EnglishEnglish
22 23
LED 007 - background light
Auto / ON / OFF
BEEP 008 - beep tone
ON / OFF; acoustic confirmation of each key entry
KEYBO 010 - key lock
MANUAL / AUTO (automatic activation after appr. 20 seconds)
All keys, except the PTT key (9) and the FUN key (8), are deactivated with the key
lock function.
The active state is is indicated by the key symbol in the upper left corner.
TOT 011 - time out timer
Off / 30s - 270s in 30-second-steps
Transmission will be stopped automatically after set TOT time.
SCANS 012 - channel scan types
there are three scan types availabe
TO : Time-Operated-Scan
scanning stops for a certain time on an occupied channel and
then continous, regardless if further signals are received on this
channel or not.
CO : Carrier-Operated-Scan
once an occupied channel is found, scanning stops until the
signal ends, then scanning continous.
SE : Search-Scan - einfacher Kanalsuchlauf
scanning stops as soon as an occupied channel has been detected.
VOICE 013 - voice annunciation
OFF / English
activates the english voice annuncation
C-CDC 015 - CTCSS/DCS codes for transmission and reception frequencies
OFF / 50 CTCSS / 104 DCS codes*
R-CDC 016 - CTCSS/DCS codes for reception frequencies
OFF / 50 CTCSS / 104 DCS codes*
T-CDC 017 - CTCSS/DCS codes for transission frequencies
OFF / 50 CTCSS / 104 DCS codes*
* = Depending on the software programming, either CTCSS or DCS codes are dis-
played. If no coding is selected, CTCSS codes are displayed.
MENU
The following settings are managed in the menu. For changes please follow these
steps:
1. Open the menu by pressing the menu key (12).
2. For selection of the functions use the rotary channel selector (3).
3. Activate your selection by pressing the ENT key (13).
4. Select the setting with the rotary channel selector (3) and confirm by pressing the
ENT key (13).
5. Exit the menu by pressing the VFO/MR key (14).
SCAN 001 - channel scan
Start the channel scan by pressing the ENT key (12). All channels that are acti-
vated for channel scanning (via software) will be part of the channel scan list.
PRI 002 - priority channel scan
After selecting the function priority scan 001, start the priority channel scan by
pressing the ENT key (12).
Between any channel of the channel scan list, the priority channel, which is set via
software, is added. The channel order of the regular scan list 1 - 2 - 4 - 5 - 7 - 8
will change, with the priority channel no. 4, to 4 -1- 4 - 2 - 4 - 5- 4 - 7- 4 - 8.
VOX 003 - voice operated transmission
Gain Level
VOX sensitivity
settings: level 1 - 9; level 9 refers to greatest sensitivity
Delay Time
remaining time in VOX mode after end of signal
settings: 1 / 2 / 3 / 4 (in seconds)
POW 004 - power setting
H= high tx power
L= low tx power
with the PMR and FreeNet version, the high tx power is 500 mW, the low tx power
approximately 300 mW.
With the commercial versions UHF- / VHF-COM, the values for tx powers Hand L
can be programmed according to the tx power as stated in the permit.
SQL 005 - squelch
0-9; at the value 0, the squelch is deactivated; at the level 9, the highest sensiti-
vity is set.