559304
5
Verklein
Vergroot
Pagina terug
1/44
Pagina verder
5
PROGRAM 1 - STANDARD
VERY FLAT NEGLECTED BATTERIES: If the battery is deeply discharged (and possibly sulfated), remove from the
vehicle and inspect the battery before connecting the charger for a recovery attempt.
The charger’s TURBO recovery mode cannot engage if it senses that the battery is still connected to a vehicle wiring circuit
which effectively offers a lower electrical resistance than the battery on its own. However, if the deep-discharged battery is not
removed for recovery, neither battery nor vehicle electronics will be damaged. Pay particularly close attention to the following
which is especially important for relatively small batteries such as those used on motorcycles, lawn tractors, jet-ski’s,
snowmobiles and similar: A battery left deep-discharged for an extended period may develop permanent damage in one or more
cells. Such batteries may heat up excessively during high current charging.
Monitor the battery temperature during the first hour, then hourly there-after. Check for unusual signs, such as bubbling or leaking
electrolyte, heightened activity in one cell compared to others, or hissing sounds. If at any time the battery is uncomfortably hot to
touch or you notice any unusual signs, DISCONNECT THE CHARGER IMMEDIATELY.
PRE-QUALIFICATION TEST: LEDs #5 / 6 / 7
TEST LEDs #5/6/7 indicate the condition of the battery prior to charging. Charging commences after 10 seconds.
Consult the “EARLY WARNING OF BATTERY PROBLEMS” table on page 2 (illustration 2) for TEST LED indications.
LED #7 (red) flashing: OptiMate 4 is injecting a test signal to see if the battery is recoverable. Once the indication becomes
steady for up to 10 seconds charging will commence. If flashing continues the battery cannot be successfully recovered.
RECOVERY / DESULFATE: LED #3
This mode engages if during pre-qualification LED #7 (red) or LED #6 (yellow) or both indicated. The program will
determine the correct charge mode. Charge time: Minimum 15 minutes, maximum 2 hours.
STANDARD recovery for neglected batteries - LED #3 steady on : Up to 16V is applied with current limited to
0,2A. If the battery is unable to accept a charge TURBO recovery will engage after 5 seconds. Batteries able to
accept 0,2A of charge current will advance to PULSE recovery.
TURBO recovery for very badly neglected batteries - LED #3 flashing: Output voltage increases to a maximum
of 22V with current limited to 0,2A.
PULSE recovery -final 15 minutes - LED #3 steady on: Current up to 0,8A is delivered in pulses to prepare the
battery to accept normal charge. This mode is particularly effective for recovery of factory activated /
“hi-performance” pure lead or cyclic cell AGM batteries.
CHARGE: LED #4
BULK charge - LED #4 steady on: A constant current of 0,8A up to a voltage of 14,2 -14,4V is delivered to the battery.
FINAL charge - LED #4 flashing: Pulsed absorption step: Current is delivered in pulses, varying between 0,2 and 0,8A and up to
a voltage of 14,2 - 14,4V, to bring the battery to full charge in the shortest possible time. Verification step: Once the current
demand is less than 0,2A the charging voltage is now limited at 13,6V whilst the battery's charge level is verified.
If the battery requires further charging the program will revert to pulsed absorption.
If the battery has accepted as much charge as its basic condition allows the voltage retention step follows.
NOTE: For safety reasons there is an overall charge time limit of 48 hours.
VOLTAGE RETENTION TEST: LED #5 flashing
Delivery of current to the battery is interrupted for 30 minutes to allow the program to determine the battery's ability to retain
charge. For batteries with a good state of health LED #5 (green) should continue to flash for the full 30 minute period. Consult the
“EARLY WARNING OF BATTERY PROBLEMS” table on page 2 for LED indications other than LED #5 (green).
A significant problem exists if the battery is unable to retain sufficient charge during the 30 minute test period. Read the section
NOTES ON TEST RESULTS on reasons for poor test results or how to test a battery that returns a good result but cannot deliver
sufficient power once it is returned to service.
MAINTENANCE CHARGE: LED #5 / 6 / 7 steady on
For 30 minutes the circuit offers current to the battery within a safe 13,6V voltage limit whilst the result of the voltage retention
test is displayed. Consult the “EARLY WARNING OF BATTERY PROBLEMS” table on page 2 for LED indications other than LED
#5 (green). The 30 minute float charge maintenance periods follow and alternate wih the 30 minute VOLTAGE RETENTION TEST
periods until the battery is disconnected. A more detailed description of the automatic maintenance cycle for long term battery
storage can be found under the section AUTOMATIC BATTERY MAINTENANCE.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Tecmate OPTIMATE 4 TM140DUAL bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Tecmate OPTIMATE 4 TM140DUAL in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Zweeds als bijlage per email.

De handleiding is 2,62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info