403121
3
Verklein
Vergroot
Pagina terug
1/16
Pagina verder
BPM WRIST 1480
USER GUIDE
V 2.3
0197
HL_BPMArm1480 B3.book Page 1 Wednesday, December 23, 2009 12:05 PM
Distributor:
Topcom Europe NV,
Grauwmeer 17, 3001 Heverlee, Belgium,
Manufacturer
Health & Life Co., Ltd.
9F No.186, Jian Yi Road, Chung Ho City, Taipei, Taiwan
Represented in Europe by:
EMERGO EUROPE
Molenstraat 15, 2513 BH, The Hague, The Netherlands
TEL : +31-70-3458570 FAX : +31-70-3467299
EC
REP
This Blood Pressure Monitor complies with the EC Directives and bears the
CE Mark "CE 0197".
This blood pressure monitor als complies with mainly the following
standards, (including but not limited)
Safety standards
EN 60601-1 - Medical electrical equipment part 1:General requirements for
safety
EN 60601-1-2 - Medical electrical equipment part 1-2: Collateral standard:
Electromagnetic compatibility-Requirements and tests
Performance standards:
EN 1060-1 Non-invasive sphygmomanometers - General requirements
EN 1060-3 Non-invasive sphygmomanometers - Supplementary
requirements for electromechanical blood pressure measuring systems.
EN 1060-4 Non-invasive sphygmomanometers - Test procedures to
determine the overall system accuracy of automated non-invasive
sphygmomanometers.
The declaration of conformity can be found on:
UK The features described in this manual are published with
reservation to modifications.
HL_BPMArm1480 B3.book Page 2 Wednesday, December 23, 2009 12:05 PM
3 REV 1.1 - U8006182
ENGLISH
3
TOPCOM BPM ARM 1480
ENGLISH
1Introduction
Congratulations with your purchase of the Topcom BPM Arm 1480. This fully
automatic, wrist mounted blood pressure monitor is both easy to use and ideally
suited for daily measurements. The large display includes systolic, diastolic
and pulse, all clearly shown at the completion of each reading.
In addition, you can store up to 48 measurements ine the memory, ideal for
users who want to monitor and track their blood pressure on a regular basis.
The BPM Arm 1480 is compact and portable, making it ideal for home use and
travel.
2 Safety instructions
1. This product is for household use only. It is not intended as a substitute for
consultation with your doctor.
2. For users diagnosed with common arrhythmia (atrial or ventricular
premature beats or atrial fibrillation), diabetes, poor circulation of blood,
kidney problems, or for users suffered from stroke, or for unconscious
users, the device might not be suitable for use. Consult your doctor in case
of any doubt.
3. The unit should not be operated by children so to avoid hazardous
situations.
4. The unit contains high-precision assemblies. Therefore, avoid extreme
temperatures, humidity, and direct sunlight. Avoid dropping or strongly
shocking the main unit, and protect it from dust.
5. Leaky batteries can damage the unit. Remove the batteries when the unit
is not used for a long time.
6. Do not press the START key when the cuff is not placed around the arm.
7. Do not disassemble the main unit or cuff.
8. If the unit is stored in a cold place, allow it to acclimate at room
temperature before use.
9. Clean the blood pressure monitor body and the cuff carefully with a slightly
damp, soft cloth. Do not press. Do not bend the pre-formed cuff inside out.
Do not wash the cuff or use chemical cleaner on it. Never use thinner,
alcohol or petrol (gasoline) as cleaner.
Please read this manual carefully before use. For specific
information on your own blood pressure, contact your
physician. Put the user guide away in a safe place for future
reference.
HL_BPMArm1480 B3.book Page 3 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 4
TOPCOM TWINTALKER 3000
4
TOPCOM BPM ARM 1480
3 Helpfull tips
Here are a few helpful tips to help you obtain more accurate readings:
Do not measure your blood pressure immediately after consuming a large
meal. To obtain more accurate readings, please wait one hour before
measuring.
Do not smoke or drink alcohol before measuring your blood pressure.
You should not be physically tired or exhausted while taking a
measurement.
It is important that you relax during measurement. Try to take 15-minutes
rest before a reading.
Do not take measurements if you are under stress or under tension.
Take your blood pressure at normal body temperature. If you are feeling
cold or hot, wait a while before taking a measurement.
If the monitor is stored at very low temperature (near freezing), have it
placed at a warm location for at least one hour before using it.
Wait about 5 minutes before taking the next pressure measurement.
4 Disposal of the device
At the end of the product lifecycle, you should not throw this product
into the normal household garbage but bring the product to a
collection point for the recycling of electrical and electronic
equipments. The symbol on the product, user guide and/or box
indicate this.
Some of the product materials can be re-used if you bring them to a recycling
point. By re-using some parts or raw materials from used products you make
an important contribution to the protection of the environment. Please contact
your local authorities in case you need more information on the collection points
in your area.
To avoid inaccurate results caused by electromagnetic
interference between electrical and electronic equipments,
do not use the device near a cell phone or microwave oven.
HL_BPMArm1480 B3.book Page 4 Wednesday, December 23, 2009 12:05 PM
5 REV 1.1 - U8006182
ENGLISH
5
TOPCOM BPM ARM 1480
ENGLISH
5 Blood pressure
5.1 What is Blood Pressure?
Blood pressure is the pressure exerted on the artery tube while blood flows
through the arteries. The pressure measured when the heart contracts and
sends blood out of the heart is systolic (highest). The pressure measured when
the heart dilates with blood flowing back into the heart is called diastolic (lowest)
blood pressure.
5.2 Why Measure Your Blood Pressure?
Among the various health problems afflicting modern people, problems
associated with high blood pressure are by far the most common. High blood
pressure's dangerously strong correlation with cardiovascular diseases
and high morbidity has made measuring blood pressures a necessity of
identifying those at risk.
5.3 Blood Pressure Standard
The World Health Organization (WHO) and National High Blood Pressure
Education Program has developed a Blood pressure standard, according to
which areas of low and high-risk blood pressure are identified. This standard
however, is a general guideline as individual's blood pressure varies among
different people and different groups...etc.
It is important that you consult with your physician regularly. Your physician will
tell you your normal blood pressure range as well as the point at which you will
be considered at risk.
Systolic >= 160
Diastolic >= 100
Stage 2 Hypertension
Systolic
140 - 159
Diastolic
90 - 94
Stage 1 Hypertension
Systolic < 120
Diastolic < 80
Normal
Systolic (mmHg) ->
140
90
100
160
Diastolic (mmHg)
!
120
Prehypertension
Systolic 120 - 139
Diastolic 80 - 89
80
HL_BPMArm1480 B3.book Page 5 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 6
TOPCOM TWINTALKER 3000
6
TOPCOM BPM ARM 1480
5.4 Blood Pressure Fluctuation
Blood pressure fluctuates all the time!
You should not be worried if you encountered two or three measurements at
high levels. Blood pressure changes over the month and even throughout the
day depending on circumstances (state of mind, temperature, ...)
Ex. Fluctuation within the day for a Male, 35 years old.
6 Battery installation
Open the battery compartiment by pulling the cover away on the bottom of
the unit.
Insert 4 AA alkaline batteries. Follow the polarity as indicated in the
battery compartiment.
18u 24u12u6u
50
100
150
200
mmHg
Systolic
Diastolic
HL_BPMArm1480 B3.book Page 6 Wednesday, December 23, 2009 12:05 PM
7 REV 1.1 - U8006182
ENGLISH
7
TOPCOM BPM ARM 1480
ENGLISH
7 Buttons
8Display
1. LCD display
2. MEMORY button
3. START / STOP button
4. Wrist cuff
5. Air Plug
6. Air Jack
1. Systolic pressure
2. Diastolic pressure
3. Pulse rate
4. Pulse symbol
5. Memory number
6. Error indication
7. Battery Low indicator
8. Blood pressure unit
1
2
3
4
5
6
1
2
3
4
6
7
8
5
HL_BPMArm1480 B3.book Page 7 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 8
TOPCOM TWINTALKER 3000
8
TOPCOM BPM ARM 1480
9 Applying the cuff
1. Remove all watches, jewelry, etc.
prior to attaching the cuff. Clothing
sleeves should be rolled up.
2. Press your brachial artery by two
fingers approximately 2,5 cm above
the elbow on the inside of your left
arm to determine where your
strongest pulse is.
3. Slide the end of arm cuff furthest
from the tube through the metal ring
to a loop. The smooth cloth should
be on the inside of the cuff. The
Velcro will be on the outside of the
cuff.
4. Put the left arm through the cuff
loop. The bottom of the cuff should
be approx. 1,5 cm above the elbow.
The cuff should lie over the
brachialartery on the inside of the
arm.
5. Pull the cuff so that the top and
bottom edges are tightened around
your arm.
6. When the cuff is positioned properly,
press the Velcro firmly against the
pile side of the cuff. The metal ring
will not touch your skin.
7. Relax your entire body,especially
the area between your elbow and
fingers. Place your elbow on a table
so that the cuff is at the same level
as your heart. Avoid leaning back
while the measurementis being
taken.
FP
HL_BPMArm1480 B3.book Page 8 Wednesday, December 23, 2009 12:05 PM
9 REV 1.1 - U8006182
ENGLISH
9
TOPCOM BPM ARM 1480
ENGLISH
10 Measurement
10.1 Important
1. This monitor automatically switches off 1 minute after the last key
operation.
2. To interrupt the measurement, simply press any key. The cuff will deflate
immediately after a key is pressed.
3. During the measurement, do not talk or move your arm or hand muscles.
10.2 Procedure
1. Press the START/STOP button to
start measurement. All segments
will appear on the display. The cuff
will inflate to the level that is right for
you.
2. When the right level is reached, the
cuff will deflate.
3. When the measurement is
completed, systolic, diastolic and
pulse will be shown simultaneously
on the LCD screen. The result will
be saved automatically in the
memory system. Up to 48 results
can be saved. If the memory is full,
the oldest data will be erased
automatically.
When a mistake was detected
during measurement the Error
mark appears on the display
ERROR
HL_BPMArm1480 B3.book Page 9 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 10
TOPCOM TWINTALKER 3000
10
TOPCOM BPM ARM 1480
11 Memory
To recall stored blood pressure measurement
results from the memory:
Press the MEMORY button. The last
memorized result will be displayed.
Press the MEMORY button again to recall the
previous result...
HL_BPMArm1480 B3.book Page 10 Wednesday, December 23, 2009 12:05 PM
11 REV 1.1 - U8006182
ENGLISH
11
TOPCOM BPM ARM 1480
ENGLISH
12 Technical specifications
*Specifications are subject to change without notice.
Model
Power source
Measurement zone
Accuracy
Pressure sensor
Inflation
Deflation
Memory capacity
Auto-shut-off
Operation environment
Storage environment
Weight
Cuff Arm circumference
Limited patient
Classification
BPM Arm 1480
6V DC: 4 x AA - Alkaline batteries
Pressure: 0~300 mmHg
Pulse: 40~199 beats/minute
Pressure: ±3 mmHg
Pulse: within ±5% of reading
Semi-conductor
Automatic - Pump driven
Automatic Pressure release valve
48
1 minute after last key operation
+10°C~+40°C
85% RH max.
-20°C~+70°C
85% RH max.
265g (with batteries)
23~33 cm / 9~13 in
Over 18 years old
Internally powered equipment
Classification of type BF
•IPX0
Not suitable for use in presence of
flammable anaesthetic mixture with air or
with oxygen or nitrous oxide
Continuous operation with short-time loading
HL_BPMArm1480 B3.book Page 11 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 12
TOPCOM TWINTALKER 3000
12
TOPCOM BPM ARM 1480
13 Topcom Warranty
13.1 Warranty period
The Topcom units have a 24-month warranty period. The warranty period starts
on the day the new unit is purchased. Consumables or defects causing a
negligible effect on operation or value of the equipment are not covered.
The warranty has to be proven by presentation of the original purchase receipt,
on which the date of purchase and the unit-model are indicated.
13.2 Warranty handling
A faulty unit needs to be returned to a Topcom service centre including a valid
purchase note.
If the unit develops a fault during the warranty period, Topcom or its officially
appointed service centre will repair any defects caused by material or
manufacturing faults free of charge.
Topcom will at its discretion fulfil its warranty obligations by either repairing or
exchanging the faulty units or parts of the faulty units. In case of replacement,
colour and model can be different from the original purchased unit.
The initial purchase date shall determine the start of the warranty period. The
warranty period is not extended if the unit is exchanged or repaired by Topcom
or its appointed service centres.
13.3 Warranty exclusions
Damage or defects caused by incorrect treatment or operation and damage
resulting from use of non-original parts or accessories not recommended by
Topcom are not covered by the warranty.
The warranty does not cover damage caused by outside factors, such as
lightning, water and fire, nor any damage caused during transportation.
No warranty can be claimed if the serial number on the units has been changed,
removed or rendered illegible.
To ensure precise measurement reading, recalibration of the device is
recommended after 2 years from the date of purchase. Shipping plus
handling cost and recalibration service fee shall be charged accordingly.
(www.topcom.net)
HL_BPMArm1480 B3.book Page 12 Wednesday, December 23, 2009 12:05 PM
HL_BPMArm1480 B3.book Page 13 Wednesday, December 23, 2009 12:05 PM
TOPCOM TWINTALKER 3000 14
TOPCOM TWINTALKER 3000
TOPCOM BPM ARM 1480
HL_BPMArm1480 B3.book Page 14 Wednesday, December 23, 2009 12:05 PM
15 REV 1.1 - U8006182
ENGLISH
TOPCOM BPM ARM 1480
Appendix
Guidance and manufacturer’s declaration electromagnetic emissions
The device is intended for use in the electromagnetic environment specified below. The cu stomer or the user of the device
should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environ ment guidance
RF emissions
CISPR 11
Group 1 The device uses RF energy only for its internal
function. Therefore, its RF e missions are very
low and are not likely to cause any
interference in nearby electronic equipment.
RF emissions
CISPR 11
Class B The device is suitable for use in all
establishments, including domestic
establishments and those directly connected
to the public low-voltage power supply network
that supplies buildings used for domestic
purposes.
Harmonic emissions
IEC 61000-3-2
Not applicable
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Not applicable
Guidance and manufacturer’s declaration electromagnetic immunity
The device is intended for use in the electromagnetic environment specified below. The cu stomer or the user of the device
should assure that it is used in such an environment.
Immunity test IEC 60601
test level
Compliance level
Electromagnetic environment
guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
r6 kV contact
r8kVair
r6kVcontact
r8kVair
Floors should be wood, concrete or
ceramic tile. If floors are covered
with synthetic material, the relative
humidity should be at least 30 %.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3A/m 3A/m
Power frequency magnetic fields
should be at levels characteristic of
a typical location in a typical
commercial or hospital environment.
Guidance and manufacturer’s declaration electromagnetic immunity
The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device
should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance
level
Electromagnetic environment
guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3Vrms
150 kHz to 80 MHz
3V/m
80 MHz to 2,5 GHz
3Vrms
3V/m
Portable and mobile RF communications
equipment should be used no closer to any part
of the device, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.
Recommended separation distance
d=1,2
d=1,2
80 MHz to 800 MHz
d=1,2
800 MHz to 2,5 GHz
where P is the maximum output power rating of
the transmitter in watts (W) according to the
transmitter manufacturer and d is the
recommended separation distance in metres (m).
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3Vrms
150 kHz to 80 MHz
3V/m
80 MHz to 2,5 GHz
3Vrms
3V/m
Portable and mobile RF communications
equipment should be used no closer to any
part of the device, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
Recommended separation distance
d=1,2
d=1,2
80 MHz t o 800 MH z
d=1,2
800 MHz to 2,5 GHz
where P is the maximum output power rating of
the transmitter in watts (W) according to the
transmitter manufacturer and d is the
recommended separation distance in metres
(m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,
a
should be less than the compliance level in
each frequency range.
b
Interference may occur in the vicinity of
equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the device is used exceeds the
applicable RF compliance level above, the deivce should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary, such as reorienting or relocating the device.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between
portable and mobile RF communications equipment and the device
The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (transmitters) and the deivce as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d=1,2
80 MHz to 800 MHz
d=1,2
800 MHz to 2,5 GHz
d=2,3
0,01
0,12 0,12 0,23
0,1
0,38 0,38 0,73
1
1,2 1,2 2,3
10
3,8 3,8 7,3
100
12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
HL_BPMArm1480 B3.book Page 15 Wednesday, December 23, 2009 12:05 PM
visit our website
www.topcom.net
MB300041
HL_BPMArm1480 B3.book Page 16 Wednesday, December 23, 2009 12:05 PM
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Topcom bpm 1480 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Topcom bpm 1480 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,45 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info