7.1 Starting up the generating set
Before the first start-up check the oil level.
Set the start-up switch (fig. 24 ref. 1) to ON
position. The word “WAIT” will appear on the
display for 8 seconds. When these have run out,
the electronic control panel will start the first
automatic procedure for starting up the
generating set. If the engine starts up at the end
of this phase, then the “generator running”
indicator
(fig. 24 ref. 6) will start to flash.
Should the engine not start up, this automatic
procedure will be repeated up to 4 times. If the
engine has not started up yet at the end of this
complete cycle, the “start-up failed” indicator
( fig.
24 ref. 5) will light up to signify that the
generating set has failed to start up.
If only the “start-up failed” indicator
(fig. 24 ref. 5)
stays lit, you can repeat the start-up procedure
several times.
If the generating set has not started up at all
even after many attempts, you will have to get in
touch with the After-sales service.
7.2 Turning the generating set off
To stop the generating set, set the "ON/OFF”
switch to "OFF" position (fig. 24 ref. 1).
Always turn the
generating set off after disconnecting the load
7.3 Control and alarm functions (Fig. 24)
2 Display unit: when the generating set has
started up, the total running hours will be
displayed. Press the button (fig. 12 ref. 9) to
display the partial running hours of the
generating set since the latest engine oil change.
3 High temperature indicator: this pilot lamp
will light up when the temperature of the
generating set goes over its safety value; the
engine will stop.
4 Minimum engine oil level indicator: this pilot
lamp will light up to indicate that the oil in the
engine has gone below the minimum level; the
engine will stop.
5 Engine start-up failed indicator: this pilot
lamp will light up to indicate that the generating
set has not started up, after all four attempts at
starting up have failed.
7 Engine oil change indicator: this pilot lamp
will light up when the engine has reached 100
running hours since the latest oil change. Upon
every engine oil change the After-sales service
staff must reset the Timer to make it restart from
zero.
8 Fuel reserve indicator: this pilot lamp will light
up when the fuel level has gone below its reserve
level (about 4 litres) inside the extra tank.
9 Display changeover switch: press this button
to display the running hours elapsed after the last
change of the engine oil.
10 Reset: this key (not visible) is used to reset
the panel (operation to be done only if the panel
has inexplicable behavior or the display shows
characters without any logic).
7.3.1 Control panel alarm causes and
resetting
During generating set use, alarm signals may be
displayed referring to engine oil checks. After
checking the engine oil, the control panel must
be reset in the following way:
Alarm: the red ‘service’ light is flashing.
Cause: 50 hours have elapsed since the latest
engine oil change and oil level should be
checked.
How to reset the alarm: with panel turned off,
press the partial counter key (Fig.30 Ref.9) and
while holding it down, turn the panel on and
release the push-button when the unit has
started up
Alarm: the red ‘service’ light is lit.
Cause: 100 hours have elapsed since the latest
engine oil change and engine oil should be
changed.
How to reset the alarm: turn on the panel and
wait for the generating set to start. Now press the
button hidden under the small hole in the bottom
left corner (Fig.30 Ref.10) and release it
immediately thereafter.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Telair Energy 2510D bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Telair Energy 2510D in de taal/talen: Engels als bijlage per email.

De handleiding is 3,16 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info