• Do not allow product to come into contact with oil based foods (e.g. oil/ tomato based sauces) as staining will occur.
• Inspect the air tube before and after each use for condensation. Allow to air dry before next use.
• To clean the valve, rub gently between your fingers in warm soapy water – do not insert objects as damage could result.
• Routine maintenance includes cleaning. No other servicing is required.
ASSEMBLING THE ELECTRIC BREAST PUMP
1.Wash your hands thoroughly before handling the pump.
Wash and sterilise your breast pump before using. Follow instructions in section for CLEANING, STERILISING AND MAINTENANCE.
2.Make sure the silicone insert is securely attached. Clip lip over end of horn first, then push tube through funnel, ensuring lip is fully clipped over the
other side also.
3.Push horn onto the lower pump body as far as it will go.
4.Push diaphragm down into lower pump body as far as it will go and push diaphragm cap over the top as far as it will go until it is sealed.
5.Push upper pump body and lower pump body together. They will click into place.
6.Push valve onto lower pump body.
7.It is possible for the valve to seal closed during storage & cleaning. Before each use remember to clean & squeeze the valve to open.
8.Screw bottle onto lower pump body.
9.Connect air tube onto upper pump body and the air tube socket of the motor unit. This is on the RIGHT of the two sockets on the motor unit.
10. Plug the electric adaptor into the electric adaptor socket of the motor unit. This is on the LEFT.
11. Plug the electric adaptor into the mains power supply.
BATTERY OPERATION
1.To install batteries, disconnect the air tube and mains adaptor.
2.Push the clip of the battery compartment towards centre of motor unit whilst pulling upwards. Remove the cover.
3.Insert batteries as indicated inside the battery compartment and push the cover back into place until it snaps shut.
4.Batteries are to be inserted with the correct polarity. Ensure that the + and – ends of the batteries are positioned correctly.
Requires 4AA batteries (sold separately). DO NOT USE RECHARGEABLE BATTERIES. The use of rechargeable batteries could cause your breast pump to
malfunction and will void the warranty. Non-rechargeable batteries are not to be recharged. Different types of batteries or new and used batteries are
not to be mixed. Only batteries of the same or equivalent type as recommended are to be used. Exhausted batteries are to be removed from the breast
pump. Batteries should always be removed or replaced by an adult. Keep away from children. Remove batteries if the electric breast pump will not be
used for some time. Help the environment by disposing of your product responsibly. The wheelie bin symbols indicate the product and batteries must
not be disposed of in the domestic waste as they contain substances which can be damaging to the environment and health. Please use designated
collection points or recycling facilities when disposing of the item or batteries.
INFORMATION ON THE DISPOSAL FOR WASTE ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE)
This symbol on the products and accompanying documents means that used electrical and electronic products should not be mixed
with general household waste.
For proper disposal for treatment, recovery and recycling, please take these products to designated collection points where they will
be accepted on a free of charge basis. In some countries you may be able to return your products to your local retailer upon the
purchase of a new product. Disposing of this correctly will help you save valuable resources and prevent any possible effects on
human health and the environment, which could otherwise arise from inappropriate waste handling.
Please contact you local authority for further details of your nearest collection point for WEEE.
Penalties may be applicable for the incorrect disposal of this product in accordance with national legislation.
USING THE ELECTRIC BREAST PUMP
1.Ensure that the breast pump has been cleaned and sterilised. Wash your hands before touching the breast pump or your breasts and avoid
touching inside the breast pump or the storage pot. Find a comfortable chair where you can relax
2.Hold the pump in whichever hand is most comfortable.
3.Place the silicone insert of the horn over your breast, so that it creates a seal all the way round. IF AIR CAN GET IN THERE WILL BE LOW OR NO
SUCTION.
4.Press the on/off button to promote milk let-down. This let-down setting is a gentle rhythm to get your milk flowing.
5.IMPORTANT: Sit upright and do not tilt the bottle while pumping, it should be kept upright at all times to avoid milk flowing back up through the air
tube. If this happens you must turn the breast pump off immediately as it could damage the motor. Read HELPFUL ADVICE for further information
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw Tommee Tippee Electric breast pump - 42301872 bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van Tommee Tippee Electric breast pump - 42301872 in de taal/talen: Engels als bijlage per email.
De handleiding is 0,3 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Stel vragen via chat aan uw handleiding
Stel uw vraag over deze PDF
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.