ANDORRA, ANDORRA Exclusive
2
In rooms with tight windows and doors (e.g. as energy-saving measure) fresh air intake may be low and thus affect draught of the
heater. Also your well-being may be affected; even your safety may be threatened. It may sometimes be necessary to assure
adequate intake of fresh air e.g. by installing air shutter close to heater or by combustion air pipe leading to exterior or to a well
aerated room (except boiler room). In particular it is vital that combustion air pipes are open during operation of fireplace. Steam
flues located in the same room with fireplace may affect heater’s operation (smoke may leak to inhabited room despite closed
fireplace door) and therefore must never be operated parallelly with the heater.
The outdoor combustion air could be supplied to the heater through the connecting socket which can be mounted on the bottom of
the backside of the heater.
10. Fire Protection
Distance from flammable structures and furniture
To assure adequate heat protection, a minimum distance of 20 cm in the back and 45 cm on the sides is required between the
heater and flammable structures and furniture.
Fire protection within radiation perimeter
Make sure that no flammable structures or furniture are within radiation perimeter of glass door, which is 80 cm. The distance may
be reduced to 40 cm if safety shade is installed between fireplace and flammable structures leaving enough space on both sides.
Fire protection outside radiation perimeter
Minimum distances from flammable structures and furniture are stated on heater’s label and must be observed.
Heater
For solid fuel heaters floor in front of fireplace’s door made of flammable materials must be protected by a non-flammable hearth.
Its minimum dimensions are 50 cm in the front and 30 cm on the sides of fireplace door.
11. Spare Parts
Only spare parts approved or provided by the manufacturer may be used. For inquiries, please, contact a specialized vendor.
No modifications to heater are allowed!
12. Warning in case of fire in chimney
Deposit in chimney may catch fire if unsuitable or humid fuel is used. In such case close all heater air holes immediately and call
the fire brigade. After fire is extinguished chimney should be inspected by an expert for cracks or untight places.
13. Nominal heating capacity, combustion air adjustment, and fuel burning time
Nominal heating capacity of heater is 7.5 kW and it is obtained at minimum supply pressure of 12 Pa.
When burning wood, set the slider (pull out to 7 mm) so that the primary combustion air intake is completely closed and
the secondary combustion air intake is fully open.
When burning lignite briquettes set the slider (pull out completely) so that both primary and secondary air intakes are fully open.
The combustion air slider is below the firing door.
Quantity and adjustment of combustion air for moderate operation:
14. Space Heating Capacity
For rooms with insulation non-conform with calorific insulation regulations space heating capacity should be determined pursuant to
DIN 18 893 for nominal heating capacity of 7.5 kW:
- in favourable heating conditions - 180 m
3
- in poor heating conditions - 145 m
3
- in unfavourable heating conditions - 98 m
3
For occasional heating – interrupted for more than 8 hours – space heating capacity is reduced by 25%.
15. Technical Data
Capacity: 7,5 kW
Weight: ANDORRA, ANDORRA II = 94 kg, ANDORRA Exclusive, ANDORRA II Exclusive = 101 kg,
ANDORRA ceramic = 117 kg, ANDORRA Soapstone = 197 kg, ANDORRA Special ceramic = 133 kg
Weight of fireproof concrete stones: lateral = 5 kg
Upper flue gas outlet: 150 mm