Error messages
53
Solution
1 Check the cable and plug contacts in
the computer and the mag unit. They
could be dirty, oxidised or bent
2 The Basic works properly between
220 and 230 V/50Hz.
3 The lid of the mag unit should be
replaced
4 The print plate should be replaced
1 Replace the chain
2 Make sure the rear tyre pressure is
good
3 The mag unit will be warm after about
three minutes of cycling
4 Usethe Basic at ambient temperatures
between 5º C and 35º C (40ºF & 95º)
1 Connect the sensor or install a good
magnet
2 Make sure, the distance between the
sensor and the magnet is about 3 mm
3 Connect a new sensor
4 Check whether the plug is completely
in the connection
1 Check the cable and the plug contacts
in the computer and the unit. They
could be dirty, oxidised or bent
2 Adjust the mag unit with the adjust-
ment knob, so that the tyres cannot
slip
3 A new print plate will have to be
installed in the magnet unit
Potential problem
1 The mag unit does not brake
properly or at all
2 The mains voltage is too low
3 Several magnets of the mag
unit are loose due to having
been dropped
4 The print plate of the mag
unit is burned out
1 The bike chain is worn
2 Tyre pressure is too low
3 The mag unit is not yet warm
4 The ambient temperature is
too low
1 The cadence sensor has not
been connected or the
magnet has fallen out of the
magnet holder
2 The sensor was installed out
of range of the magnet
3 There is a break in the
cadence sensor cable
4 The sensor plug is not con-
nected properly to the mag
unit
1 The speed impulses do not
reach the computer
2 The bike wheel does not
reach the mag unit roller
3 The speed sensor in the mag
unit is defective
Failure
6 Cycling power
seems less than
shown on the display
7 Cycling power
seems higher than
shown on the display
8 The pedalling
frequency remains
zero
9 The cycle speed
remains zero
GB