6. INSTALLATION INSTRUCTIONS
Important
The installation may only be performed
by an authorized person
General instructions
∗ The gas fireplace must be installed, connected and inspected as a closed unit by a qualified fitter, according
to national, regional, and local standards and regulations.
∗ The flue tube system and the outlets in the outer wall or roof face must also meet the requirements outlined
in the applicable standards and regulations.
∗ The temperature of the walls and shelves near the side and back of the unit may not be more than 80°C
higher than the temperature of the environment.
∗ The unit has been approved in combination with the Metaloterm US system number: 0063-CPD-6308 con-
centric flue system Ø100 mm - Ø150 mm, in accordance with European CE standards for gas units, and
may therefore only be applied with this system.
∗ The unit needs to be inspected by the fitter for local gas distribution (gas type and gas pressure) as indicated
on the identification plate.
∗ The instructions are only applicable if the relevant country code is stated on the unit. If this is not the case,
the gas technical information for the relevant country needs to be consulted and modifications discussed
with the manufacturer.
∗ There will be air in the gas pipes when the unit is first used. The gas pipes therefore need to be vented first.
∗ Ignite the heater according to operating instructions and check whether the burner flame is uniform. After
the unit has been used for the first time, you should remove any deposits resulting from convection-curing
of the unit, from the glass window using a glass cleaner for heaters.
Warning:
Never install the unit against or within a flammable wall!
Distance to flammable materials:
∗ With respect to the front, side and top of the unit, a distance of 1000 mm needs to be kept between the unit
and: curtains, floor covering, upholstery and fabrics, and/or other flammable material unless stated other-
wise in these instructions.
Distance to non-flammable materials:
∗ The unit needs to be placed a minimum distance of 50 mm from the wall unless stated otherwise in these
instructions.
Important
∗ Construction material for fireplaces and mantles etc., or for an assembly must be made of non-flammable
material. This also applies to floors and ceilings. Never use flammable materials near the unit in compli-
ance with the abovementioned instructions.
Note: Please contact your supplier if you are unsure.