SETTINGS AND MENUS - FIG. 6
The Setting mode is entered by pressing
(II) button, which visualizes the main menu (1). Scrolling in the menu is
performed by ▲ and ▼ buttons. To enter the current setting press (VIII)
button. After the screen with relevant setting is displayed, individual
parameters contained therein are adjusted as follows:
џThe current parameter is displayed enclosed in a blue rectangle (2).
Parameters are toggled with and or and buttons.
џPressing (VIII) button enters a current parameter adjustment mode
(3), whereby its value is displayed in a red rectangular. In this mode,
and buttons may change the parameter value.
џAfter the required value is selected press (VIII) button to confirm the
change and exit the parameter adjustment mode.
џParameters in the form of ticks (4) can be changed by pressing (VIII)
button, which directly changes the tick status (enabled/disabled).
After all parameters are set, changes are confirmed by pressing (VII) button,
whereby the controller returns to the main menu containing the following
settings:
џTime and date (5)sets date and time of the controller. Moreover, it
controls the automatic synchronization function where a WiFi module
is available.
џLanguage (6) sets the language in which all messages are
displayed on the screen of the controller.
џDisplay (7)changes display brightness and dims by reducing the
brightness, 30 seconds after the last time a button is pressed.
џTimer1-7 (8) adjusts the week program timer operation. For each
timer it is necessary to enter the beginning and end of the interval, to
specify in which week days to operate and the maximum heating
temperature of the water when the current moment is within the
interval.
ATTENTION! In order to use a timer it must be activated! When entering
a beginning and end of the interval, it must be taken into account that the
thermoregulator will not allow for the end to precede the beginning!
џStart time of “day” and “night” tariffs (9) sets the start time of both
tariffs, for which the controller maintains energy meters.
ATTENTION! To enable correct functioning of Smart Control mode, the
start times of both tariffs must be entered properly!
џSystem settings (10) – sets a mode, mounting position of the water
heater (horizontal or vertical), heater power, water heater capacity,
activation of the Anti-Legionella function and concurrent operation of
both heating elements (Fast Heating). Upon selection of the
‘Horizontal’ field, after exiting the menu, the screen will rotate
horizontally with right-side buttons. If the ‘Fast Heating’ field is
selected, the concurrent operation of both heating elements will be
permitted. If that field is not selected and there are conditions to switch
on the two heating elements, the element of the outlet water tank will
switch on first and after it switches off the heating element of the inlet
tank.
ATTENTION! For the proper metering of energy consumed and correct
functioning of Smart Control mode, it is essential that the heating
element power and water tank volume are properly set.
џSmart Control (11) – fine adjustment of control algorithms for Smart
Control mode. The ‘Priority’ field sets the energy saving method:
priority use of the cheaper night tariff, when the ‘Night Tariff’ is
selected, or use of pre-learned schedule of water consumption during
the week, when the ‘Consumption schedule’ is selected.
When the ‘Seasonal’ switch is activated it allows for extra heating of water
during cold season. This option compensates the need for more hot water
during winter due to the lower temperature of cold water and more heat
losses due to colder environment and walls in the room where the water
heater is installed. It is recommended to turn on that switch.
The ‘Operation Mode’ field is under the ‘Seasonal’ switch. Fine adjustment
of the temperature is carried out through it when priority is given to ‘Night
Tariff’. The more economical the mode, the lower the temperature of water
heating. Possible alternatives are ‘Eco Heating’, which is the most
economical mode, and ‘Normal Heating’ and ‘Powerful Heating’.
The EN 814 switch has an effect in ’Consumption Schedule’ priority only. It
coordinates more completely the controller operation with the requirements
of EN 814/2013 Directive that is applicable to the water heater. Since that
directive stipulates requirements for achievement of higher minimum
temperatures than those required for normal operations that will surely
increase heat losses. It is recommended to turn off that switch.
џNew WiFi network (12)initializes the WiFi module, if installed, to
switch to Access Point (AP) mode, by which the thermoregulator can
be connected to a WiFi network. With the pressing of (VIII) button the
modem will switch to Access Point mode, which means that it will
create a new WiFi network. The controller will show a display with the
name of the network and will read ‘Successful!’ when the network is
completely ready (13). Following the creation of a new WiFi network
the module may be connected to a phone, tablet or PC that will
connected the module to an Internet network to enable the remote
control and monitoring of the appliance operation. This is described in
the additional booklet provided in the packaging of the appliance
package.
OPERATION MODES - FIG. 7
The selection of an operation mode is made by pressing button (I), which
calls menu (1). The appropriate mode is selected by ▲ or ▼ buttons, and
the selection is confirmed by (VIII) button. Five seconds after a button is last
pressed, the mode selection menu is exited without changing the mode.
ATTENTION! ‘Timers’ mode cannot be selected, if there is no at least
one timer activated and the clock is not set to correct time. Smart Control
and Self-learning modes cannot be selected, if the clock is not set to
correct time.
‘Standby’ mode (2)
It turns off all active operations of the water heater. In this mode, only the
Anti-freezing mode and the Delayed start option are maintained.
‘Heating’ mode (3)
The thermoregulator will heat the water up to the preset temperature. The
temperature is set by pressing button (X). The preset temperature is
displayed in the middle of the screen. Subsequent pressing of buttons
changes the setting as desired. If no button is pressed by 10 seconds, the
new setting will be saved and the main screen is displayed. If you hold any of
or buttons longer than 0.7 sec, the value of the preset temperature will
be automatically increased or decreased with a rate of 4 units per second.
Temperature control limits are 35-75°C (12).
NOTE! While the water heater is in this mode, there is an option for
forced water heating to the maximum temperature (POWERFUL
submode) by pressing and holding (XI) button for more than 2 sec. (8) In
this submode, the two heating elements will operate irrespective of the
status of ‘Fast Hearing’ switch in ‘System Settings’ menu. Forced water
heating will turn off automatically when the two water tanks are heated up
to the required temperature. Then, it will be proceeded to normal mode
operation.
Smart Control mode (4)-(9)
Automatically determines the temperature to which water is heated up at
any moment. The purpose is to ensure sufficient quantity of hot water where
it is necessary. Where no hot water is necessary, heating will be minimal in
order to reduce energy costs. There are two options. The setting for the
heating method is made in ‘Smart Control’ submenu of the main menu,
‘Priority’ line.
џHeating with learning user consumption habits and weekly hot
water consumption schedule. Mode repeated every subsequent
week. When selecting ‘Consumption Schedule’ priority, you need to
activate the ‘Self-learning’ mode through ‘Mode Selection’ menu (1).
Then, for seven full days, the water heater will monitor and save the
time for using hot water and its quantity. Upon passing the self-
learning cycle water will be heated up to a higher temperature, saved
hot water consumption data. During other periods a minimum
temperature of 40оC will be maintained. To make full use of the energy
saving options of this method, you need to use hot water in similar
times and quantities as during self-learning. Variation in time of hot
water use of more than half an hour and/or using a different quantity of
hot water than that during the self-learning period will result in reduced
energy savings.
NOTE! If ‘Smart Control’ mode is activates with ‘Consumption Schedule’
priority and the full seven-day self-learning cycle has not yet passed, it
will be started automatically (6). When the self-learning cycle is
completed, it will automatically proceed to ‘Smart Control’ mode with
‘Consumption Schedule’ priority.
џHeating with using a second ‘cheap’ electricity tariff. When
selecting the ‘Night Tariff’ priority (5), the advantages of the lower
EN EN
12
12

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TTulpe Smart Master DV060D bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TTulpe Smart Master DV060D in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 1.2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info