12
CONVERSIONS
BURNER ARRANGEMENT ON THE HOT PLATE
10) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by
installing injectors suited to the type of gas required. To
do this, first remove the burner tops using a wrench “B”.
Now unscrew injector “A” (see fig. 13) and fit a injector
corresponding to the type of gas required.
It is advisable to tighten the injector in place.
After the injectors have been replaced, the burners
must be regulated as explained in paragraphs 9. The
technician must reset any seals on the regulating or
pre-regulating devices and affix the label
corresponding to the new gas regulation on the
appliance instead of the already existing one. This
label is supplied in the packet containing the spare
injectors.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorized Customer Care Department.
For the sake of convenience, the nominal rate chart also
lists the heat inputs of the burners, the diameter of the
injectors and the working pressures of the various types
of gas.
TABLE
BURNERS GAS WORKING
PRESSURE
mmH2O
HEAT
CAPACITY NOZZLE
DIAMETER
1/100 mm
HEAT
CAPACITY (W)
No.
DESCRIPTION
g/h l/h Min. Max.
1
TRIPLE RING
LPG
NATURAL 280
150 364 476 112
185 H3 1800
1800 5000
5000
2
RAPID
LPG
NATURAL 280
150 218 286 85
126 Y 800
800 3000
3000
4
AUXILIARY
LPG
NATURAL 280
150 73 95 50
80 450
450 1000
1000
FIG. 13