31
POSITIONING THE THERMO-HYGRO TRANSMITTER
Mounting at a sheltered place. Avoid direct rain and sunshine.
The thermo-hygro transmitter can be placed onto any flat surface or wall
mount using the bracket which doubles as a stand or wall mount base.
To wall mount:
1. Secure the bracket onto a desired wall using the screws and plastic
anchors.
2. Clip the transmitter onto the bracket.
Note:
Before permanently fixing the thermo-hygro to the wall base, pace all units in the desired
locations to check that the outdoor temperature and humidity readings are receivable. In
event that the signal is not received, relocate the thermo-hygro transmitter or the weather
station slightly as this may help the signal reception.
CARE AND MAINTENANCE
•
Extreme temperatures, vibration and shock should be avoided as these may cause
damage to the unit and give inaccurate forecasts and readings.
•
When cleaning the display and casings, use a soft damp cloth only. Do not use
solvents or scouring agents as they may mark the LCD and casings.
•
Do not submerge the unit in water.
•
Immediately remove all low powered batteries to avoid leakage and damage. Replace
only with new batteries of the recommended type.
•
Do not make any repair attempts to the unit. Return them to their original point of
purchase for repair by a qualified engineer. Opening and tampering with the unit may
invalidate their guarantee.
•
Do not expose the units to extreme and sudden temperature changes, this may lead to
rapid changes in forecasts and readings and thereby reduce their accuracy.
Troubleshooting
When no sensor readings are displayed in the app, check if the green LED on the gateway is
permanently lit. If not, please check if:
- The gateway is properly connected to the power plug, the router and is turned on.
- Restart the station by removing the batteries for a minute and reinserting, to restart the device.
- Your phone is connected to the internet.
- The signal is weakened by thick walls and ceilings. Put the device in operation near the gateway
and then locate a suitable location.
More information and detailed instructions can be found in the app at “Info” or at
www.mobile-alerts.eu
Techno Trade Import Export GmbH, hereby declares that the devices MA 10920 and TX29TH-IT are
in compliance with the essential requirements of directive
2014/53 / EU.
The declaration of Conformity can be found at: www.mobile-alerts.eu/technoline/doc
SPECIFICATIONS
Temperature measuring range:
Indoor: -9.9ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range)
Outdoor: -39.9ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range, “---“
displayed if no transmitter signal)
Humidity measuring range:
Indoor/outdoor humidity range : 1% to 99% with 1% resolution
(Display “- -“ if temperature is OL.F; display “1%“ if < 1%
and “99%” if > 99%)
Data checking intervals:
Indoor temperature checking interval: every 16 seconds
Outdoor temperature reception : every 4 seconds
Transmission to Gateway : every 7 minutes
Transmission range : up to 100 meters (open space)
Power consumption (alkaline batteries recommended):
Weather station : DC 5V, 150mA adapter
2 x AA, IEC, LR6, 1.5V (Back-up only)
Transmitter : 2 x AA, IEC, LR6, 1.5V
Dimensions (L x W x H):
Weather station : 148 x 32 x 115 mm
Transmitter : 38.2 x 21.2 x 128.3 mm
LIABILITY DISCLAIMER:
•
The electrical and electronic wastes contain hazardous substances. Disposal of
electronic waste in wild country and/or in unauthorized grounds strongly damages the
environment.
•
Please contact your local and/or regional authorities to retrieve the addresses of legal
dumping grounds with selective collection.
•
All electronic instruments must from now on be recycled. User shall take an active part
in the reuse, recycling and recovery of the electrical and electronic waste.
•
The unrestricted disposal of electronic waste may do harm on public health and the
quality of environment.
•
As stated on the gift box and labeled on the product, reading the “User manual” is
highly recommended for the benefit of the user. This product must however not be
thrown in general rubbish collection points.
•
The manufacturer and supplier cannot accept any responsibility for any incorrect
readings and any consequences that occur should an inaccurate reading take place.
•
This product is designed for use in the home only as indication of the temperature.
•
This product is not to be used for medical purposes or for public information.
•
The specifications of this product may change without prior notice.
•
This product is not a toy. Keep out of the reach of children.
•
No part of this manual may be reproduced without written authorization of the
manufacturer.
Old batteries do not belong into general household waste. You are obliged to return used
batteries to your vendor or collection points
Electrical devices have to be disposed separately from the general household waste. Take
your old electronics to your local waste collection point or recycling centre.