity level. The desired relative room humidity
cannot be adjusted in this operating mode.
1. Repeatedly press the SETbutton(9) until CO is indicated
on the segment display(7).
ð Continuous operation is selected.
Info
For continuous operation the condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.
Comfort mode
Comfort mode ensures an agreeable humidity level ranging
between 50% and 60%. Depending on the room temperature
the device automatically regulates the convenient humidity level
choosing a value from 50% – 55% – 60%.
In this operating mode it is not possible to regulate the room's
relative humidity level manually.
1. Repeatedly press the SETbutton(9) until AU is indicated
on the segment display(7).
ð Comfort mode is selected.
Setting the timer
For the device to switch on or off automatically after a
predefined number of hours (max. 24hrs) you can programme
the timer.
The timer can be programmed in increments of 1hour (0to
24h).
The timer can be set in all operating modes.
You can activate the function regardless of the device being
switched on or off.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
ü The device is switched off.
1. Press the TIMER button(14) to programme automatic
switch-on.
ð The TIMERLED(13) is illuminated.
ð The segment display(7) indicates the number of hours
until automatic switch-on. Standard: 0.0
2. Repeatedly press the TIMERbutton(14) until the desired
number of hours until automatic switch-on has been set.
ð The number of hours is indicated on the segment
display(7) for approx.5s. Then the current relative
humidity level of the room will be indicated.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself on.
10 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Automatic switch-off
ü The device is switched on.
1. Press the TIMERbutton(14) to programme automatic
switch-off.
ð The TIMERLED(13) is illuminated.
ð The segment display(7) indicates the number of hours
until automatic switch-off. Standard: 0.0
2. Repeatedly press the TIMERbutton(14) to select the
number of hours until automatic switch-off.
ð The number of hours is indicated on the segment
display(7) for approx.5s. Then the current relative
humidity level of the room will be indicated.
3. The device keeps running until the given switch-off time
has expired or until the device is switched off manually.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself off.
Note
You can deactivate automatic switch-on and switch-off
by setting the respective number of hours back to 0 or
by manually switching the device on or off.
A full condensation tank can cause the device to be
switched off before the set number of hours until
automatic switch-off have elapsed.
Auto stop function
If the condensation tank is full or not inserted correctly, the
device will stop automatically.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.
ü A suitable hose (diameter= 1/2") is ready for use.
ü The device is switched off.
1. Take the condensation tank out of the device.
2. Push one end of the hose onto the hose connection.
3. Put the condensation tank back in.
4. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
EN 11
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
The DEFROST LED(8) is illuminated.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity
level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check the filling level of the condensation tank and empty
it if necessary. The FULLLED(17) must not light up.
Check the condensation tank for correct seating.
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check the air filter for dirt. If necessary, clean or replace
the air filter.
Check whether the device is running in comfort mode. In
this case, the compressor switches off automatically once
the relative room humidity is below 50%.
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.
12 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
The compressor does not start:
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check whether the device is running in comfort mode. In
this case, the compressor switches off automatically once
the relative room humidity is below 50%.
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed on the segment
display(7):
Error code Cause Remedy
E1 Short circuit at the
temperature sensor
and printed circuit
board.
Please contact the
customer service.
E2 Short circuit between
the copper tube of
the temperature
sensor and the
PCBwiring.
Please contact the
customer service.
EN 13
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Maintenance
Maintenance intervals
Maintenance and care interval before every
start-up
as needed at least every
2weeks
at least every
4weeks
at least every
6months
at least
annually
Check the air inlets and outlets for
dirt and foreign objects and clean if
necessary
X X
Clean the exterior
X X
Visually check the inside of the
device for dirt
X X
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
X X
Replace the air filter
X
Check for damage
X
Check the attachment screws
X X
Test run
X
Empty the condensation tank and/
or drain hose
X
Maintenance and care log
Device type: .............................................
Device number: ....................................
Maintenance and care interval
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Check air inlets and outlets for dirt
and foreign objects and clean if
necessary
Clean the exterior
Visually check the inside of the
device for dirt
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Empty the condensation tank and/
or drain hose
Comments
1. Date: ...................................
Signature: ................................
2. Date: ....................................
Signature: .................................
3. Date: ....................................
Signature: .................................
4. Date: ....................................
Signature: .................................
5. Date: ...................................
Signature: ................................
6. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
9. Date: ...................................
Signature: ................................
10. Date: ..................................
Signature: .................................
11. Date: ..................................
Signature: .................................
12. Date: ..................................
Signature: .................................
13. Date: .................................
Signature: ................................
14. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
14 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Refrigerant circuit
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
5. Put the air filter back in.
Cleaning the air filter
Note
Ensure that the air filters are neither worn nor
damaged. The corners and edges of the air filters must
not be deformed or rounded. Before reinserting the air
filters, make sure that they are undamaged and dry!
The air filters have to be cleaned as soon as they are dirty. This
is brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
1. Take the condensation tank out of the device.
EN 15
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
2. Remove the air filter from the device.
3. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
4. Allow the filter to dry completely. Do not insert a wet filter
into the device!
5. Reinsert the air filter into the device.
6. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank. In doing so, make sure
that the float is positioned correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
16 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Emptying the condensation tank
When the condensation tank is full or not inserted correctly, the
device stops dehumidification operation and switches itself off.
The FULLLED(17) is illuminated.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. Make sure not
to damage the float when inserting or removing the
condensation tank.
ð In doing so, make sure that the float is positioned
correctly.
ð In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
EN 17
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Technical annex
Technical data
Parameter Value
Model TTK29E TTK51E TTK70E
Dehumidifying capacity, max. 10 l/ 24h 16 l / 24h 20 l / 24h
Air flow rate 110 m
3
/h 126 m
3
/h 135 m
3
/h
Operating range (temperature) 5°C to 35°C 5°C to 35°C 5°C to 35°C
Pressure suction side 0.6MPa 0.6MPa 0.6MPa
Pressure outlet side 2.5MPa 2.5MPa 2.5MPa
Max. permissible pressure 4MPa 4MPa 4MPa
Mains connection 220–240V/ 50Hz 220–240V/ 50Hz 220–240V/ 50Hz
Max. power input 190W 340W 420W
Nominal current 0.83 A 1.9 A 1.8A
Refrigerant R-290 R-290 R-290
Amount of refrigerant 45 g 52 g 68g
GWP factor 3 3 3
CO
2
equivalent 0.000135t 0.000156t 0.000204t
Condensation tank capacity 2.3l 2.3l 2.3l
Sound pressure level (at a distance of 1m) 42 dB(A) 44 dB(A) 46dB(A)
Dimensions (lengthx widthx height) 220x 365x 490 mm 220x 365x 490 mm 220x 365x 490 mm
Minimum distance to walls and other objects
A: top:
B: rear:
C: side:
D: front:
50 cm
50 cm
50 cm
50 cm
50cm
50cm
50cm
50cm
50cm
50cm
50cm
50cm
Weight 11 kg 12kg 12.5kg
18 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Circuit diagram TTK29E
EN 19
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Circuit diagram TTK51E
20 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Circuit diagram TTK70E
EN 21
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Overview of spare parts TTK29E Note: The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
Spare parts list TTK29E
NO. SPARE PART NO. SPARE PART
1 Front panel 21 Microswitch
2 Blade 22 Back panel
3 Fan motor 23 Float
4 Air duct 24 Filter
5 Base 25 Water tank
6 Fender 26 Capillary
7 Main PCB 27 Strainer
8 Control box 28 Power cord
9 Condensor 29 Power cord Clip
10 Evaporator 30 High pressure tube
11 Left panel 31 Low pressure tube
12 Display PCB 32 Foam tube
13 Control Panel 33 Compressor
14 Top panel 34 Work tube
15 Control panel 35 Right panel
16 Connection plate 36 Axial fan motor bracket
17 Rear blade 37 Upper poly foam
18 Front blade 38 Down poly foam
19 Micro switch frame 39 Carton
20 Micro switch handle Temperature humidity head
22 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Overview of spare parts TTK51E Note: The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
Spare parts list TTK51E
NO. SPARE PART NO. SPARE PART
1 Upper poly foam 22 Silicone sheath
2 Control panel 23 Capacitor
3 Display PCB 24 Capacitor cover
4 Control panel 25 Magnetic induction switch
5 Front blade 26 Float holder
6 Back panel 27 Foam mold Float
7 Connection panel 28 High pressure tube
8 Top panel 29 Low pressure tube
9 Back panel 30 Strainer
10 Left panel 31 Capillary
11 Evaporator 32 Power cord clip
12 Motor 33 Work tube
13 Rear blower 34 Right panel
14 Motor bracket 35 Gift panel
15 Air-Duct poly foam 36 Down poly foam
16 Filter 37 Power cord
17 Water tank 38 Compressor
18 Condensor 39 Front panel
19 Electrical box base 40 Base
20 Main PCB 41 Dam-board
21 Electrical box
EN 23
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Overview of spare parts TTK70E Note: The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
Spare parts list TTK70E
NO. SPARE PART NO. SPARE PART
1 Front panel 22 Rear blade
2 Rear blower 23 Front blade
3 Motor 24 Back panel
4 Air-Duct poly foam 25 Filter
5 Micro switch baffle 26 Float
6 Micro switch 27 Water tank
7 Motor bracket 28 Capillary
8 Wheel 29 Strainer
9 Base 30 Evaporator
10 Nut 31 Condensor
11 Capacitor 32 Power cord
12 Capacitor 33 Power cord clip
13 Fender 34 High pressure tube
14 Main PCB 35 Low pressure tube
15 Control box 36 Foam tube
16 Left panel 37 Compressor
17 Display PCB 38 Work tube
18 Control panel 39 Right panel
19 Top panel 40 Upper poly foam
20 Control panel 41 Down poly foam
21 Connection panel 42 Carton
24 EN
dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
Have the refrigerant (propane) disposed of appropriately and
according to the national regulations by a company with the
relevant certification (European Waste Catalogue 160504).
Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Trotec TTK29E bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Trotec TTK29E in de taal/talen: Engels als bijlage per email.

De handleiding is 3,21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Trotec TTK29E

Trotec TTK29E Gebruiksaanwijzing - Nederlands - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Deutsch - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Français - 26 pagina's

Trotec TTK29E Gebruiksaanwijzing - Italiano - 26 pagina's

Trotec TTK29E Gebruiksaanwijzing - Português - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Espanõl - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Polski - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Türkiye - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Dansk - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Svenska - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Norsk - 25 pagina's

Trotec TTK29E Gebruiksaanwijzing - Suomi - 25 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info