77..00 CCoonnnneeccttiinngg tthhee cceennttrraall ffuunnccttiioonnss
CCoonnnneeccttiinngg tthhee pprreesseennccee ssiimmuullaattiioonn sswwiittcchh
Use only a switch (possibly with control light) to connect and activate the
presence simulation function.
The connected central key at terminals , or acts on
all output contacts that can be activated individually.
88..00 CCoonnnneeccttiinngg tteerrmmiinnaallss ffoorr FFII sswwiittcchh
(RCD)
AApppplliiccaattiioonn::
in wet rooms, e.g. a bathroom
CCaauuttiioonn!!
Connect the F1 switch (RCD) only
at terminals I 4 (L).
The terminal I 4 (N) must be con-
nected with or without FI (RCD)!
66..00 UUnniivveerrssaall vvoollttaaggee ccoonnnneeccttiioonn
AApppplliiccaattiioonn oonnllyy wwiitthh LLUUXXOORR 440000::
EExxaammppllee::
Key control
UU
(acts on
CC11
) from a door intercom system
PPeerrmmiitttteedd ccoonnttrrooll vvoollttaaggee::
8 V AC/ DC to 48 V AC/ DC
CCoonnnneeccttiioonn::
Connect the control cable only to terminals
UU
.
55..00 CCoonnnneeccttiioonn aanndd iinnssttaallllaattiioonn
AA..CCoonnnneeccttiinngg tthhee iinnppuuttss
Input I 1/
UU
acts on contact
CC11
(
UU
only with LUXOR 400).
Input I 2 acts on contact
CC22
.
Input I 3 acts on contact
CC33
(LUXOR 400, 404).
Input I 4 acts on contact
CC44
(LUXOR 400, 404).
IImmppoorrttaanntt::
Use keys with a total glow lamp load of < 30 mA only at input
I 1! (with LUXOR 400, 404)
BB.. CCoonnnneeccttiinngg tthhee ttiimmee
ffuunnccttiioonnss ((ppeerrmmiitttteedd ffoorr kkeeyyss oonnllyy))::
Select connection I 1/
CC11
or I 2/
CC22
.
IInnffoo ttoo cchhaannnneell CC11::
Secondary switching time with switch off pre-warning (1 to 15 mins.) or swit-
ching channel (LUXOR 400, 404). Controlled time with switch off pre-warning
(1 to 20 mins.) or switching channel (LUXOR 402).
IInnffoo ttoo cchhaannnneell CC22::
Controlled time with switch off pre-warning (1 to 20 mins.) or switching
channel.
All other device channels are switching channels that can be controlled either
by switch or key at inputs I 3 and I
4.
CC.. CCoonnnneeccttiioonn iinn rroooomm wwiitthh FFII sswwiittcchh ((RRCCDD)) ((wwiitthh LLUUXXOORR 440000,, 440044))::
For using a FI switch in a room (e.g. bathroom), see the Figure in Section 8.
HHaallll
LLiivviinngg aarreeaa
CChhiilldd 11
KKiittcchheenn
CChhiilldd 22
PPaarreennttss
fflloooorr
(Keys)
Panic
(Keys)
Central
OONN
Diode module
(Keys)
Central
OOFFFF
(Switch)
Presence simu-
lation
mmaaxx.. 3300 mmAA