557974
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
MAINE
VT
NH
MASS
NEW YORK
PENNSYLVANIA
OHIO
IND
ILLINOIS
KENTUCKY
VIRGINIA
NORTH CAROLINATENNESSEE
WEST
VIRGINIA
SOUTH
CAROLINA
GEORGIAALABAMA
MISS
FLORIDA
LOUISIANA
ARKANSAS
OKLAHOMA
MISSOURI
TEXAS
KANSAS
NEW MEXICO
MEXICO
ARIZONA
CALIFORNIA
NEVADA UTAH COLORADO
NEBRASKA
WYOMING
IDAHO
OREGON
SOUTH DAKOTA
IOWA
WISCONSIN
MICHIGAN
MINN
NORTH DAKOTA
MONTANA
WASHINGTON
RHODE ISLAND
CONNECTICUT
NEW JERSEY
MARYLAND
DELAWARE
ASTRONOMIC LATITUDE ZONES
ZONES DE LATITUDE
ZONAS ASTRONOMICAS (LATITUDES)
SUSA
CUSA
NUSA
ALAS
HAWI
PROGRAMMING INSTRUCTIONS
457Z
A DIVISION OF NSi INDUSTRIES, LLC
PLEASE READ ALL INSTRUCTIONS FIRST
ONE YEAR LIMITED WARRANTY: If this product
fails because of a manufacturing defect within
one year after purchase, we will, at our option,
either repair or replace it at no charge. Our
warranty does not cover damage caused by
accident, abuse or misuse. We assume no
further liability with respect to the sale or use
of this product. THIS WARRANTY IS IN LIEU
OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE WARRANTY OF
MERCHANTABILITY. We make no warranty with
respect to the fitness of any goods for the users
particular application. This warranty gives you
specific legal rights, and you also may have other
rights which vary from state to state.
It is our intent to provide accurate and current
specification information. However, in the interest
of product improvement, TORK may alter the
specifications or constructional details without
prior notice.
SET
MODE
ENTER
R
1.0 INSTALLATION INSTRUCTION
• Plug the timer into a 120VAC receptacle. If you charge battery
overnight, the unit can be removed and programmed without
AC power.
• Press the R (RESET) button by using an insulated tool.
• Press the ENTER to start the timer.
2.0 SET TIME AND DATE (CALD)
• Press the MODE button two times to display “CALD” flashing.
• Press the ENTER button to start current time setting mode.
• Using buttons change year, then press SET button.
• Continue to using and SET button to enter current month,
date, hour, minutes, and seconds.
• Press the ENTER button to save the current time setting and return
to clock mode.
3.0 SET SCHEDULE
• Press the MODE button to display “PROG” flashing.
• Press the ENTER button to display “PROG 1 ON”. This is the first
of 20 ON/OFF pairs. For first ON program, press SET. To go to other
programs, press .
3.1 SELECT DAYS
• All days are flashing. Use to choose a different set of days,
then press SET.
3.2 SET ON
• Use to choose:
a) “TIME” for a program with user set times
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press SET. If “TIME” selected: Use buttons to change
hour, then press SET button. Repeat for minutes.
3.3 SET OFF
• “PROG 1 OFF” is flashing on display. Press SET.
• All days are flashing. Use to choose a different set of
days, then press SET.
• Use to choose:
a) “TIME” for a program with user set times,
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press SET. If “TIME” selected: Use buttons to change
hour, then press SET button. Repeat for minutes. Press SET.
• Repeat steps for a total 20 ON and 20 OFF time settings.
• Press the ENTER button to finish programming set and return to
clock mode.
4.0 OPTIONAL SUNSET/SUNRISE TIME ZONES
• Press the MODE button three times to display “ZONE” flashing.
• Press the ENTER button to start Zone setting mode.
• Use the keys to display the correct zone.
---
NOTE: NUSA (Default) = North USA, CUSA = Center USA, SUSA = South
USA, ALAS = Alaska&Northern Canada, HAWI = Hawaii&Puerto Rico.
----
• Press the ENTER button to save the setting and return to clock
mode.
5.0 OPTIONAL SUNSET/SUNRISE OFFSET
---
NOTE: This mode displays calculated sunset/sunrise. You can change to
turn ON/OFF earlier or later with this mode.
---
• Press the MODE button four times to display “SUN± ” flashing.
• Press the ENTER button to start offset mode .
• Screen displays today’s SNUP (sun up) time flashing. Use or
to change default time.
• Press SET and screen displays today’s SNST (sunset) time flashing.
Use to change default time.
• Press ENTER to complete the setting and back to normal clock
mode.
6.0 OPTIONAL CHANGE DAYLIGHT SAVINGS TIME (DST)
---
NOTE: Skip this step for default daylight savings dates. Follow instructions
below only if you need to remove or change. MANU (Manual Mode) – no
DST change by timer. NEW mode - change dates to something other than
default dates.
----
• Press the MODE button five times to display “DST” flashing.
• Press the ENTER button to choose daylight savings times.
• Use the to choose daylight savings options.
a) The display shows “INIT”. For timer to follow current U.S. DST
dates, press ENTER.
b) The display shows “MANU”. For no DST adjustment, press ENTER.
c) The display shows “NEW”. For modified DST dates, consult
technical support phone line.
7.0 COUNTDOWN TIME SETTING
---
NOTE: Countdown mode will postpone the manual off for a preset period.
As an example, press button to turn off lights and timer will wait five
minutes before load is shut down. This will give you time to exit the room.
---
• Press the MODE button to display “PROG” flashing.
• Press the ENTER button to display “PROG 1 ON”.
• Press the once to bring the Countdown time setting.
• Press SET for the Countdown (dL) screen.
• Press to choose length of time.
• Press ENTER to complete the setting and back to normal clock
mode.
8.0 RANDOM ON/OFF TIME
• Pressed key SET & simultaneously to set the Random function.
Display shows “RND”.
• To Cancel Random function simply repeat above procedure. The
“RND” sign will disappear from display.
9.0 OVERRIDE BUTTON FUNCTIONS ( )
• Press one time to turn timer ON or OFF.
10.0 ACTIVATE COUNTDOWN
---
NOTE: To activate Countdown step 7 must be completed and the timer in
the ON position.
---
• Press
RATINGS
• 120V 15A, 1800W General Purpose
• 120V 15A, 1800W Resistive
• 120V, 960W Tungsten
• 120V 1/3 HP, TV-5
LI-846
FOR TECHNICAL SUPPORT: SOUTIEN TECHNIQUE : PARA COMUNICARSE CON EL SERVICIO TÉCNICO: techsupport@nsiindustries.com 877.230.7874
http://waterheatertimer.org/Tork-consumer-timers-and-manuals.html
__________________________________________________________________________
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Tork 457Z bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Tork 457Z in de taal/talen: Engels als bijlage per email.

De handleiding is 0,38 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info