When initially installing the device, qualified persons must
perform the following tests:
-Check that the internal and external parts of the gas supplying
device are sealed.
Check that the gas quantity supplied is equal to that required by
the device.
-
-
Check that the device receives the type of gas it is
manufactured to process.
Check that the gas supply pressure does not go beyond the
maximum pressure values displayed on the information plate.
- Check that the gas supply system supplies the necessary amoun
t of gas to the device and that it is equipped with all the
necessary safety devices prescribed by current regulations.
If the user is absent for a lengthy period, turn off the main gas
supply tap.
Do not obstruct the area sventilation openings where the device is
installed to avoid dangers such as the build-up of toxic and
explosive substances. Do not utilize gas tubes to earth electrical
devices. Water connection Connect the water heater to the
water supply and insert a tap to int ercept the water above the
device. From the front, the cold-water i nput is on the right and the
hot water output is on the left.
Insert the filter into the water valve input fitting.
Remove the plastic nut from the hot water output fit in before
connecting it to the water supply.
Check the water hardness f).
In case of high water hardness, we recommend
installing upstream of the appliance the water softener
device or oth er device in compliance with the regulations
including any re visions.
Ensure that the tubes of your water system are not used to
earth your electrical system or telephone, they are inappropriate
for p erforming this task.
In a short amount of time this can damage tubes and the device.
Disposal of waste product
This B11BS water heater is supplied with a device for releasing
flue gas.
For output of combustion by-products refer to the regulations in
force including any updates.
The gas devices with an attachment for a waste gas flue must be
connected directly to properly working chimney or flue pipe; only if
these devices are not present is it then permitted to release
gases directly outside.
The fitting of devices to a chimney or flue pipe must occur via a
smoke channel. Smoke channels must be connected to a
chimney or a smoke channel in the same or adjacent area to
where the device is installed and must be made of materials
resistant to mechanical strain, heat and the effects of combustion
by-product s and their condensation. The flue gas temperature
must always be above condensation temperature in all points of the
smoke chan nel regardless of external conditions.
FLUE GAS RELEASE SAFETY DEVICE
The product is equipped with a series of flue gas release safety
devices. The device ensures the correct release of combustion by -
products, the flow of combustible gas to the release conduit
and the smoke channel.
The safety device contains a thermostat ,it can stop the flow of
gas to the main burner and the pilot flame.
The safety device can be triggered by the partial or total obstruction
of the release conduit or the smoke channel.
Whenthe temperatureof thermostatresumeto normal,removethe fault
codeaccordingto the Fault Code Solution. Thenturnon the tap again.
If the device or its electrical connections breaks down, the product
cannot be put ON, it ensures a safe condition
If the device or its electrical connections breaks down, the machine
operation is blocked.
If the machine is constantly blocked because of the flue gas
safety device, it is necessary to request the assistance of a
qualified te chnician according
to law in force, to che
ck the correct releas
e of flue gas through
the release conduit
and/or the smoke ch
annel,ac-cording to
the installation regul
OPERATION
High water temperature
A-ON/OFFbutton
B-UP button
C-DOWN button
ation.
It is highly prohibited
to attempt to modify
or remove the flue g Fig.6
as safety device; thi
s risks the safety of
the user and persons in the area. Only a qualified technician who is
authorized by the manufacturer can meddle with the safety devic
e to check its functionality or to substitute it if necessary.
If it is necessary to replace the device, it is vital to only use original
partssupplied by the manufacturer since it has been designed,
studied, and regulated to be fitted with the water heater.
Fig.7Fig.8
Low water temperature
148.00 mm
210.00 mm
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw TTulpe Indoor B-10 N25Eco bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van TTulpe Indoor B-10 N25Eco in de taal/talen: Engels als bijlage per email.

De handleiding is 6.19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van TTulpe Indoor B-10 N25Eco

TTulpe Indoor B-10 N25Eco Gebruiksaanwijzing en installatiehandleiding - Nederlands - 12 pagina's

TTulpe Indoor B-10 N25Eco Gebruiksaanwijzing en installatiehandleiding - Deutsch - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info