497463
4
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
PRESET OPERATION
AUTO RESTART OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
QUIET
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.
For comfortable sleep, automatically control air ow and automatically turn
OFF.
Press
COMFORT
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
2°F (1°C)/hour for 2 hours (maximum 4°F (2°C) increase). For heating
operation, the set temperature will decrease.
COMFORT SLEEP OPERATION
18
To start the sleep timer (OFF timer) operation
Press
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
SLEEP TIMER OPERATION
Firstly, turn off the circuit breaker.
Filter Reset
FILTER lamp lights on; the lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when
needed.
No benzine, thinner, polishing powder or chemically-treated duster.
MAINTENANCE
20
19
QUIET OPERATION
17
16
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
2. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
• Do not operate ON timer and OFF timer.
Note: Default setting of auto restart operation is on.
15
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except air ow direction).
1. Select your preferred operation.
2. Press and hold
PRESET
for 3 seconds to memorize the setting.
The P mark displays.
3. Press
PRESET
: Operate the preset operation.
The unit does not operate.
Cooling or Heating is abnormally
low.
The power main switch is turned
off.
The circuit breaker is activated to
cut off the power supply.
Stoppage of electric current.
ON timer is set.
• The lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are
opened.
• The air inlet or outlet of the
outdoor unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or
DRY.
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
21
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode, the fan will
continue to run for other 30 minutes, then it will turn off automatically.
This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times within 30
seconds.
TROUBLESHOOTING (CHECK POINT)
22
TEMPORARY OPERATION
TIMER OPERATION
14
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
Setting the ON Timer Setting the OFF Timer
1
Press
ON
: Set the desired
ON timer.
Press
OFF
: Set the desired
OFF timer.
2
Press
SET
: Set the timer. Press
SET
: Set the timer.
3
Press
CLR
: Cancel the timer. Press
CLR
: Cancel the timer.
During the every day timer is activating, both arrows ( , ) are indicated.
Note:
Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
1
Press
ON
: Set the ON
timer.
3
Press
SET
.
2
Press
OFF
: Set the OFF
timer.
4
Press
SET
button during
the ( or ) mark ashing.
Set the timer when the air conditioner is operating.
13
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or
stop without using the remote control.
Operation mode is set on AUTOMATIC operation,
preset temperature is 77°F (25°C) and fan
operation is automatic speed.
COOLING / HEATING / FAN ONLY OPERATION
DRY OPERATION
10
For dehumidi cation, a moderate cooling performance is controlled
automatically.
1. Press
MODE
: Select Dry .
2. Press
TEMP
: Set the desired temperature.
9
1. Press
MODE
: Select Cool , Heat , or Fan only .
2. Press
TEMP
: Set the desired temperature.
Cooling: Min. 62°F (17°C), Heating: Max. 86°F (30°C), Fan Only:
No temperature indication
3. Press
FAN
: Select AUTO, LOW , LOW+ , MED ,
MED+ , or HIGH .
Hi-POWER OPERATION
ECO OPERATION
12
To automatically control room to save energy (except in DRY and FAN ONLY mode)
Press
ECO
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 2°F
(1°C)/hour for 2 hours (maximum 4°F (2°C) increase). For heating
operation the set temperature will decrease.
11
To automatically control room temperature and air ow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
Press
Hi-POWER
: Start and stop the operation.
1110650133-1-EN.indd 41110650133-1-EN.indd 4 1/4/10 3:50:59 PM1/4/10 3:50:59 PM
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Toshiba RAS-15LAV-UL bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Toshiba RAS-15LAV-UL in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 3,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info