6
TECHNICAL INFORMATION FOR
INSTALLATION PERSONNEL
This appliance shall be installed only by
authorised persons and in accordance with the
manufacturer's installation instructions, local
gas fitting regulations, municipal building
codes, electrical wiring regulations, AS 5601 -
Gas Installations and any other statutory
regulations.
The wall and bench surfaces must be capable of
sustaining temperatures of 75 degrees Celsius.
All laminates, fixing adhesive and surfacing
materials should be certified suitable for this
temperature.
Any adjoining wall surface situated within 200mm
from the edge of any hob burner must be a suitable
non-combustible material for a height of 150mm for
the entire length of the hob. Any combustible
construction above the hotplate must be at least
600mm above the top of the burner and no
construction shall be within 450mm above the top of
the burner. A minimum depth of 60mm from the top
of the worktop surface must be provided for the
appliance.
3) INSTALLING THE HOT PLATE
Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In
case of doubt, do not use the appliance and contact
qualified personnel.
Never leave the packacing materials (cardboard,
bags, polystyrene foam, nails, etc.) within
children’s reach since they could become
potential sources of danger.
The measurements of the opening made in the top
of the modular cabinet and into which the hot plate
will be installed are indicated in fig. 7.
Always comply with the measurements given for the
hole into wich the appliance will be recessed (see
fig. 7 and 7/A).
The appliance belongs to class 3 and is
therefore subject to all the provisions
established by the provisions governing such
appliances.
INSTALLATION
COMPLY WITH THE DIMENSIONS
Overall Dimensions 4F: 580 x 500 mm
FIG. 7 FIG. 7/A
A B C D E
4F (580) 553 473 63.5 63.5 100 min.