600941
3
Verklein
Vergroot
Pagina terug
1/37
Pagina verder
3
2. General use
The construction of THERM-EL electric boilers is designed for hot-water heating systems with induced
water circulation. They can be installed in central or individual-storey heating with induced circulation sealed or
open systems and they are characterized by an environmentally friendly operation without requirements for
venting of the combustion product. Service-free operation enables the installation of an external regulator, other
external regulating or controlling components (not included in the boiler delivery package!), simple equitherm
regulator or room thermostat integrated directly in the automatic controlling system which maintains the pre-set
room temperature. The electric boiler can be used as a universal source of heat for heating flats, small family
houses, resort houses and also as an alternative source to another main heat source of heating and hot water
preparation (also for transitional periods) for heat pumps, accumulation systems or in previously installed
central or single-storey heating systems etc. To attain higher output levels, boilers can be connected into a
cascade format.
3. General characteristics of THERM – EL electric boilers
Therm-EL electric boilers are wall-mounted appliances designed for water heating in a heating system and
potentially for domestic hot water heating (hereinafter referred to as “DHW”) in an indirect heating storage
tank.
THERM-EL electric boilers are manufactured in three performance versions in the lower output category:
8, 15 and 23 kW. The higher output series offers the following three types: 30, 38 and 45 kW. Structural
design as well as controlling system of these boilers are almost identical to the lower output series.
The electric boiler is formed by a steel vessel with inbuilt heating bars, heating temperature probe and safety
thermostat (these components are all located under one cover in the upper part of the vessel). The vessel is made
from a varnished steel sheet and it is fitted with thermal insulation. Heating water inlet, on which a circular
pump is mounted, is welded at the bottom part of the boiler. A lug located in the upper part of the vessel is
adjusted to the cup for the boiler temperature sensor and emergency thermostat. Heating water outlet and
threaded sleeve pieces are also located in the upper part of the vessel. Heating bars (up to 6) are screwed in the
sleeve pieces. Total output of each heating bar is 7.5 kW (there are three separate heating bodies with the output
of 2.5 kW in each heat bar). An automatic vent valve is placed at the highest point of the water heating circuit.
The boiler control box enables connection of an external room thermostat, addition of interface for the boiler
cascade connection type, programmable (time) switch and MRC (mass remote control) tariff switch.
Switching and electric line protection of the boiler and output inlets for the heating bars are not
located in the boiler but they always form part of the electric distributor of the flat or house. Terminals of the
main wiring are concentrated in the right part of the boiler. A sufficiently rated output line contactor or switch
(correctly marked!) which are used for disconnecting the electric boiler from the power network must be
connected right next to the boiler during its installation.
Boiler operation characteristics:
Operational stage of the boiler is launched when heating system temperature drops below the temperature
set on the boiler control panel or on the room thermostat. Control circuit of the heating bars becomes activated
and heating water inside the boiler body becomes heated gradually. After the required temperature has been
reached in the room (if a room thermostat is applied), the control microprocessor unit starts switching off the
heating bodies one by one and the heating of the water stops. At this moment the function of an adjustable
limited pump deceleration (in terms of time or temperature) becomes activated.
As standard, Therm-EL boilers are also fitted with emergency thermostat which delivers maximum safety.
It is connected to the control circuit of the integrated output contactor. The disconnection of the emergency
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Thermona THERM EL 45 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Thermona THERM EL 45 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,87 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info