11. PLACING THE UNIT (first read “General instructions”)
Please note: Before placing the unit, we recommend you first read Chapter 7
“Concentric flue system” on page 14.
11.1 Connection to the gas pipes (see page 28 for details)
You can determine where the gas pipes will be placed, dependent on the layout. Ensure control equipment is not
twisted during installation and there is no excessive tension. Accessibility of various connection points in relation
to components need to be maintained. After installation, check the connections for tightness in relation to gas. Use
a 1/2“ gas tap with connection. Ensure the gas pipes are dirt-free and sand-free, and gas and combustion
products from various parts and functioning is correct. The gas connection should only be undertaken when
the electricity supply is disconnected. This prevents any damage occurring to the gas control equipment.
11.2 Preparation and installation of the unit
Remove the packaging and check the unit for possible damage.
Please note: place the unit on a stable surface.
Do not place the unit on its back or on its side!
Place the unit at the installation location
One side window should now be removed in order to take the additional parts out of the unit.
Remove the decorative frames on the bottom, and rear respectively of the relevant window and loosen the set
screw on the front and 1side.
Remove the glass strip gently from his seat possibly with a screwdriver.
See example on Page.37 Figure I and J
With the supplied suction cup you can remove the windows easily. Take hold of the front window by its
sides and move it CAREFULLY upwards, then CAREFULLY and slowly pull the bottom of the window
towards you. Next, lower the window and leave it in a safe place where it cannot be broken or damaged.
Please note: the window is very fragile. You should therefore be very careful when (re)installing the
window. See example on Page.37 Figure K
Next, take the packaged components out of the unit and check to make sure they are not damaged or broken.
Situate the unit (see page 36 figures F, G and H as an example of an installation location) in your chosen
installation location . The device must be attached directly to the rear wall (mounting material not included).
Install the supplied convection grilles at least 50 cm below the ceiling on the appropriate wall. A lowered
ceiling inside the whole structure could be a possible solution in the event of a situation with a visual
obstruction.
The legs (page 37, figure L) of the unit can be adjusted, and if necessary shortened, see also dimensional
drawing on page 35. The adjustable feet allow fine adjustments (levelling) to be made.
You must keep aware with the installation and the height of the gas cartridge frame.
11.3 Installing gas control GV60 (see page 37 and 38 figures M to T)
Gas pipe, thermocouple and ignition cables have been placed in coils under the unit. The gas valve
including the burner control must be fitted by the installer in the gas cartridge.
The following step by step procedure:
1. After the windows are taken away and parts inside the gas fire are taken out; place the complete gas fire
carefully on the backside. You can use the wooden pallet to support the gas fire.
2. Cut the binders and CAREFULLY unroll the various lines and cables to the position where the gas control
cassette is to be placed. (see page 37 figure I )
3. Remove the screw holding gas valve bracket ( see page 38 figure O ) and carefully take away the gas valve
and move it to the side of the gas fire where you want to install the gas cassette.
4. Guide all tubes carefully so that sharp bending is prevented.
5. Position the gas valve on the correct position on the backside of the gas cassette.
(see page 38 figure P and Q )
6. Mount the gas valve including bracket inside the gas cassette, fix it with the 2 winged nuts inside. Slide the
burner control in the bracket. (see page 38 figure S )
7. Position the complete gas cassette in the surrounding construction of the gas fire. Be aware of the
maximum distance between gas fire and gas cassette limited by the length of thermocouple etc.
8. Make sure that the tubes, ignition cable and thermocouple are mounted without tensile stress and sharpness
9. After connecting the main gas supply, flue liner and before starting the build-up of the construction around
the gas fire: check all gas connections on leakage and make a test run to determine the proper functioning of
the gas fire installation.
26

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Thermocet Trimline 85 R - 1050 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Thermocet Trimline 85 R - 1050 in de taal/talen: Engels als bijlage per email.

De handleiding is 4,38 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Thermocet Trimline 85 R - 1050

Thermocet Trimline 85 R - 1050 Gebruiksaanwijzing en installatiehandleiding - Nederlands - 43 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info